• 제목/요약/키워드: Reducing Building Energy

검색결과 253건 처리시간 0.027초

Semi-active structural fuzzy control with MR dampers subjected to near-fault ground motions having forward directivity and fling step

  • Ghaffarzadeh, Hosein
    • Smart Structures and Systems
    • /
    • 제12권6호
    • /
    • pp.595-617
    • /
    • 2013
  • Semi-active control equipments are used to effectually enhance the seismic behavior of structures. Magneto-rheological (MR) dampers are semi-active devices that can be utilized to control the response of structures during seismic loads and have received voracious attention for response suppression. They supply the adaptability of active devices and stability and reliability of passive devices. This paper presents an optimal fuzzy logic control scheme for vibration mitigation of buildings using magneto-rheological dampers subjected to near-fault ground motions. Near-fault features including a directivity pulse in the fault-normal direction and a fling step in the fault-parallel direction are considered in the requisite ground motion records. The membership functions and fuzzy rules of fuzzy controller were optimized by genetic algorithm (GA). Numerical study is performed to analyze the influences of near-fault ground motions on a building that is equipped with MR dampers. Considering the uncontrolled system response as the base line, the proposed method is scrutinized by analogy with that of a conventional maximum dissipation energy (MED) controller to accentuate the effectiveness of the fuzzy logic algorithm. Results reveal that the fuzzy logic controllers can efficiently improve the structural responses and MR dampers are quite promising for reducing seismic responses during near-fault earthquakes.

농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 - (The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data -)

  • 윤영일;송정석;이효원
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

A water treatment case study for quantifying model performance with multilevel flow modeling

  • Nielsen, Emil K.;Bram, Mads V.;Frutiger, Jerome;Sin, Gurkan;Lind, Morten
    • Nuclear Engineering and Technology
    • /
    • 제50권4호
    • /
    • pp.532-541
    • /
    • 2018
  • Decision support systems are a key focus of research on developing control rooms to aid operators in making reliable decisions and reducing incidents caused by human errors. For this purpose, models of complex systems can be developed to diagnose causes or consequences for specific alarms. Models applied in safety systems of complex and safety-critical systems require rigorous and reliable model building and testing. Multilevel flow modeling is a qualitative and discrete method for diagnosing faults and has previously only been validated by subjective and qualitative means. To ensure reliability during operation, this work aims to synthesize a procedure to measure model performance according to diagnostic requirements. A simple procedure is proposed for validating and evaluating the concept of multilevel flow modeling. For this purpose, expert statements, dynamic process simulations, and pilot plant experiments are used for validation of simple multilevel flow modeling models of a hydrocyclone unit for oil removal from produced water.

Oncogene-Driven Metabolic Alterations in Cancer

  • Min, Hye-Young;Lee, Ho-Young
    • Biomolecules & Therapeutics
    • /
    • 제26권1호
    • /
    • pp.45-56
    • /
    • 2018
  • Cancer is the leading cause of human deaths worldwide. Understanding the biology underlying the evolution of cancer is important for reducing the economic and social burden of cancer. In addition to genetic aberrations, recent studies demonstrate metabolic rewiring, such as aerobic glycolysis, glutamine dependency, accumulation of intermediates of glycolysis, and upregulation of lipid and amino acid synthesis, in several types of cancer to support their high demands on nutrients for building blocks and energy production. Moreover, oncogenic mutations are known to be associated with metabolic reprogramming in cancer, and these overall changes collectively influence tumor-microenvironment interactions and cancer progression. Accordingly, several agents targeting metabolic alterations in cancer have been extensively evaluated in preclinical and clinical settings. Additionally, metabolic reprogramming is considered a novel target to control cancers harboring un-targetable oncogenic alterations such as KRAS. Focusing on lung cancer, here, we highlight recent findings regarding metabolic rewiring in cancer, its association with oncogenic alterations, and therapeutic strategies to control deregulated metabolism in cancer.

Thin Films for Environmental Application and Energy Devices

  • Kim, Young-Dok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.91-91
    • /
    • 2012
  • We aim in synthesizing various functional thin films thinner than ~ 10 nm for environmental applications and photovoltaic devices. Atomic layer deposition is used for synthesizing inorganic thin films with a precise control of the film thickness. Several examples about application of our thin films for removing volatile organic compounds (VOC) will be highlighted, which are summarized in the below. 1) $TiO_2$ thin films prepared by ALD at low temperature ($<100^{\circ}C$) show high adsorption capacity for toluene. In combination with nanostructured templates, $TiO_2$ thin films can be used as building-block of high-performing VOC filter. 2) $TiO_2$ thin films on carbon fibers and nanodiamonds annealed at high temperatures are active for photocatalytic oxidation of VOCs, i.e. photocatalytic filter can be created by atomic layer deposition. 3) NiO can catalyze oxidation of toluene to $CO_2$ and $H_2O$ at $<300^{\circ}C$. $TiO_2$ thin films on NiO can reduce poisoning of NiO surfaces by reaction intermediates below $200^{\circ}C$. We also fabricated inverted organic solar cell based on ZnO electron collecting layers on ITO. $TiO_2$ thin films with a mean diameter less than 3 nm on ZnO can enhance photovoltaic performance by reducing electron-hole recombination on ZnO surfaces.

  • PDF

요양시설의 유용조도 분석에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로- (The Study on the Analysis of Useful Daylight Illuminance in Care Facilities - By Dynamic Daylight Simulation Using Weather Data -)

  • 윤영일;조주영;이효원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제17권1호
    • /
    • pp.33-40
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the care facility design process, because of lack of previous studies on elderly- light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

Development of Optical Fiber-based Daylighting System with Uniform Illumination

  • Ullah, Irfan;Shin, Seoyong
    • Journal of the Optical Society of Korea
    • /
    • 제16권3호
    • /
    • pp.247-255
    • /
    • 2012
  • Daylighting has a very effective role in reducing power consumption and improving indoor environments in office buildings. Previously, it was not under consideration as a major source of renewable energy due to poor reliability in the design. Optical fiber as a transmission medium in the daylighting system demands uniform distribution of light to solve cost, heat, and efficiency issues. Therefore, this study focuses on the uniform distribution of sunlight through the fiber bundle and to the interior of the building. To this end, two efficient approaches for the fiber-based daylighting system are presented. The first approach consists of a parabolic mirror, and the second approach contains a Fresnel lens. Sunlight is captured, guided, and distributed through the concentrator, optical fibers, and lenses, respectively. At the capturing stage, uniform illumination solves the heat problem, which has critical importance in making the system cost-effective by introducing plastic optical fibers. The efficiency of the system is increased by collimated light, which helps to insert maximum light into the optical fibers. Furthermore, we find that the hybrid system of combining sunlight and light emitting diode light gives better illumination levels than that of traditional lighting systems. Simulation and experimental results have shown that the efficiency of the system is better than previous fiber-based daylighting systems.

환기부족 구획화재의 열적 특성 (Thermal Characteristics of Under Ventilated Compartment Fire)

  • 김성찬
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.41-48
    • /
    • 2009
  • The present study has been performed to investigate the thermal characteristics of under-ventilated compartment fire which is a typical fire condition in structures. A series of fire experiments was conducted to characterize the thermally driven flow in a 2/5 scale ISO 9705 fire compartment. Three different fuels were used in this test series, methane gas, heptane pool, and polystyrene pellets fire. In order to measure accurate temperature, double shield aspirated thermocouples reducing the effect of radiative energy exchange on temperature measurement were used in addition to bare bead thermocouples. The upper layer temperature for well ventilated fire was increased with increasing heat release rate, but it was slightly decreased for under-ventilated fire. The measured temperatures in the upper layer at the front sampling location were higher than at the rear. Thermal characteristics through the doorway were also analysed for a wide range of heat release rates. This study provides a comprehensive and quantitative assessment of fire behavior for under-ventilation condition of fire.

Behavior of composite CFST beam-steel column joints

  • Eom, Soon-Sub;Vu, Quang-Viet;Choi, Ji-Hun;Papazafeiropoulos, George;Kim, Seung-Eock
    • Steel and Composite Structures
    • /
    • 제32권5호
    • /
    • pp.583-594
    • /
    • 2019
  • In recent years, composite concrete-filled steel tubular (CFST) members have been widely utilized in framed building structures like beams, columns, and beam-columns since they have significant advantages such as reducing construction time, improving the seismic performance, and possessing high ductility, strength, and energy absorbing capacity. This paper presents a new composite joint - the composite CFST beam-column joint in which the CFST member is used as the beam. The main components of the proposed composite joint are steel H-beams, CFST beams welded with the steel H-column, and a reinforced concrete slab. The steel H-beams and CFST beams are connected with the concrete slab using shear connectors to ensure composite action between them. The structural performance of the proposed composite joint was evaluated through an experimental investigation. A three-dimensional (3D) finite element (FE) model was developed to simulate this composite joint using the ABAQUS/Explicit software, and the accuracy of the FE model was verified with the relevant experimental results. In addition, a number of parametric studies were made to examine the effects of the steel box beam thickness, concrete compressive strength, steel yield strength, and reinforcement ratio in the concrete slab on the proposed joint performance.

축전지 사용 유무에 따른 태양광발전기의 성능 분석 (Performance Analysis of Photovoltaic Power Generator by Usage Battery Charge)

  • 윤성욱;최만권;김현태;윤용철
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.220-227
    • /
    • 2013
  • 본 연구는 온실 운영에 필요한 전력량을 확보함으로서 온실경영비 절감을 목적으로 태양광발전시스템을 온실에 인접한 건물의 옥상에 설치하여 일사량에 따른 발전량을 실험적으로 검토하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 수평면 일사량의 최대, 평균 및 최소값은 각각 $26.1MJ{\cdot}m^{-2}$, $14.0MJ{\cdot}m^{-2}$$0.6MJ{\cdot}m^{-2}$ 정도였고, 일일 전력량은 각각 약 6.1kWh, 3.7kWh 및 0.01kWh 이었다. 그리고 누계 일사량과 전력량은 각각 약 $4,378.2MJ{\cdot}m^{-2}$ 및 1,163.2kWh 정도이었다. 그리고 부하에 의해 소비된 적산전력량의 최대, 평균 및 최소값은 각각 4.5kWh, 2.4kWh 및 0.0kWh 정도이었고, 누계전력량은 739.2kWh 정도로서 발생 전력량의 약 63.5%에 해당하였다. 본 실험에 사용된 시스템의 평균 소비전력량을 기준으로 보면, 온풍기의 용량 및 작동시간이 작은 경우는 충분하지만 큰 경우는 부족한 것으로 나타났다. 어레이 표면온도가 상대적으로 높아지면 일사량에 비례해서 발생 전력이 증가하지 않은 것으로 나타났지만, 두 인자 간에 상관계수는 0.851 정도로서 상관관계가 높은 것으로 나타났다.