• Title/Summary/Keyword: Reduced scale test

Search Result 490, Processing Time 0.032 seconds

A Study on the Comparison of the Rolling and Resistance Performance for the Stepped-Hull with attached a Stern-body by using Sea Model-Test (실 해상모형시험을 이용한 선미 보조동체 장착 Stepped hull 선형의 횡동요 및 저항특성 비교 연구)

  • Jo, Hyo-Jae;Sohn, Kyoung-Ho;Park, Chung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.813-818
    • /
    • 2007
  • There are the C.W.C and Towing Tank to the model-test equipments of the boat. A model testing of the high speed boat have a difficult in the performance verification because of very a small the scale-ratio of the ship-model and restricted by flow-velocity of the C.W.C and X-carriage velocity of the T.T. In general, the stepped hull boat is a high of fuel-efficiency because of the resistance reduction by a small wetted surface-area in correspond without stepped-hull boat. But It have a tendency to be bad the rolling performance by reduced stern wetted-area In this paper, the high speed stepped planning-boats with & without attached a stern body were performed to compare the effect of resistance and rolling performance by using sea model-test method.

Seismic Performance and Flexural Over-strength of Circular RC Column (원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.49-58
    • /
    • 2013
  • Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with constant axial load. Test specimens were designed with 4.5 aspect ratio. The selected test variables are longitudinal steel ratio, transverse steel ratio, yielding strength of longitudinal steel and axial load ratio. The test results of columns with different longitudinal steel ratio, transverse steel ratio and axial load ratio showed different seismic performance such as equivalent damping ratio, residual displacement and effective stiffness. It was found that the column with low strength of longitudinal steel showed significantly reduced seismic performance, especially for equivalent damping ratio and residual displacement. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications (Limited state design).

Exercise Using Isokinetic Strength Training Equipment and Physical Function Improvement

  • Hyon-Min Tae;Su-Yeong Eom;Byoung-Kwon Lee;Dae-Sung Park
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.8-17
    • /
    • 2024
  • Objective: This study aims to explore the relationship between isokinetic strength training and the enhancement of physical function in older adults. It also evaluates the effectiveness of isokinetic strength training equipment. Method: This study randomly divided twenty healthy adults into two groups.The experimental group engaged in isokinetic strength training for 30 minutes, three times a week, over a four-week period. In contrast, the control group did not participate in any exercise regimen. We assessed several outcome measures including physical functions (sit-to-stand test, flexibility, Timed Up and Go test), grip strength, balance, thigh circumference, the Korean version of the Patient Health Questionnaire-9 (PHQ-9), and the Korean version of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Additionally, the experimental group's self-perceived improvement in lower limb condition was evaluated using the Global Rating of Change (GROC) scale. Results: The experimental group showed significant improvements compared to the control group in various aspects: reduced sit-to-stand test duration (7.00±2.05 seconds), increased flexibility (4.69±3.90 cm), improved grip strength (1.54±1.74 kg), increased thigh circumference (left: 1.29±1.19 cm, right: 1.19±1.27 cm), enhanced Timed Up and Go test performance (-1.47±0.86 seconds), better balance (eyes open stance: -8.08±4.03 cm, eyes closed stance: -0.27±0.13 cm/s), and a decrease in depression severity (-0.15±1.51 points). Furthermore, significant increases were observed in the experimental group's maximal isokinetic strength at 90°/s for both flexion (19.62±7.03 Nm) and extension (19.60±14.65 Nm) over the study period. Conclusion: The findings suggest that isokinetic strength training equipment can significantly enhance physical functions in seniors when incorporated into an exercise regimen.

Intravenous caffeine citrate vs. magnesium sulfate for reducing pain in patients with acute migraine headache; a prospective quasi-experimental study

  • Baratloo, Alireza;Mirbaha, Sahar;Kasmaei, Hossein Delavar;Payandemehr, Pooya;Elmaraezy, Ahmed;Negida, Ahmed
    • The Korean Journal of Pain
    • /
    • v.30 no.3
    • /
    • pp.176-182
    • /
    • 2017
  • Background: Current evidence suggests that intravenous magnesium sulfate might be effective for reducing migraine pain. In a recent pilot study, we showed that intravenous caffeine citrate could reduce the severity of migraine headache. The objective of this study is to investigate the efficacy of intravenous caffeine citrate vs. magnesium sulfate for management of acute migraine headache. Methods: We conducted a prospective quasi-experimental study from January until May 2016 in two educational medical centers of Shahid Beheshti University of Medical Sciences (Shoahadaye Tajrish Hospital and Imam Hossein Hospital), Tehran, Iran. The study included patients who were referred to the emergency department and met the migraine diagnosis criteria of the International Headache Society. Patients were allocated into 2 groups receiving either 60 mg intravenous caffeine or 2 g intravenous magnesium sulfate. The pain scores, based on the visual analog scale, were recorded on admission, as well as one and two hours after receiving the drug. A Chi-Square test and student t-test were used for analysis of baseline characteristics. A Mann-Whitney U test and Wilcoxon singed rank test were used to analyze differences in the visual analogue scale (VAS) score between and within the groups respectively. Results: In total, 70 patients (35 patients in each group) with the mean age of $33.1{\pm}11.3years$ were included (64.3% female). For the Caffeine citrate group, the median pain score decreased from 9.0 (2.0) to 5.0 (4.0) after one hour and to 3.0 (4.0) after two hours. For the magnesium sulfate group, the pain score decreased from 8.0 (2.0) to 2.0 (2.0) after one hour and to 0.0 (1.0) after two hours. Both intravenous caffeine citrate and intravenous magnesium sulfate reduced pain scores significantly but the magnesium sulfate group showed more improvement than the Caffeine citrate group after one hour (P < 0.001) and after two hours (P < 0.001). Conclusions: It is likely that both intravenous caffeine and intravenous magnesium sulfate can reduce the severity of migraine headache. Moreover, intravenous magnesium sulfate at a dose of 2 g might be superior to intravenous caffeine citrate 60 mg for the short term management of migraine headache in emergency departments.

THE EFFECT OF A MENTAL HEALTH PROMOTION PROGRAM AT A MENTAL HEALTH MODEL MIDDLE SCHOOL (정신건강시범 중학교에서 수행된 정신건강 증진 프로그램의 효과)

  • Kwak, Young-Sook;Ko, Hey-Joung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.16 no.2
    • /
    • pp.251-260
    • /
    • 2005
  • Objectives : This study was performed to evaluate the effects of a mental health program within a mental health model middle school. Methods : Subjects of the study consisted of 748 students from the second grade and third grade students at the middle school chosen for a school mental health program by the Ministry of Education in Jeju. The subjects participated in 12 consecutive sessions of group discussion developed to prevent mental health problems. The authors investigated the effects of the program by evaluating the students with Young's Internet Addiction Scale (IAS), Conners & Wells' Adolescent Self Report Scale(CASS) and Minnesota Multiphasic Personality Inventory (MMPI) before the initial session and after the final session. The data was analyzed by t-test in SPSS PC+ 10.0. The range of significance was p<.05. Results : In MMPI, the percentage of students above clinical range reduced from $12.9\%\;to\;11.0\%$. It reduced in the second grade students, but increased in the third grade students. The scores of paranoia and mania subscales showed a statistically significant reduction. In IAS, the percentage of students above the range of Internee overuse reduced from $16.0\%\;to\;6.8\%$. The percentage of students who showed risk of attention problems in CASS reduced from $22.7\%\;to\;18.3\%$. Also, both IAS and CASS scores showed a statistically significant reduction. The clinical significance of the reduction of IAS scores was within moderate range. Conclusion : The mental health program reduced the percentage of students' risk of mental health problems, internet addiction and attention problems and it was clinically effective on preventing Internet addiction. These results support the effects of a school mental health program to promote students' mental health. The authors suggest to expand this program to other schools, to reconfirm the effect of the program by using proper & specified instruments and to evaluate long-term effect of the program.

  • PDF

Evaluating Seismic Performance of Steel Welded Moment Connections Fabricated with SN Steel (SN 강재가 사용된 강구조 용접모멘트접합부의 내진성능 평가)

  • Oh, Sang-Hoon;Choi, Young-Jae;Yoon, Sung-Kee;Lee, Dong-Gue
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.271-280
    • /
    • 2010
  • This study was programmed to fabricate a beam-to-column connection that is limited to a steel-welded moment connection with full-scale members, using SN steel. A cyclic seismic test was conducted of the nine specimens that were fabricated by choosing the test variable for the weld access hole geometry, connection design method, and RBS. From the test results, failure modes, the moment-drift behavior, and the strain distribution were provided. From the specimen material properties, the beam's nominal plastic flexural capacity and classified qualified connection as a special moment flame were calculated. By analyzing the skeleton part and the baushinger part, a range of strength-raising effects, and deformation ratios were provided, with which the seismic performance of the specimens were evaluated. The test results showed that the specimens eliminated their weld access holes that demonstrated higher seismic performance than the specimens' existing weld access holes, and that the WUF-W connection that was reinforced by the supplemental fillet weld around the shear tap that was fastened by five bolts demonstrated superior seismic performance.

A Study on the Manufacturing Characteristics and Field Applicability of Engineering-scale Bentonite Buffer Block in a High-level Nuclear Waste Repository (고준위폐기물처분장 내 공학규모의 균질 완충재 블록 성형특성 및 현장적용성 분석)

  • Kim, Jin-Seop;Yoon, Seok;Cho, Won-Jin;Choi, Young-Chul;Kim, Geon-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.1
    • /
    • pp.123-136
    • /
    • 2018
  • The objective of this study is to propose a new methodology to fabricate a reliable engineering-scale buffer block, which shows homogeneous and uniform distribution in buffer block density, for in-situ experiments. In this study, for the first time in Korea, floating die press and CIP (Cold Isostatic Press) are applied for the manufacture of an engineering-scale bentonite buffer. The optimized condition and field applicability are also evaluated with respect to the method of manufacturing the buffer blocks. It is found that the standard deviation of the densities obtained decreases noticeably and that the average dry density increases slightly. In addition, buffer size is reduced by about 5% at the same time. Through the test production, it is indicated that the stress release phenomenon decreases after the application of the CIP method, which leads to a reduction in crack generation on the surface of the buffer blocks over time. Therefore, it is confirmed that the production of homogeneous buffer blocks on industrial scale is possible using the method suggested in this study, and that the produced blocks also meet the design conditions for dry density of buffer blocks in the AKRS (Advanced Korea Reference Disposal System of HLW).

An Empirical Study on the Size Distribution of Venture Firms in the center of KOSDAQ Listed Companies (국내 벤처기업 진화과정에 관한 실증분석 - 코스닥상장 기술벤처기업 분석을 중심으로 -)

  • Cho, Sang-Sup;Yang, Young-Seok
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.6 no.1
    • /
    • pp.23-37
    • /
    • 2011
  • This paper is brought to carry out an empirical study whether evolution process of venture firm's scale is following the Gibrat's law; random evolution process, or Pareto law; self-organizing process. The empirical test, as attaching theoretical explanation, of this research utilize the serial data samples of 92 KOSDAQ listed companies from the year of 2005 through 2008. Summarizing the research results are as followed. First, Gini Coefficients representing the density of venture firm's scale has been constantly reduced since the year of 2005 in terms of number of employee, while these index increased during the same time period from the perspective of sales volume. Second, the evolution process of Korea venture firm's scale is following the Power Law related to Pareto Law. In particular, estimated Pareto coefficient, ${\alpha}$, is shown lower than 1 which is significant result. Third, the probability of joining in the top tier group of firm starting from the early stage growing is forecasted into 6.9%, the result which emphasize the starting scale of venture firm play an important role in long term evolution of venture firm.

  • PDF

Research on damage and identification of mortise-tenon joints stiffness in ancient wooden buildings based on shaking table test

  • Xue, Jianyang;Bai, Fuyu;Qi, Liangjie;Sui, Yan;Zhou, Chaofeng
    • Structural Engineering and Mechanics
    • /
    • v.65 no.5
    • /
    • pp.547-556
    • /
    • 2018
  • Based on the shaking table tests of a 1:3.52 scale one-bay and one-story ancient wooden structure, a simplified structural mechanics model was established, and the structural state equation and observation equation were deduced. Under the action of seismic waves, the damage rule of initial stiffness and yield stiffness of the joint was obtained. The force hammer percussion test and finite element calculations were carried out, and the structural response was obtained. Considering the 5% noise disturbance in the laboratory environment, the stiffness parameters of the mortise-tenon joint were identified by the partial least squares of singular value decomposition (PLS-SVD) and the Extended Kalman filter (EKF) method. The results show that dynamic and static cohesion method, PLS-SVD, and EKF method can be used to identify the damage degree of structures, and the stiffness of the mortise-tenon joints under strong earthquakes is reduced step by step. Using the proposed model, the identified error of the initial stiffness is about 0.58%-1.28%, and the error of the yield stiffness is about 0.44%-1.21%. This method has high accuracy and good applicability for identifying the initial stiffness and yield stiffness of the joints. The identification method and research results can provide a reference for monitoring and evaluating actual engineering structures.

An experimental study on the liquid rocket combustion chamber cooling (액체로켓 연소실 냉각에 관한 실험적 연구)

  • Kim, B.H.;Park, H.H.;Jeong, Y.G.;Kim, Y.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.2
    • /
    • pp.1-7
    • /
    • 2001
  • To protect combustion chamber from high temperature combustion gas, regenerative cooling is used for most liquid rocket engine. Although regenerative cooling is the most effective way to protect the chamber from high heat flux, realization of this system requires detail analysis, manufacturing technique and high cost. To demonstrate the possibility of applying regenerative cooling to a real rocket engine, the hot fire test has been carried out for the sub-scale liquid rocket with the water cooling system. The main purpose of the test is to identify the problem area of design, safety and cost effective manufacturing technique. The coolant passage was 3 mm in width and wall thickness was 1 mm with stainless steel. Maximum combustion time and pressure were 60 seconds and 400 psi, respectively. The flow rate of coolant was reduced gradually from 2 kg/s to 0.12 kg/s throughout firing test, combustion chamber was visually examined and no dwfect was observed.

  • PDF