• Title/Summary/Keyword: Reduced scale test

Search Result 486, Processing Time 0.031 seconds

Effect of Mutual Coupling Between Test Leads on Ground Impedance Measurement (측정선의 상호유도작용이 접지임피던스의 측정에 미치는 영향)

  • Lee, Bok-Hee;Eom, Ju-Hong;Cho, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.71-74
    • /
    • 2003
  • Fall-of-potential method is used usually to measure the ground impedance of large scale grounding system exactly. Because the interlinked magnetic flux between closed loops to inject test current and to measure potential rise is existed in E-P-C straight line arrangement, mutual(or inductive) coupling influences greatly on the measurement correctness. Measurement errors produced from inductive coupling could be reduced by the arrangement methods of auxiliary electrodes. Right angle or P-E-C order arrangement methods were effective to reduce the inductive coupling and the decrease degree of measurement error was analysed as quantitative through an experiment.

  • PDF

The Effect of Self-help Group Program on Adaptation and Quality of Life of Mastectomy Patients (자조집단 프로그램이 유방절제술 환자의 적응과 삶의 질에 미치는 효과)

  • Park, Young-Shin;Lim, Nan-Young
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.2 no.1
    • /
    • pp.61-71
    • /
    • 1999
  • This quasi-experimental study was intended to test the effect of self-help group program, which is one of the way to enhance adaptation and quality of life to mastectomy patients. Data was collected from July 14, 1998 to Oct. 31, 1998 at two Medical Center in Seoul. The subjects for this study were the patients who had undergone mastectomy and were follow-up ; 14 in experimental group and 14 in control group matched with age and treatment. The instruments for this study were adaptation in Lee(1994)'s physical symptom questionnaire, Zung's Self-rating Depression Scale(SDS, 1965), and Self-rating Anxiety Scale(SAS, 1970), quality of life in Spranger(1996)'s and No(1988)'s Quality of Life Questionnaire. The self-help group program for mastectomy patients was developed based on literature review and pilot study by the investigator. The subjects of experimental group were participated in 6 weeks self-help group program and were received arm and shoulder exercise, informational support, and interpersonal support by group members. The control group were received no intervention, Both group answered questionnaires prior to intervention and 6 weeks later. The data analyzed by frequency, $X^2$-test, Mann-Whitney U test. Wilcoxon Signed Rank test, Pearson's Correlation Coefficient and Stepwise Multiple Regression using SPSS WIN. The results are as follows ; Hypothesis 1. "The experimental group with the self-help group program will have a higher score on adaptation state than control group." was not supported. But the post test score of anxiety and depression in experimental group were declined and the depression score was reduced relatively. Hypothesis 2. "The experimental group with the self-help group program will have a higher score on quality of life than control group." was not supported. But the posttest score of quality of life in experimental group was reduced relatively. Hypothesis 3. "The higher adaptation state of mastectomy patients, the higher quality, of life." was supported(r=,80, p<.001). Additionally, the lower physical symptom, depression and anxiety, the higher quality of life And depression, which was the main predictor of quality of life, accounted for 59.5%, depression and anxiety accounted for 65.5% of the variance in quality of life. In conclusion, when the self-help group program was intervened to mastectomy patients, it was tended to increase quality of life and to reduce depression and anxiety. So self-help group program can be considered useful nursing inter vention effect on adaptation and quality of life of mastectomy patients. With discussion, I suggest repeated further re search on self-help group with appropriate sample size and longitudinal study. Also during adjuvant therapy, it is needed to develop convenient method to be supported from peer group and family, such as computer mediated support group.

  • PDF

A Clinical Case Report of Multiple Sclerosis Treated with Only Hominis Placental Pharmacopuncture (자하거 약침 단독치료로 호전된 다발성 경화증 치험 1례)

  • Hwang, Gyu-sang;Yu, Keun-jeong;Lee, Su-yeong;Lee, Jun-yeong;Kim, Du-ri;Hong, Ka-kyung;Shin, Sun-ho;Shin, Yong-jeen
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.2
    • /
    • pp.289-300
    • /
    • 2017
  • Objectives: This case report describes the effect of Hominis placenta pharmacopuncture (HPP) on multiple sclerosis. Methods: A multiple sclerosis patient with gait disturbances, tremors, spasms of both lower limbs, and diplopia was treated with only HPP for two weeks. To evaluate the effects of HPP on the balance ability of the patient, the Functional System (FS) scale, Expanded Disability Statue Scale (EDSS), visual analog scale (VAS), manual muscle test (MMT), and Berg Balance Scale (BBS) were used. Results: The HPP treatment reduced the patient's gait disturbance, tremors, spasms of the lower limbs, and diplopia. According to the FS scale, the patient's cerebellar and optic functions were enhanced. In addition, the patient's performance on the EDSS improved from 4.0 to 3.0.3. As shown by the MMT, the lower extremities showed a mild improvement (from F+ to G.4). Furthermore, the VAS showed a considerable improvement, decreasing from 9 to 6.5 post-treatment. The patient's performance on the BBS, which denotes balance ability, showed a considerable improvement, increasing from 38 to 49. Conclusion: Treatment with only HPP could help to ameliorate the symptoms of multiple sclerosis.

Seepage Analysis of Large-Scale Embankment Model by Revised TDR Sensor (개량된 TDR센서를 이용한 대형 모형제방의 침투 해석)

  • Park, Min-Cheol;Lee, Jong-Wook;Kim, You-Seok;Han, Heui-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.11
    • /
    • pp.53-67
    • /
    • 2012
  • In this research, stainless steel and heat-shrinkage tube were used for new TDR sensing line to solve the problems of ordinary TDR system. The new TDR line improved the sensitivity of water content and endurance, and reduced the data noise. The saturation degree test and acryl model test were done by revised TDR sensor. From the results, without additional data filtering and quantitative analysis, the raw data were separated into 3 zones; saturated, unsaturated and dried zones easily. In addition, the revised TDR sensor was installed in large-scale embankment model to perform the seepage test. The raw data of the model tests showed the distributed seepage behaviors and separated zones clearly, which were almost the same tendencies as the lab test results.

Performance Study of High-Performance Synthetic Supporting Materials by Real-Scale Tests (실대형 시험을 통한 고성능 합성지보재의 성능 고찰)

  • Kang, Tae-Ho;Chang, Soo-Ho;Choi, Soon-Wook;Lee, Chulho
    • Tunnel and Underground Space
    • /
    • v.31 no.6
    • /
    • pp.428-439
    • /
    • 2021
  • A spray-on membrane is a material composed of a polymer, and is a spray-type material that is expected to be able to replace materials such as existing shotcrete or sheet membrane for support or waterproofing purposes. In the previous studies, it is expected that the thickness of the support material such as shotcrete can be reduced if the spray-on membrane is additionally installed on the existing cement-based support materials. In this study, a three-point bending test was performed by a spray-on membrane on the high-performance shotcrete on the outside, and comparison was made between the case where high-performance shotcrete and a spray-on membrane were installed. As a result of comparing the values calculated through the standard test and the real-size bending test, there was no significant difference in terms of flexural strength, but it was found that there was a difference in flexural toughness.

Evaluation of transcutaneous electrical nerve stimulation as an adjunct therapy in trigeminal neuralgia - a randomized double-blind placebo-controlled clinical study

  • Bisla, Suman;Gupta, Ambika;Agarwal, Shalini;Singh, Harneet;Sehrawat, Ankita;Singh, Aarti
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.6
    • /
    • pp.565-574
    • /
    • 2021
  • Background: Trigeminal neuralgia (TN) is a severe form of pain that affects the daily activities of a patient. Transcutaneous electrical nerve stimulation (TENS) therapy is an emerging option for the treatment of acute and chronic pain. The aim of this study was to evaluate the effect of TENS therapy as an adjunct to drug therapy for the treatment of TN. Methods: A total of 52 patients diagnosed with TN according to the International Classification of Headache Disorders (version 3) were included. Each patient was randomized to either the TENS or placebo TENS groups. Intervention was given in continuous mode and 100-Hz frequency for 20 mins biweekly for 6 weeks. Parameters were measured at baseline, TENS completion and 3 months, 6 months, and 1 year of follow up. The parameters observed were mean carbamazepine dose, mean visual analog scale (VAS) score, mean present pain intensity (PPI) score, and functional outcome. Non-parametric analyses, one-way ANOVA and the Kruskal-Wallis test were applied for intragroup comparisons, while the Mann-Whitney U test and independent t-test were used for intergroup comparisons of variables. The chi-square test was applied to analyze categorical data. Results: Compared to the placebo TENS group, the mean dose of carbamazepine in the TENS group was significantly reduced at TENS completion, as well as at 6 months and 1 year follow up. Changes in mean VAS score, mean PPI score, and functional outcome did not show significant differences between the groups (P>0.05). Conclusion: TENS therapy does not lead to any changes in pain levels but it may reduce the mean dose of carbamazepine when used as an adjunct treatment in patients with TN.

Cyclic performance and design recommendations of a novel weak-axis reduced beam section connection

  • Lu, Linfeng;Xu, Yinglu;Liu, Jie;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • v.27 no.3
    • /
    • pp.337-353
    • /
    • 2018
  • In previous weak-axis moment connection tests, brittle fracture always initiated near the edge of the beam flange groove weld due to force flow towards the stiffer column flanges, which is the opposite pattern as strong-axis moment connections. As part of the China NSFC (51278061) study, this paper tested two full-scale novel weak-axis reduced beam section moment connections, including one exterior frame connection specimen SJ-1 under beam end monotonic loading and one interior frame joint specimen SJ-2 under column top cyclic loading. Test results showed that these two specimens were able to satisfy the demands of FEMA-267 (1995) or ANSI/AISC 341-10 (2010) without experiencing brittle fracture. A parametric analysis using the finite element software ABAQUS was carried out to better understand the cyclic performance of the novel weak-axis reduced beam section moment connections, and the influence of the distance between skin plate and reduced beam section, a, the length of the reduced beam section, b, and the cutting depth of the reduced beam section, c, on the cyclic performance was analyzed. It was found that increasing three parametric values reasonably is beneficial to forming beam plastic hinges, and increasing the parameter a is conducive to reducing stress concentration of beam flange groove welds while increasing the parameters b and c can only reduce the peak stress of beam flange groove welds. The rules recommended by FEMA350 (2000) are suitable for designing the proposed weak-axis RBS moment connection, and a proven calculation formulation is given to determine the thickness of skin plate, the key components in the proposed weak-axis connections. Based on the experimental and numerical results, a design procedure for the proposed weak-axis RBS moment connections was developed.

Effects of loading conditions and cold joint on service life against chloride ingress

  • Yang, Keun-Hyeok;Mun, Ju-Hyun;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Computers and Concrete
    • /
    • v.22 no.3
    • /
    • pp.319-326
    • /
    • 2018
  • RC (Reinforced Concrete) members are always subjected to loading conditions and have construction joints when constructed on a big scale. Service life for RC structure exposed to chloride attack is usually estimated through chloride diffusion test in sound concrete, however the test is performed without consideration of effect of loading and joint. In the present work, chloride diffusion coefficient is measured in concrete cured for 1 year. In order to evaluate the effect of applied load, cold joint, and mineral admixtures, OPC (Ordinary Portland Cement) and 40%-replaced GGBFS (Ground Granulated Blast Furnace Slag) concrete are prepared. The diffusion test is performed under loading conditions for concrete containing cold joint. Investigating the previous test results for 91 days-cured condition and the present work, changing diffusion coefficients with applied stress are normalized considering material type and cold joint. For evaluation of service life in RC continuous beam with 2 spans, non-linear analytical model is adopted, and service life in each location is evaluated considering the effects of applied stress, cold joint, and GGBFS. From the work, varying service life is simulated under various loading conditions, and the reduced results due to cold joint and tensile zone are quantitatively evaluated. The effect of various conditions on diffusion can provide more quantitative evaluation of chloride behavior and the related service life.

A Clinical Study on the Effect of Daejo-hwan(DJH) on Climacteric Syndrome (갱년기(更年期) 증후군(症候群)에 미치는 대조환(大造丸)의 효과에 대한 임상 연구)

  • Kim, Soo-Min;Shin, Sun-Mi;Kim, Eui-Il;Lee, Jung-Eun;Yoo, Dong-Youl
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.4
    • /
    • pp.225-244
    • /
    • 2006
  • Purpose : This study was performed to assess the clinical effect of Daejo-hwan(DJH) on climacteric syndrome, not only common symptoms such as hot flushes, anxiety, palpitation and so on, but also urogenital tract disturbances like vaginal dryness and sexual problems. Methods : We randomly divided 120 women with the climacteric syndrome into two groups. One group received only DJH 2 pills(4g) a time, three times a day for 8 weeks and the other group didn't get any treatment for the same period. We evaluated sonography, DXA, blood test, female hormone test and questionnaires in the beginning as well as after 8 weeks of the treatment. Symptoms were measured by Kupperman's index, Menopausal Rating Scale and the Greene Climacteric Scale. Results : In this study, DJH was innoxious on liver and kidney. And DJH in the treated group reduced climacteric symptoms significantly as compared to the control group without enlargement of uterus myoma and the change of estradiol. In Kupperman's index and MRS, DJH in the treated group especially had effects on fatigue, shoulder pain. anxiety, headache, hot flushes as well as sexual problems. Conclusion : These results suggest that DJH can be useful in treating various climacteric symptoms including sexual problems without influences on the size of uterus myoma and estradiol.

  • PDF

Behavior of the Ground under a Building due to Adjacent Ground Excavation (근접굴착시 건물 하부 지반의 거동)

  • Lee, Jong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.4
    • /
    • pp.49-55
    • /
    • 2018
  • A pre-load of bracing was imposed to prevent the horizontal displacement on the strut of the braced wall adjacent to the building during the ground excavation. For this purpose, large scale model tests were conducted, without and with pre-load on braced wall. Adjacent building load was also imposed in different locations, that were 0 m, 1D, 2D on ground surface. In this study, model tests in 1:10 scale were performed in real construction sequences, and adjacent building was 12 m in width and the size of model test pit was 2 m in width, 6 m in height, and 4 m in length. As a result, it was found that the stability of the existing building adjacent to the braced wall within Rankine's active zone could be greatly enhanced when the horizontal displacement of the braced wall was reduced by applying a pre-load. which was larger than the designated axial force on the strut of the braced wall.