• 제목/요약/키워드: Reduced scale model test

검색결과 147건 처리시간 0.024초

1/12 축소 철근콘크리트 상부벽식-하부골조 건축물의 진동대 실험 (Shaking Table Tests of 1/12-Sale R.C. Bearing-Wall system with Bottom Piloti Frames)

  • 이한선;고동우;권기현;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.407-414
    • /
    • 2001
  • The severe shortage of the available sites in the highly developed downtown area in Korea necessitates the construction of high-rise buildings which meet the need of residence and commercial activity simultaneously. The objective of this study is to investigate the seismic performance of this type of building structures. For this purpose, two 1 :12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames have two different layouts of the plan The one is a moment-resisting frame system and the other is a moment-resisting frame system with a infilled shear wall. Then, this model was subjected to a series of earthquake excitations. The test results show that the existence of shear wall reduced the shear deformation at the piloti frame, but has almost the negligible effect on the reduction of the overturning-moment angle.

  • PDF

Extension Test of Midday Apparent Evapotranspiration toward Daily Value Using a Complete Remotely-Sensed Input

  • Han, Kyung-Soo;Kim, Young-Seup
    • 대한원격탐사학회지
    • /
    • 제19권5호
    • /
    • pp.341-349
    • /
    • 2003
  • The so-called B-method, a simplified surface energy budget, permits calculation of daily actual evapotranspiration (ET) using remotely sensed data, such as NOAA-AVHRR. Even if the use of satellite data allows estimation of the albedo and surface temperature, this model requires meteorological data measured at ground-level to obtain the other inputs. In addition, a difficulty may be occurred by the difference of temporal scales between the net radiation in daily scale and instantaneous measurement at midday of the surface and air temperatures because the data covered whole day are necessary to obtain accumulated daily net radiation. In order to solve these problems, this study attempted a modification of B-method through an extension of hourly ET value calculated using a complete instantaneous inputs. The estimation of the daily apparent ET from newly proposed system showed a root mean square error of 0.26 mm/day as compared the output obtained from the classical model. It is evident that this may offer more rapid estimation and reduced data volume.

블록식 보강토 옹벽에서의 시공단계별 보강재 타입에 따른 거동비교 (The Comparative Experiment of Geogrid Reinforcement Types with Construction Stage on Segmental Retaining Walls)

  • 이성혁;이진욱;최찬용
    • 한국지반신소재학회논문집
    • /
    • 제11권4호
    • /
    • pp.1-8
    • /
    • 2012
  • 본 논문에서는 실대형 실험을 통해 블록식 보강토옹벽에서 보강재의 타입에 따른 수평토압, 변위, 보강재의 변형률의 특성을 비교하였다. 본 연구를 통해 보강재의 타입에 따라 토압과 변위관계에서 서로 다른 거동특성을 보이고 있으며, 보강토체 내에 배치된 보강재가 연직토압 감소 및 변체변위 억제 효과 등 보강 성능이 있음을 확인할 수 있었다. 수평토압은 보강재의 특성과 변형에 따라 상단부와 하단부에서 주동토압이나 정지토압보다 크게 발생할 수 있으며, 수평토압과 벽체변위는 서로 상관성이 매우 높은 관계를 가지는 것으로 나타났다. 블록식 보강토 옹벽에서 보강재의 등고변형률선 분포는 중앙부분에서 가장 큰 변형이 발생하는 것을 확인하였다.

터널내에서 화재 발생시 연기 거동에 대한 연구 (A Study of Smoke Movement in Tunnel Fires)

  • 김상훈;김성찬;김충익;유홍선
    • 한국화재소방학회논문지
    • /
    • 제14권2호
    • /
    • pp.21-32
    • /
    • 2000
  • 본 연구는 터널에서의 화재성상을 파악하기 위해 실물 실험의 대안으로서 축소 모형 실험을 수행하였고 또한 실험결과와 비고분석하기 위하여 터널내에서의 화재에 대하여 연기거동을 수치해석하였다. 터널내에서의 연기유동은 Buoyancy force에 의해 지배되므로 Froude scaling링에 의해 얻어진 축소법칙에 따라 실물터널을 1/20로 축소한 모형에서 실험 수행하였고 검증하였다. 여기서 얻어진 결과를 수치해석 결과와 비교하였다. 수치해석은 3D 비정 렬 격자, PISO 알고리즘, 부력 Plume 모델등을 사용하였다. 분석결과 실험과 수치해석 결과가 어느정도 일침함을 확인하였고, 연층의 전달 속도, 온도 구배, 하강 높이를 확인할 수 있었다.

  • PDF

PHC-W말뚝 흙막이와 결합된 지하증설벽체 테스트베드 구축을 위한 실대형 지하증설벽체의 휨강도 및 전단강도 설정 연구 (Study on Bending and Shear Strength Setting of Full-scale Model Additional Walls for Additional Wall Test Bed Combined with PHC-W Pile Retaining Wall)

  • 우종열;유충근;김성수;최용규
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.7-17
    • /
    • 2018
  • PHC-W흙막이벽체와 결합된 지하증설벽체의 테스트베드를 구축중에 있다. 지하증설벽체의 제원을 결정하기 위하여 실대형 지하증설벽체의 핵심 부재를 제작하여 휨강도실험 및 전단강도실험을 실시하였다. 원형 PHC말뚝의 단면 형상을 개량하여 개발된 PHC-W 흙막이벽체를 건축물 지하벽체로 활용하기 위하여 합성증설벽체와 비합성증설벽체를 제작하여 휨강도 및 전단강도 실험을 수행하였다. 합성증설벽체와 비합성증설벽체에서 휨모멘트 강도 실험값 및 전단강도 실험값이 유사한 수준으로 나타났으므로 합성증설벽체 대신에 시공이 간편하고 비용이 절감될 수 있는 비합성증설벽체를 적용할 수 있다는 것을 확인하였다. 실대형 모형 증설벽체는 두께 200mm로 제작되었는데, PHC-W 흙막이벽체와 결합된 지하증설벽체의 경우 동등 지하실 규모의 통상적인 지하벽체보다 두께를 100~200mm 정도 절감할 수 있는 것을 확인할 수 있었다.

실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증 (Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test)

  • 박원일;조원범;정준화
    • 한국도로학회논문집
    • /
    • 제17권6호
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

Critical seismic incidence angle of transmission tower based on shaking table tests

  • Tian, Li;Dong, Xu;Pan, Haiyang;Gao, Guodong;Xin, Aiqiang
    • Structural Engineering and Mechanics
    • /
    • 제76권2호
    • /
    • pp.251-267
    • /
    • 2020
  • Transmission tower-line systems have come to represent one of the most important infrastructures in today's society. Recent strong earthquakes revealed that transmission tower-line systems are vulnerable to earthquake excitations, and that ground motions may arrive at such structures from any direction during an earthquake event. Considering these premises, this paper presents experimental and numerical studies on the dynamic responses of a 1000 kV ultrahigh-voltage (UHV) transmission tower-line system under different seismic incidence angles. Specifically, a 1:25 reduced-scale experimental prototype model is designed and manufactured, and a series of shaking table tests are carried out. The influence of the seismic incidence angle on the dynamic structural response is discussed based on the experimental data. Additionally, the incidence angles corresponding to the maximum peak displacement of the top of the tower relative to the ground (referred to herein as the critical seismic incidence angles) are summarized. The experimental results demonstrate that seismic incidence angle has a significant influence on the dynamic responses of transmission tower-line systems. Subsequently, an approximation method is employed to orient the critical seismic incidence angle, and a corresponding finite element (FE) analysis is carried out. The angles obtained from the approximation method are compared with those acquired from the numerical simulation and shaking table tests, and good agreement is observed. The results demonstrate that the approximation method can properly predict the critical seismic incidence angles of transmission tower-line systems. This research enriches the available experimental data and provides a simple and convenient method to assess the seismic performance of UHV transmission systems.

지속하중 및 반복하중 재하시 보강토 옹벽의 잔류변형 특성 (Time-dependent Deformation Characteristics of Geosynthetic Reinforced Modular Block Walls under Sustained/cyclic Loading)

  • 유충식;김영훈;한대희;김선빈
    • 한국지반공학회논문집
    • /
    • 제23권6호
    • /
    • pp.5-21
    • /
    • 2007
  • 보강토 옹벽은 기존 콘크리트 옹벽에 비하여 많은 장점을 지니고 있으나 장기적으로 지속하중 혹은 반복하중 등에 의한 잔류변형의 우려로 영구 구조물로서의 적극적인 적용에 장애가 되고 있다. 이 문제를 해결하기 위해서는 보강토 구조물의 시간 의존적 잔류변형 메카니즘의 규명과 아울러 잔류변형을 예측하고 제어하는 기술이 확보되어야 한다. 본 연구에서는 이러한 연구의 필요성에 근거하여 보강토 옹벽에 발생할 수 있는 장기변형 특성 고찰에 주안점을 두고 지오그리드와 표준사로 뒤채움된 모형 보강토 옹벽에 대한 지속하중 혹은 반복하중 등 다양한 하중이력에 대한 보강토 구조물의 장기변형 특성 메카니즘을 축소모형실험을 통해 고찰하였다. 그 결과 보강토 옹벽의 시간의존적 변형은 작용하는 하중특성 뿐만 아니라 뒤채움흙 및 보강재의 역학적 특성에도 많은 영향을 받는 것으로 나타났으며, 선행하중을 작용함으로써 시간 의존적 잔류변형을 제어할 수 있는 것으로 파악되었다.

근접굴착에 따른 건물 하부 통과 터널의 거동 (Behavior of Building Lower Part Passage Tunnel due to Adjacent Ground Excavation)

  • 이종민;이상덕
    • 터널과지하공간
    • /
    • 제20권5호
    • /
    • pp.369-377
    • /
    • 2010
  • 근접굴착 시 기존터널의 안정성을 확보하는 방안을 연구하였다. 흙막이벽체의 수평변위가 생기지 않도록 선행하중을 가하였다. 이를 위해 선행하중을 가하지 않은 경우와 선행하중을 가한 경우에 대해 실대형 시험을 실시하였다. 지표면에 건물하중이 없는 경우와 건물하중이 있는 경우(0 m, 1D, 2D)에 대하여 각각 실험을 실시하였다. 그 결과 선행하중을 적용시켜 흙막이벽체의 변위를 억제시켰을때 벽체배면에 있는 기존터널의 안정성이 크게 향상되는 것을 확인할 수 있었다. 본 논문에서는 흙막이벽체와 기존터널의 거동에 대하여 연구하였다. 기존터널은 지름 12 m를 사용하였으며 1:10의 축척으로 2.0 m(폭) ${\times}$ 6 m(높이) ${\times}$ 4.0 m(길이)의 크기를 가진 대형토조에서 실험을 수행하였다.

보건소 이미지 척도 개발 (Development of Public Health Center Image Scale)

  • 이인영;김은미;배상수
    • 보건행정학회지
    • /
    • 제23권4호
    • /
    • pp.415-426
    • /
    • 2013
  • Background: This study was aim to identify the specific words and to develop the scale for the public health center (PHC) image. Methods: We collected 824 words from the previous studies and by open questions and reduced them by 77 words, then which were rated properly by 355 citizens of Seoul. We examined explanatory factor analysis for 69 words, and examined content validity test and confirmatory factor analysis (CFA) for the image structures (4 factors and 16 words). And then we developed the image questionnaire using them through council. We conducted a survey and retested the PHC image scales as the measuring tool targeting 2,000 persons, and compared the inexperience and experience persons for PHC usage. Results: The image structures were consisted of 4 factors and 16 words such as 'trustworthiness' (warm, exemplary, faithful, service-mindedness, beneficial to health), 'fairness' (honesty, clear, consistent, ruled), 'development possibility' (changing, goal-directed, developmental, propulsive), and 'flexibility' (not authoritative, not perfunctory, not rigid) in total. Cronbach's ${\alpha}$ values of all factors were above 0.7. As a result of CFA, model fit indexes yielded satisfactory results (root mean square error of approximation [RMSEA] 0.049, goodness of fit index [GFI] 0.937, and adjusted goodness of fit index [AGFI] 0.912). According to the result of retest for measuring tool by using other samples, Cronbach's ${\alpha}$ values were above 0.8, and model fit indexes yielded satisfactory results (RMSEA 0.059, GFI 0.952, AGFI 0.933). RMSEAs of the inexperiences and the experiences were each 0.59, 0.68. Conclusion: A reliable, valid, and generalizable scale was created for PHC image.