• Title/Summary/Keyword: Reduced flow rate

Search Result 777, Processing Time 0.025 seconds

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

Analysis of spray cone angle of air assisted flash atomization (공기보조식 (air-assisted) 플래쉬 분무의 분무 각 확대 특성 연구)

  • Yu, Tae-U;Kim, Sae-Won;Bang, Byong-Ryeol
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • When the water jets heated up to the saturation temperature at a high line pressure are sprayed into a reduced (atmospheric) pressure through an air-assisted nozzle, the jets experience sudden exposure into a reduced pressure, get superheated and produce steam bubbles while atomization processes of jets are taking place. This process is called flash atomization. In this study the flash atomization of superheated water jets assisted by air has been studied. Sprays with flash atomization have been photographed at various water and air flow rates and water superheats. It has been found that the spray angle with flash atomization increases with water superheat and water flow rate but decreases with air flow rate. The degree of change of spray angle has been analyzed and correlated as a function of superheat, air and water flow rates.

  • PDF

The Effects of Forming Depth and Feed Rate on Forming Force of Flow Forming (유동성형의 성형력에 미치는 가공깊이와 이송속도의 영향)

  • Nam K. O.;Yeom S. H.;Kang S. J.;Hong S. I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.251-254
    • /
    • 2005
  • The flow forming has been used to produce long thin walled tube parts, with reduced forming load and enhanced mechanical and surface quality for a good finished part compared with other method formed parts. So flow forming technique is used widely in industrial production. Especially spinning and flow farming techniques an used frequently in automotive, aerial, defense industry. In this paper, FEM analysis of three-roller backward flow forming of a workpiece is carried out to study effects of forming depth and feed rate on forming force. The axial and radial forces on several forming depth and feed rate conditions are obtained. The phenomena such as bell mouth, build up and bulging during simulation are observed as well.

  • PDF

Growth Responses of the Filter-Feeding Clam Gafrarium tumidum to Water Flow: A Field Manipulation Experiment

  • Cheung, S.G.;Shin, Paul K.S.
    • Journal of Ecology and Environment
    • /
    • v.30 no.2
    • /
    • pp.109-119
    • /
    • 2007
  • The effect of water flow on the growth of Gafrarium tumidum was studied in the field using open cages constructed with stainless steel net and perspex in which holes were drilled. Cages with different flows (25, 50 and 75% of the control) were made by varying the area of perspex being drilled. Reduction in flow rate was directly proportional to the undrilled area, and the mean flow rate of the different treatment groups varied from 3.12 cm/s for the 25% exposure to 12.48 cm/s for the control cages. At the end of the 3-month experiment, no significant differences in sediment characteristics were found among the treatments. Growth in shell length, shell weight and tissue dry weight was, however, positively correlated with flow rate. Percentage increases ranged from $3.0{\sim}8.3%$ for shell length, $9.9{\sim}23.1%$ for shell weight and $17.2{\sim}53.3%$ for tissue dry weight. Condition index of the clam was not significantly different among the treatments. Seston depletion effect could reduce growth in G. tumidum only when water flow was reduced to 25% of the control. G. tumidum also exhibited different responses in shell and tissue growth at low flow rates, in which shell growth continued to decrease as flow rate decreased whereas tissue growth was relatively independent of low flows at 25 and 50% of the control. It was suggested that when seston flux was reduced at slow flows, it would be a better strategy for G. tumidum to channel energy for gonad development instead of shell growth during the reproductive stage.

A Study on the Effects of Filling and Packing Phases on Injection Molding Process (충전과 보압과정이 사출성형공정에 미치는 영향에 관한 연구)

  • 김현필;김용조
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.4
    • /
    • pp.44-53
    • /
    • 2002
  • Injection molding process factors such as molding temperature, injection pressure, flow rate and flow velocity, must be controlled properly in filling and packing phases in the injection molding process. In this study, effects of these factors on the injection molding were investigated through the flow analysis for the filling and packing phases. Molding troubles like flow mark weld line, sink ma가 short shot and warpage car be caused by these injection molding process factors. Among them the short shot was caused by the fact that the packing pressure could not reach properly to the filling end part in the packing phase and hence the flow rate could not be supplied to the full. In addition as the flow rate for the volumetric shrinkage during the f개zen phase could not be supplied Properly by the packing pressure, the short shot appeared. Here, the volumetric shrinkage reduced with increasing the packing pressure and also the warpage of molded part increased with increasing the packing Pressure.

A Study on the Lubrication Flow Distribution in a Six-speed Automatic Transmission Valve Body (6속 자동변속기 밸브바디의 윤활오일유량 분배 특성 연구)

  • Kim, Jin-Yong;Na, Byung-Chul;Lee, Kye-Cheul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • In general, a valve body of the automatic transmission(AT) is controlled by the clutch, the brake and lubricating oil flow in a hydraulic system and lubricant flow for each valve can be adjusted independently. To increase the lifetime of AT, the lubrication flow rate in a valve body for a 6 speed AT based parallel hybrid electric vehicle must be provided with proper oil distribution and control. In this study, we carried out several experiments without the inner parts of AT and with a AT assembly. The variation of the flow rate on oil temperature and pressure between an oil supply port and the outlets of the lubrication port was evaluated and analyzed. In the case of AT without the inner parts, it was evident that as the oil required for an operation of the clutch and brake was discharged from the outlet port, the flow rate from each lubrication port is decreased. However, the flow rate of the AT assembly was slightly increased. In addition, the lubrication flow rate was increased with increasing the oil temperature, and also it was reduced with increasing the oil pressure. Details of the resulting data are discussed.

Development of PZT Piezoelectric Biosensor for the Detection of Formaldehyde (Formaldehyde 측정을 위한 PZT 압전 바이오센서 개발)

  • 김병옥;곽성곤;임동준
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.477-482
    • /
    • 1998
  • A biosensor with PZT piezoelectric ceramic crystal was developed for the detection of formaldehyde gas. Poled PZT piezoelectric ceramic disk was made from ZrO2, TiO2 and Nb2O5, together with the addition of PbO and polyvinyl alcohol, through various processes of mixing, calcination drying, crushing, forming, sintering, polishing, ion coating and poling. Oscillator circuit of sensor was made of operational amplifier(AD811AN). Formaldehyde dehydrogenase was immobilized onto a piezoelectic ceramic crystal, together with the cofactors, reduced glutathione and nicotinamide adenine dinucleotide. The effect of flow rate on the sensitivity was determined by varing the flow rate of carrier gas from 24.7mL/min to 111.7mL/min through detector cell. The results indicated that as the flow rate was increased, the recovery rate was increased. And a significant increase in the sensitivity was observed in enhanced flow rate of carrier gas. Frequency difference(ΔF) of immobilized PZT piezoelectic disk increased proportionally to the concentration gas and reproduced to repeated exposures of formaldehyde gas(28ppm, Δ68Hz).

  • PDF

A Study on the Effects of Filling and Packing Phases on the Injection Modeling (사출성형에 대한 충전과 보압과정의 영향에 관한 연구)

  • 김현필;김용조
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.112-118
    • /
    • 2002
  • Injection molding process factors such as molding temperature, injection pressure, flow rate and flow velocity, must be controlled properly in filling and packing phases in the injection molding process. In this study, effects of these factors on the injection molding were investigated through the flow analysis fur the filling and packing phases. Molding troubles like flow mark, weld line, sink mark, short shot and warpage can be caused by these injection molding process factors. Among them, the short shot was caused by that the packing pressure could not reach properly to the filling end part in the packing phase and hence the flow rate could not be supplied to the full. In addition, as the flow rate for the volumetric shrinkage during the frozen phase could not be supplied properly by the packing pressure, the short shot appeared. Here, the volumetric shrinkage reduced with increasing the packing pressure and also the warpage of molded part increased with increasing the packing pressure.

  • PDF

UNDERSTANDING OF NAVIER-STOKES EQUATIONS VIA A MODEL FOR BLOOD FLOW

  • Choi, Joon-Hyuck;Kang, Nam-Lyong;Choi, Sang-Don
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.11 no.1
    • /
    • pp.31-39
    • /
    • 2007
  • A pedagogic model for blood flow is introduced to help medicine majors understand a simplified version of Navier-Stokes equations which is known to be a good tool for interpreting the phenomena in blood flow. The pressure gradient consists of a time-independent part known as Hagen-Poiseuille's gradient and a time-dependent part known as Sexl's, and the model formula for the volume rate of blood flow is reduced to a very simple form. For demonstration, the blood rate in human aorta system is analyzed in connection with the time-dependence of pressure gradient. It is shown for Sexl's part that the flow rate lags the pressure gradient by ${\pi}/2$, which is thought to be due to the relaxation process involved.

  • PDF

The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System

  • DEDE SAGSOZ, Yesim;YILMAZ, Alper Erdem;EKMEKYAPAR TORUN, Fatma;KOCADAGISTAN, Beyhan;KUL, Sinan
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.261-268
    • /
    • 2022
  • In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 μS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.