• Title/Summary/Keyword: Recur

Search Result 279, Processing Time 0.047 seconds

Study on the Integration Stability and the Accuracy of Some Friction Models for the Dynamic Analysis Using Recurdyn (RecurDyn을 이용한 동적 해석 시 마찰모델에 따른 적분 안정성 및 정확성 연구)

  • Yoo, Hong-Hee;Lee, Jun-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.11
    • /
    • pp.1111-1117
    • /
    • 2008
  • During the dynamic analysis of a system, the Coulomb friction law is emploved to calculate the friction force. Since the static friction coefficient is only employed during the zero relative velocity, it is impractical to employ the coefficient during the dynamic analysis. To calculate the static friction force, therefore, some friction models have been developed. In this study, the integration stability and the accuracy of the models are investigated with some numerical examples. The effect of time step size during the numerical integration is also investigated. The numerical study shows that the friction model employed for most commercial codes is not as good as the one proposed in this study.

Application of superficial keratectomy and soft contact lens for the treatment of symblepharon in a cat: a case report

  • Kim, Youngsam;Kang, Seonmi;Seo, Kangmoon
    • Journal of Veterinary Science
    • /
    • v.22 no.2
    • /
    • pp.19.1-19.5
    • /
    • 2021
  • A 7-month-old intact female Persian cat was diagnosed with symblepharon accompanied by epiphora, brownish ocular discharge, and ocular discomfort in the left eye. Superficial keratectomy (SK) was performed to remove adhesions between the conjunctiva and cornea. To prevent re-adhesion after SK, the detached conjunctival tissue was sutured to the corneal limbus, and a soft contact lens (SCL) was inserted and a partial temporary tarsorrhaphy was performed. The SCL and tarsorrhaphy sutures were maintained for 22 days, and symblepharon did not recur 347 days postoperatively. SK combined with SCL is a relatively easy and cost-effective surgical option for feline symblepharon.

Mesotherapy with Snake Venom Pharmacopuncture to Treat Hand Eczema: Two Cases Report

  • Kim, Sungha;Lee, Jinbok;Shin, Minseop
    • Journal of Pharmacopuncture
    • /
    • v.23 no.4
    • /
    • pp.273-276
    • /
    • 2020
  • Hand eczema is a recurrent and resistant disease that seriously affects the quality of life of patients; currently, there are no ideal treatments for hand eczema. Here, we describe two patients who presented with hand eczema to illustrate the potential efficacy of mesotherapy with snake venom pharmacopuncture (SVP). A 23-year-old woman (Case 1) and a 47-year-old woman (Case 2) presented to the clinic with symptoms of pruritic rash, blisters, and itchiness on both the hands and the left hand, respectively. Both patients were diagnosed with hand eczema based on the physical examination of blisters and redness only on the hands. The patients underwent 1 month (Case 1) and 1 week (Case 2) of mesotherapy with SVP. After treatment, the lesions completely improved and did not recur at 1 year of follow-up. These outcomes suggest that mesotherapy with SVP may be effective for the resolution of hand eczema; however, further research is needed to confirm these findings.

Endpoint Depth When Removing Xanthelasma Using CO2 Laser Ablation: A Case Report

  • Park, Jeong Do;Kim, Se Young;Jeong, Hyun Gyo;Wee, Syeo Young
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.246-249
    • /
    • 2021
  • The carbon dioxide (CO2) laser is one of the treatment options used for xanthelasma palpebrarum. However, even if the full dermal layer is removed, the lesion can recur due to the residual lipid deposits. A 44-year-old male patient with xanthelasma on both upper eyelids was treated with a pulsed dye CO2 laser. On the right upper eyelid, we carried out a CO2 laser treatment until the yellowish plaque was almost invisible and the full thickness of the dermal layer was removed. On the left upper eyelid, the dermal layer was partially removed and an additional squeezing out of yellowish particles was done. The lesion treated by the squeezing out of lipid droplets showed better long-term results than the lesion treated up to the deeper dermal layer.

Chemical Pleurodesis Using a Viscum album Extract in an Infant with Postoperative Chylothorax: A Case Report

  • Yun, Taeyoung;Kwon, Hye Won;Park, Samina;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.91-94
    • /
    • 2022
  • Chylothorax after thoracic surgery is a rare complication, and treatment for refractory chylothorax is challenging. We report a case of chylothorax after cardiothoracic surgery in an infant after failure of conservative management and thoracic duct ligation. The patient underwent chemical pleurodesis with a Viscum album extract. The treatment was successful and chylothorax did not recur.

Peripheral Vertigo and Tinnitus: Case Report, Aeromedical Assessment of Therapy (말초성 어지럼 및 이명: 증례보고 및 항공의학적 고찰)

  • Kim, Young Hyo
    • Korean journal of aerospace and environmental medicine
    • /
    • v.31 no.2
    • /
    • pp.51-53
    • /
    • 2021
  • Aviation medical examiners should always keep two principles in mind when evaluating patients with vertigo: Does this disease render him or her incapacitated? And does this disease recur? Meniere's disease accompanies vertigo and hearing symptoms such as hearing loss and tinnitus and is particularly important because it can render the patient incapacitated and has recurrent consequences. In this case, we intended to investigate the course of a patient who was evaluated with symptoms of dizziness and tinnitus and to review the patient's judgment result according to the principles of aeromedical evaluation.

One Case Report of Panic Disorder Patient Improved by Korean Medicine Treatment Alone (공황장애 한의 단독 치료 치험 1례)

  • Ji You Beag;Sang Chul Jang;Jae Ryong Bae
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.22 no.1
    • /
    • pp.83-96
    • /
    • 2023
  • Objective : The purpose of this study is to report that patients with panic disorder were able to discontinue the psychotropic medication through Korean Medicine treatment alone. Methods : The patient diagnosed with panic disorder were hospitalized on the 9th and were treated steadily through outpatient treatment afterwards with herbal medicine, acupuncture, cupping therapy, and Whidam's Sugi therapy while taking the chemical. Treatment effects were evaluated through BAI, BDI, STAI-X-1, CSEI-s, GIS, NDI-K, and EQ-5D measurements. Results & Conclusions : The patient's anxiety was relieved and the psychotropic medication was discontinued, but it did not recur. And after inpatient treatment, he has been steadily receiving outpatient treatment on a regular basis, maintaining an improved state and leading a normal daily life.

Immunohistochemical Characteristics of Primary and Recurrent Pleomorphic Adenoma (원발성 다형선종과 재발성 다형선종의 면역조직화학적 특성)

  • Suh Myung-Whan;Hah J.Hun;Lee Kyung-Bun;Jung Young-Ho;Kwon Seong-Keun;Kim Kwang-Hyun;Sung Myung-Whun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.21 no.2
    • /
    • pp.146-150
    • /
    • 2005
  • Background and Objectives: When the pleomorphic adenoma(PA) recures, the tumor tends to become a multinodular mass that infiltrates into the normal tissue which is not a common condition for a benign tumor. This manifestation is probably due to the difference in cell biology of the recurrent tumor compared to that of the primary PA. The aim of this study is to assay the immunhistochemical characteristics of the recurrent PA compared to the primary PA and to evaluate whether this property can be used for developing a method that can select the patients who have higher risk to recur. Materials and Methods: Thirteen patients were enrolled in the primary PA group and 15 patients who had a recurrent PA were enrolled in the recurrent PA group. To evaluate the cell biology of the tumor, immunohistochemical stainings of Ki-67, bcl-2 and p53 were performed. Results: There was no difference in the expression of Ki-67 (p=0.117, p=.208) and p53 (p=.430, p=.328). The extent stained by bcl-2 was significantly larger in the recurrent PA group (p=.033, p=.014). The expression of bcl-2 did not increase while time passed. Conclusion: The high expression of bcl-2 seems to be a property of the recurrent PA group which can be found even during first operation before recurrence. By this immunhistochemical characteristic, we would be able to sort out the patients who have higher risk to recur.

Comparative Study of Finite Element Analysis for Stresses Occurring in Various Models of the Spent Nuclear Fuel Disposal Canister due to the Accidental Drop and Impact on to the Ground (추락낙하 사고 시 지면과의 충돌충격에 의하여 다양한 고준위폐기물 처분용기모델에 발생하는 응력에 대한 유한요소해석 비교연구)

  • Kwon, Young-Joo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.5
    • /
    • pp.415-425
    • /
    • 2017
  • Stresses occur in the spent nuclear fuel disposal canister due to the impulsive forces incurred in the accidental drop and impact event from the transportation vehicle onto the ground during deposition in the repository. In this paper, the comparative study of finite element analysis for stresses occurring in various models of the spent nuclear fuel disposal canister due to these impulsive forces is presented as one of design processes for the structural integrity of the canister. The main content of the study is about the design of the structurally safe canister through this comparative study. The impulsive forces applied to the canister subjected to the accidental drop and impact event from the transportation vehicle onto the ground in the repository are obtained using the commercial rigid body dynamic analysis computer code, RecurDyn. Stresses and deformations occurring due to these impulsive forces are obtained using the commercial finite element analysis computer code, NISA. The study for the structurally safe canister is carried out thru comparing and reviewing these values. The study results show that stresses become larger as the wall encompassing the spent nuclear fuel bundles inside the canister becomes thicker or as the diameter of the canister becomes larger. However, the impulsive force applied to the canister also becomes larger as the canister diameter becomes larger. Nonetheless, the deformation value per unit impulsive force decreases as the canister diameter increases. Therefore, conclusively the canister is structurally safe as the diameter increases.

Running stability analysis of the Semi-Crawler Type Mini-Forwarder by Using a Dynamic Analysis Program (동역학분석 프로그램을 이용한 반궤도식 임내작업차의 주행안정성 분석)

  • Kim, Jae-Hwan;Park, Sang-Jun
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.1
    • /
    • pp.98-103
    • /
    • 2015
  • This study was conducted to analyze the running stability of a semi-crawler type mini-forwarder. The running stability analysis was performed by using a dynamic analysis program, RecurDyn. Physical properties of the semi-crawler type mini-forwarder was performed by using 3D CAD modeler, AutoCAD 3D. As a result from the computer simulation of stationary sideways overturning, it was found that the semi-crawler type mini-forwarder runs safely on a road with a slope not bigger than $20^{\circ}$ regardless whether it is empty or loaded, but in case of a road with a slope bigger than $20^{\circ}$, it is assumed that it is difficult for the car to run safely due to some dangers. In addition, it was found that the critical slope of its sideways overturning gets much smaller when empty since the location of its gravity center is elevated and much higher when it is loaded. As a result from the computer simulation of its hill-climbing ability, since the running speed is unstable in case of a road with a vertical slope not smaller than $28^{\circ}$, it is assumed that it is safe to drive it on a road with a slope not bigger than $28^{\circ}$. Taking a look at the result from an analysis of the running safety when it passes an obstacle, it was observed that a front tire comes off the ground when the running speed of the car is 5 and 4 km per hour respectively when it is empty and loaded while the gravity center of the front tire is watched. When taking a look at the changes in the location of the gravity center of the rear wheel crawler shaft, it was not found that the shaft comes off the ground at the test speeds both when it is empty and loaded.