• 제목/요약/키워드: Rectangular Partition

검색결과 20건 처리시간 0.023초

유한열전도율(有限熱傳導率)의 격판(隔板)을 갖는 수직구형(垂直矩形) 밀폐공간(密閉空間)에서의 자연대류(自然對流)에 관(關)한 수치적(數値的) 연구(硏究) (A Computational Study of Natural Convection in Vertical Rectangular Enclosures with Partiton Plates of Finite Thermal Conductivity)

  • 박만흥;이재헌
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 1982
  • A theoretical study by numerical method has been performed on the natural convection of an air contained in enclosures. The enclosures have rectangular cross section with one vertical wall heated and the other cooled, and with two horizontal partition plates of finite thermal conductivity. Steady two-dimensional flow was assumed. The computation was executed by means of the Implicit Alternating Direction (I.A.D) finite-difference method. Two partition plates of Aluminium whose thickness were 0.05mm was employed in computation. Isothemals, streamlines, local Nusselt numbers and mean Nusselt numbers were obtained for various Grashof numbers and aspect ratio and these results were compared with those in the case of the enclosure with two horizontal insulated plates. From the present results, the heat transfer in the case of partition plates was greater than that in the case of insulation. This study suggests a method to measure the overall heat-transfer of coefficient in double walls which supported by partition plates for insulative construction.

  • PDF

4각 순환유동층의 수력학적 특성 (Hydrodynamic Characteristics of the Rectangular Type Circulating Fluidized Bed)

  • 현상열;이관석
    • 열처리공학회지
    • /
    • 제10권4호
    • /
    • pp.232-236
    • /
    • 1997
  • A rectangular type circulating fluidized bed (CFB) with an internal nozzle and two partition walls was proposed. In this modified CFB, an internal nozzle and two slanted partition walls were additionally set in the riser. This cold mode apparatus was made of acrylic resin; the riser was 1500mm high and $1000{\times}1000mm^2$ in the cross sectional area, the internal nozzle was 200mm high and 10mm in the inner diameter, and the partition wall was 7mm thick. Glass beads of $91{\mu}m$ in the mean diameter were employed as bed materials. In the cold mode by using the proposed CFB with an internal nozzle, it was possible to change the particle hold up by changing the gas flow ratio of the nozzle to the total(Qn/Qt). It was found that the inflection point which devided the bed structure between the dense and the dilute phase in the riser varied with Qn/Qt.

  • PDF

EFFECT OF PARTITION AND SPECIES DIFFUSIVITY ON DOUBLE DIFFUSIVE CONVECTION OF WATER NEAR DENSITY MAXIMUM

  • Sivasankaran, S.;Kandaswamy, P.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제11권1호
    • /
    • pp.71-83
    • /
    • 2007
  • The double diffusive convection of cold water in the vicinity of its density maximum in a rectangular partitioned enclosure of aspect ratio 5 with isothermal side walls and insulated top and bottom is studied numerically. A thin partition is attached to the hot wall. The species diffusivity of the fluid is assumed to vary linearly with concentration. The governing equations are solved by finite difference scheme. The effects of position and height of the partition, variable species diffusivity and enclosure width are analyzed for various hot wall temperatures. It has been found that adding partition on the hot wall reduces the heat transfer. The density inversion of the water has a great influence on the natural convection. When increasing species diffusivity parameter heat and mass transfer rate is decreased.

  • PDF

가변 격판을 갖는 사각공간 내의 혼합대류에 대한 실험과 수치해석 (An Experiment and Numerical Analysis of Mixed Convection in a Rectangular Space with Variable Partition)

  • 이광성;신재호;이중섭;정한식;정효민
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1230-1235
    • /
    • 2001
  • The laminar convection heat transfer in a ventilated space with various horizontal partitions was studied numerically and experimentally. The experimental results by holographic interferometer showed good agreements with the numerical results. For the numerical study, the governing equations were solved by using a finite volume method for $46.6\leqRe\leq1332,\;1460\leqGr\leql1585$, Pr=0.71 and the variations of partition lengths. The isotherms and velocity vectors have been represented for various parameters. As the length of partition increases, the convection heat transfer decreases. Based on the numerical data, a correlation was obtained for the dimensionless mean Nusselt number in terms of $Gr/Re^2$. In the region of $Gr/Re^2$<1, the mean Nusselt number was very small, but in the region of $Gr/Re^2\geq1$, the mean Nusselt number was constant.

  • PDF

카테시안 곱의 역 맥락에서 살펴본 분수 나눗셈 알고리즘의 시각적 통합모델에 대한 연구 (A study on the visual integrated model of the fractional division algorithm in the context of the inverse of a Cartesian product)

  • 이광호;박중규
    • 한국수학교육학회지시리즈C:초등수학교육
    • /
    • 제27권1호
    • /
    • pp.91-110
    • /
    • 2024
  • 본 연구의 목적은 이 통합모델인 직사각형 분할 모델을 초등학교 교실에서 교수·학습하였을 때, 학생들이 이 통합모델을 어떻게 이해하는지, 분수 나눗셈 상황들 사이의 관계를 어떻게 구성하는지 알아보는 데 있다. 이 연구를 통해 얻은 결론은 다음과 같다. 첫째, 제수의 역수를 곱하는 이유나 역수의 의미를 상기시키기 위해서 분수의 나눗셈식을 측정 맥락이나 단위 비율 결정 맥락으로 해석하여 계산 과정을 설명할 필요가 있다. 둘째, 직사각형 분할 모델은 분수의 나눗셈식을 측정 맥락으로 해석할 때 기존 모델에서 나타나는 우회적이거나 부적절한 부분을 보완할 수 있다. 또한 카테시안 곱의 역 맥락의 문제에서 표준알고리즘을 도출하기에 적절한 모델이라고 할 수 있다. 셋째, 카테시안 곱의 역 맥락에서 직사각형 분할 모델은 측정 맥락과 단위 비율 결정 맥락에서의 계산 과정을 자연스럽게 드러낼 수 있다. 그리고 하나의 나눗셈식이 왜 두 가지 해석이 가능한지를 보여줄 수 있어 통합모델로 사용할 수 있다.

HV 분할 방식을 이용한 fractal 영상 압축에 관한 연구 (A study of Fractal Image Compression with HV partition)

  • 이문직;정진현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2240-2242
    • /
    • 1998
  • Image coding based on fractal theory presents highly compressed image. In this paper, we discuss about compression of Image using HV partition method. HV partition scheme devides the image adaptively in horizontal and vertical axis. And for reducing the enconding time for the domain-range comparison, we use classification scheme, which uses the order of brightness of the rectangular portion of the image. This paper focused on the technique to reduce coding time which is a problem in traditional fractal compression by adaptive selection of image and its classification method.

  • PDF

구역분할 알고리즘을 이용한 다수 탐색플랫폼의 구역할당 방법 (A Methodology for Partitioning a Search Area to Allocate Multiple Platforms)

  • 안우선;조윤철;이찬선
    • 한국군사과학기술학회지
    • /
    • 제21권2호
    • /
    • pp.225-234
    • /
    • 2018
  • In this paper, we consider a problem of partitioning a search area into smaller rectangular regions, so that multiple platforms can conduct search operations independently without requiring unnecessary coordination among themselves. The search area consists of cells where each cell has some prior information regarding the probability of target existence. The detection probability in particular cell is evaluated by multiplying the observation probability of the platform and the target existence probability in that cell. The total detection probability within the search area is defined as the cumulative detection probability for each cell. However, since this search area partitioning problem is NP-Hard, we decompose the problem into three sequential phases to solve this computationally intractable problem. Additionally, we discuss a special case of this problem, which can provide an optimal analytic solution. We also examine the performance of the proposed approach by comparing our results with the optimal analytic solution.

FVM과 반무한체 해석을 이용한 표면온도예측에 관한 연구 (A Study for Estimation of the Surface Temperature Rise Using the FVM and Semi-Infinite Solid Analysis)

  • 김태완;이상돈;조용주
    • Tribology and Lubricants
    • /
    • 제18권6호
    • /
    • pp.389-395
    • /
    • 2002
  • The surface temperature at the interface of bodies in a sliding contact is one of the most important factors influencing the behavior of machine components. The calculation of the surface temperature at a sliding contact interface has been an interesting and important subject for tribologist. Temperature analyses were usually performed under the consideration contacted two bodies as semi-infinite. But the analysis was difficulty in being applied to finite body and considering the boundary condition. In this study, contact temperature rise of two finite bodies and surfaces due to frictional heating under the rectangular and the circular sliding contact is calculated. Heat partition factor is calculated using semi-infinite solid analysis and the temperature of the finite bodies is calculated using FVM. It will be shown that Most frictional heat in the fore part of contact region for sliding direction is conducted into body that has a moving heat source and the site of the maximum temperature rise moves to the opposite direction of sliding during sliding.

동축-원추-방사형 선로변환에 의한 마이크로파 전력분할/합성기의 광대역 설계 (Design of a Broadband Microwave Power Divider/Combiner using Coaxial-Conical-Radial Transmission Line Conversion)

  • 최영규
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1385-1390
    • /
    • 2011
  • A coaxial-conical-radial transmission line conversion circuits have been investigated to realize a low loss high performance microwave power divider/combiner. In order to optimize the characteristics of the device, the power divider/combiner was designed separately with two parts-the inner part and the outer part. Utilizing the rectangular approximation of the outer part, we can design the low loss device which is not affected by the partition number N of the outer part. The small return loss which is lower than 20dB was obtained on the frequency range of 5.15GHz(7.45~12.60GHz). A conical connector was employed for smooth connection between the central coaxial line and the outer radial line. Making use of the $47^{\circ}$ and $90^{\circ}$ 2-stage conical connector, the return loss lower than 30dB was obtained on the operating frequency range of 5GHz. The total return loss of the designed divider/combiner was lower than 20dB on the frequency range of 5GHz for the partition number N=11, N=12 and N=16.

Rotationally Invariant Space-Time Trellis Codes with 4-D Rectangular Constellations for High Data Rate Wireless Communications

  • Sterian, Corneliu Eugen D.;Wang, Cheng-Xiang;Johnsen, Ragnar;Patzold, Matthias
    • Journal of Communications and Networks
    • /
    • 제6권3호
    • /
    • pp.258-268
    • /
    • 2004
  • We demonstrate rotationally invariant space-time (ST) trellis codes with a 4-D rectangular signal constellation for data transmission over fading channels using two transmit antennas. The rotational invariance is a good property to have that may alleviate the task of the carrier phase tracking circuit in the receiver. The transmitted data stream is segmented into eight bit blocks and quadrature amplitude modulated using a 256 point 4-D signal constellation whose 2-D constituent constellation is a 16 point square constellation doubly partitioned. The 4-D signal constellation is simply the Cartesian product of the 2-D signal constellation with it-self and has 32 subsets. The partition is performed on one side into four subsets A, B, C, and D with increased minimum-squared Euclidian distance, and on the other side into four rings, where each ring includes four points of equal energy. We propose both linear and nonlinear ST trellis codes and perform simulations using an appropriate multiple-input multiple-output (MIMO) channel model. The 4-D ST codes constructed here demonstrate about the same frame error rate (FER) performance as their 2-D counterparts, having however the added value of rotational invariance.