• Title/Summary/Keyword: Rectal

Search Result 1,130, Processing Time 0.03 seconds

Reirradiation in Rcurrent Cervical Cancer Following Definite Radiation Therapy (근치적 방사선치료 후 재발한 자궁경부암의 재 방사선치료)

  • Kim, Jin-Hee;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.230-236
    • /
    • 2001
  • Purpose : To evaluate treatment results in terms of local control, complications and survival after reirraidiation in recurrent cervical cancer following definite radiation therapy. Material and methods : From November 1987 through March 1998, eighteen patients with recurrent cervical cancer following definite radiation therapy were subsequently treated with reirradiation at Keimyung University Dongsan Medical Center. In regard to the initial FIGO stage, one patient was stage la, five were stage IIa, three were IIb, two were IIb and two were IVa. The age range was 37 to 79 years old with median age of 57. The time interval from initial definite radiation therapy to recurrence ranged from 6 to 122 months with a median of 58 months. The recurrent sites were the uterine cervix in seven patients, vagina in ten and pelvic lymph node in one. Reirradiation was peformed with external radiation and intracavitary radiation in twelve patients, external radiation and implantation in four and external radiation alone in two. The range of external radiation dose was $2,100\~5,400\;cGy$ and the range of the total radiation dose was $3,780\~8,550\;cGy$. The follow-up periods ranged from 8 to 20 months with median of 25 following reirradiation. Results : Fourteen of eighteen patients $(78\%)$ had local control just after reirradiation. The two year disease free survival (2YDFS) rate was $53.6\%$. There were statistically significant differences in the 2YDFS according to both recurrent site (2YDFS $28.5\%$ in uterine cervix, $71.4\%$ in vagina, (p=0.03)) and the total dose (2YDFS $71.8\%$ in >6,000 cGy , $25\%$ in $\leq6,000$ cGy, p=0.007). Seven of ten patients who were followed for more than 20 months remain alive and disease free (7/18, $39\%$). Patients treated with external radiation and intracavitary radiation had a higher rate of 2YDFS. Seven patients including 4 patients with no local control experienced local failure in the uterus or vagina and two patients died with distant metastasis. Complications included rectal bleeding in 3 patients, bowel obstruction treated with surgery in two, hematuria in one, radiation cystitis in two, soft tissue swelling in two and vaginal necrosis spontaneously healed in one. There was no statistical difference in complications according to the total dose or the time to recurrence from initial radiation. Conclusion : In patients with recurrence following definite radiation therapy in the uterine cervical cancer, reirradiation may be effective but requires an effort to reduce radiation induced severe complications.

  • PDF

Predictors of Meningitis in Febrile Infants Aged 3 Months or Younger (열이 있는 3개월 이하의 영아에서 수막염의 예측에 대한 연구)

  • Song, Hyang Soon;Kim, Eun Ok;Jang, Young Taek
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose : The purpose of this study was to identify useful predictors for diagnosing bacterial meningitis and performing CSF studies in febrile infants three months or younger. Methods : Six hundred and fifty two febrile infants with a rectal temperature ${\geq}38.0^{\circ}C$ presented from January 2003 to April 2008 and were retrospectively studied. The total white blood cell count (WBC), band count, absolute neutrophil count (ANC), quantitative C-reactive protein (CRP) and blood cultures were performed on admission. The clinical variables associated with bacterial meningitis were analyzed. Results : In patients with bacterial meningitis, the clinical variables including CRP (P=0.036), band count (P=0.037), ANC (P=0.036) and age (P=0.001) were significantly different. The area under the receiver-operating characteristic curve was 0.969 for CRP, 0.946 for the band count, 0.765 for the ANC and 0.235 for age. A CRP cutoff point of 8 mg/dL was determined to maximize both the sensitivity and specificity (sensitivity 83%, specificity 95%, likelihood ratio 16.6). A CRP concentration of <7 mg/dL "ruled-out" bacterial meningitis, with a likelihood ratio of 0.17, a posttest probability of <0.1% and negative predictive value 91%. A CRP concentration greater than 9 mg/dL had a much higher likelihood ratio (20.1) than the band count (16.6) and ANC (2.2). Conclusion : The CRP concentration was a useful laboratory test for the differential diagnosis of bacterial meningitis among febrile infants three months of age or younger. A CRP concentration of <7 mg/dL effectively ruled out bacterial meningitis; a value ${\geq}9mg/dL$ increased the clinical suspicion of bacterial meningitis and the need for CSF evaluation.

  • PDF

Effects of Sprinkler and Fan Cooling System in Loose Barn on the Physiological Parameter and Milk Productivity in Holstein Cows During Summer (개방식우사내 Fan과 Sprinkler설치가 착유우의 생리적 변화 및 유생산성에 미치는 영향)

  • 정태영;이현민;김종민;김동일;이연섭;이인형
    • Journal of Animal Environmental Science
    • /
    • v.2 no.1
    • /
    • pp.41-52
    • /
    • 1996
  • This experiment was carried out to study the effect of sprinkler and fan cooling system on the physiological parameter, milk production and milk composition for Holstein cows in hot, humid climates. Thirty cows were assigned to one of two sections of open-sided loose barn. Water nozzles of sprinkler system were spaced in line at 1.2m intervals. Forced air was provided by 85cm diameter fans at rate of 3.4㎥/sec. The results obtained from these experiments are as follows: 1. There was no significant difference in meteorological data between control and fan + sprinkler cooling system(treatment group). 2. Skin temperature and rectal temperature of the treatment group were significantly lower than those of the control group (32.96 : 39.53$^{\circ}C$ vs 34.02 : 41.21$^{\circ}C$ respectively) (P<0.05). 3. Serum cortisol concentration of the treatment group(0.90$\mu\textrm{g}$/dL) was lower than that of control group(1.44$\mu\textrm{g}$/dL)(P<0.05). 4. Milk production of cows cooled with a sprinkler and fan cooling system was significantly higher than that of no cooling system (P<0.0l). 5. Lactose, protein and solid-not-fat content of milk were not changed by the treatments. Milk fat content of the control(3.23%) was low compared with the treatment group(3.38%). Somatic cell count was reduced by 26.63% in the treatment. The results indicate that a sprinkler and fan cooling systems can provide an effective means to relieve heat stress and enhance productivity of lactating Holstein cows during hot and humid summer season.

  • PDF

The Effect of Feeding Concentrates Frequency on Weight Change and Colic of Jeju Cross-bred Horses (농후사료 급여 횟수가 제주산마(제주마×더러브렛)의 체중과 산통에 미치는 영향)

  • Woo, Jae-Hoon;Son, Jun-Kyu;Yang, Byung-Chul;Kim, Nam-Young;Shin, Sang-Min;Shin, Moon-Cheol;Yoo, Ji-Hyun;Park, Nam Geon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.38 no.4
    • /
    • pp.224-230
    • /
    • 2018
  • This study was conducted to investigate the effects of concentrate feeding frequency on weight change and the colic of Jeju cross-bred horses. Around thirty-six old Jeju cross-bred horses were divided into three groups and were investigated by feeding the concentrate feed at 2.5% of their body weight 2 times, 3 times, or 4 times daily. Although the total weight gain and daily weight gain for the different feeding frequencies were higher with feeding concentrates 4 times daily compared with the other treatment groups, there was no statistically significant difference between the groups (p>0.05). Rectal temperatures were above the normal range in weeks 11 to 12, but there was no statistically significant difference between the groups (p>0.05). Fecal pH was below the normal range in weeks 1 to 12, but there were no colic symptoms with any of the treatments and there was no statistically significant difference between the groups (p>0.05). When feeding concentrate feed at 2.5% of body weight, it was assumed that trying to feed it several times per day would help to prevent colic; however, there was no difference in weight gain, blood characteristics, and physiological characteristics in accordance with the number of feeding times.

Effect of Different Cooling System on Performance and Hair Cortisol on Sows under Heat Stress (고온기 분만사 내 냉방 시설의 종류가 모돈의 번식성적 및 스트레스 지표에 미치는 영향)

  • Oh, Seung-Min;Choi, Yo-Han;Kim, Dong-Woo;Ha, Sang-Hun;Kim, Jo-Eun;Jung, Hyun-Jung;Kim, Jin-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.160-168
    • /
    • 2021
  • This study was undertaken to determine the effect of different cooling systems on the performance and hair cortisol of sows under heat stress. During a 21-day experiment, a total of 40 multiparous sows (Landrace×Yorkshire; 242.84±2.89 kg) were allotted to 4 treatments, each with 10 replicates (1 sow per pen). The experimental treatments were CP (Cooling pad), AC (Air conditioner), SC (Snout cooling), and MS (Mist spray). We observed an increase in the average daily feed intake during lactation (p<0.05) in the CP and AC treatment groups. AC treatment had the highest (p<0.05) and SC treatment had the lowest (p<0.05) piglet weight at weaning. During lactation, sows administered SC and MS treatments had higher (p<0.05) hair cortisol accumulation, as compared with the AC and CP treatments. Hair cortisol accumulation in piglets during lactation was highest with MS treatment (p<0.05), and lowest after CP treatment (p<0.05). MS treatment had the highest (p<0.05), and AC treatment had the lowest (p<0.05) respiratory rate and rectal temperature during lactation. In conclusion, our results indicate that a cooling pad and air conditioning cooling system increases the productivity of a sow, as compared to snout cooling and mist spray cooling systems.

Thermal Dynamics of Core and Periphery Temperature during Treadmill Sub-maximal Exercise and Intermittent Regional Body Cooling (트래드밀에서의 최대하 부하 운동과 간헐적 부위별 인체 냉각 시 심부와 말초 부위의 체온 변화)

  • Lee, Joo-Young;Koscheyev, Victor S.;Kim, Jung-Hyun;Warpeha, Joe M.
    • Journal of Korean Living Environment System
    • /
    • v.16 no.2
    • /
    • pp.89-100
    • /
    • 2009
  • The present study was designed to observe the thermal dynamics of core and skin temperatures during sub-maximal treadmill exercise; to investigate the effect of regional body cooling during short rest after the treadmill exercise on the thermal dynamics. Three conditions (No cooling, Head/Hand cooling, Leg cooling) were simulated in a climatic chamber at 24±1℃ and 50±5%RH. Subjects performed two bouts of treadmill exercise at a rate of 80%HRmax followed by rest. Body cooling with a hood, long gloves, and a blanket that circulated water set at 15℃ was assigned during two bouts of rest. The results showed that (1) rectal temperature (Tre) did not show significant difference between three conditions; (2) Skin temperatures had specific features, depending on body regions. In particular, the initial fall phenomena of skin temperatures at the onset of exercise were noteworthy in the chest, thigh, calf, and finger tip. Of these, the most significant initial fall was found in finger temperature (Tfing). (3) During the period of the initial fall in skin temperatures, Tre gradually increased. (4) The magnitude of the fall of Tfing at the onset of 2nd running was on average 4.8, 5.1 and 3.4℃ for Control, HH cooling, and Leg cooling, respectively (p<0.05). The initial drop of Tfing at the onset of running was maintained for an average of 8.1, 7.9 and 6.3 minutes for Control, HH cooling, and Leg cooling, with no significant differences. In conclusion, the initial fall phenomena at the onset of treadmill exercise reflected non-thermal factors, as opposed to internal thermal status. The magnitude of the initial fall in Tfing was affected by legs cooling. Therefore, the initial fall phenomenon should be considered when interpreting the thermal status of the shell during heavy works/exercises that assigned with intermittent regional body cooling.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF