• Title/Summary/Keyword: Recovery technology

Search Result 3,146, Processing Time 0.042 seconds

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.

Monitoring Methylmercury in Abyssal Fish (심해성 어류 중 메틸수은 모니터링)

  • Kim, Seong-Cheol;Jang, Jin-Wook;Kim, Hyun-Ah;Lee, Sang-Ho;Jung, Young-Ji;Kim, Ji-Yeon;Ahn, Jong-Hoon;Park, Eun-Hye;Ko, Yong-Seok;Kim, Dong-Sul;Kim, Sang-Yub;Jang, Young-Mi;Kang, Chan-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.383-389
    • /
    • 2010
  • The aim of this study was to determine the methylmercury (MeHg) levels in abyssal fish species. The MeHg in the fishes was extracted with hydrochloric acid and toluene and then purified using an L-cysteine solution. The extract was analyzed with a gas chromatography-electron capture detector (GC-${\mu}ECD$) with a thermon Hg-capillary column. The detection limit and the recovery of the method were 0.002 and 84.2-98.5% (mean, 93.4%), respectively. The MeHg content in 492 abyssal fishes ranged from 0.037 to 2.009 mg/kg. The levels of MeHg [range, mg/kg (mean)] were significantly dependent on fish species and presented as the following; 0.157-2.009 (0.546) in Scalloped hammerhead shark, 0.211-0.878 (0.501) in Blue shark, 0.121-0.993 (0.482) in Spiny dogfish, 0.243-0.658 (0.397) in Salmon shark, 0.074-1.958 (0.353) in Blacktip shark, 0.038-0.807 (0.302) in Southern hake, 0.099-0.511 (0.300) in Scorpion fish, and 0.037-0.133 (0.067) in Ling. The monitoring results showed that the estimated weekly intake of MeHg from sharks, Southern hake, and Ling were lower than the provisional tolerable weekly intake recommended by the Joint FAO/WHO expert committee on food additives.

Method Development for the Sample Preparation and Quantitative Analysis of Synthetic Colors in Foods (식품 중 식용타르색소의 시료별 전처리방법 확립 및 함량 분석)

  • Park, Sung-Kwan;Lee, Tal-Su;Park, Seung-Kook
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.893-899
    • /
    • 2004
  • Method for sample preparation and quantitative analysis of 19 permitted and non-permitted synthetic colors in foods was developed based on reversed-phase ion-pairing high performance liquid chromatography. For color extraction of samples, deionized water was added, and pH was appropriately adjusted with 1% ammonia water. Any undissolved matters were extracted with 50% ethanol or 70% methanol. Lipid in snacks was first removed using n-hexane with centrifugation, water was added to extract colors, followed by clean-up and concentration using Sep-Pak $C_{18}$ cartridge. Recovery efficiencies at known concentrations of 19 standard food colors spiked into foods were in 90.3-97.9% range far soft drink, 79.2-101.9% for candy, 84.1-103.4% for jelly, 86.4-100.8% for chewing gum, 83.5-103.4% for ice cream, and 78.5-95.6% for snack.

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

Estimation of Rumen By-pass Rate of Chromium-methionine Chelates by Ruminal Bacteria Analysis (반추미생물 분석에 의한 Chromium-methionine Chelate의 반추위 By-pass율 추정)

  • Kim, C.H.;Park, B.K.;Park, J.G.;Kim, H.S.;Sung, K.I.;Shin, J.S.;Ohh, S.J.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.759-768
    • /
    • 2005
  • The study was designed to estimate the in vitro rumen by-pass rate of both chromium methionine chelate as an organic supplement and $ClCl_3$ as an inorganic supplement. Rumen by-pass rates of the supplements were evaluted by comparing ruminal metabolites in rumen fluid and Cr and methionine contents in the body of ruminal microorganism. For in vitro digestion examination, basic nutrients for ruminal microbes were supplied with 7g(DM) of feed, 2g of rice straw, and 2g of corn silage per each incubation jar. Three treatments including Control(no supplementation of Cr), T1(1000ppb supplementation of $ClCl_3$) and T2(chromium methionine chelate supplementation equivalent to 1000ppb of Cr content) were prepared with five replications per each treatment. pH of T2 was lower than that of Control and T1 regardless of incubation time. Ammonia content was higher in T2 than in Control and T1 during first 6 hours of incubation. However, the ammonia content in Control was remained low after 6 hours. Total volatile fatty acids(VFA) content in control was increased constantly as incubation time was extended. Therefore, VFA content in T1 and T2 were significantly lower (P<0.05) than those of Control. Dry matter recovery rate by ruminal microorganism was the lowest in T1, however ruminal microbial population was increased most efficiently in T2 during 12 hours of in vitro incubation. Cr concentrations in the body of ruminal microbes were not different(P>0.05) between Control and T2, but it was significantly high in T1(P<0.05). Contents of methionine and cystine in ruminal microbes also were not different between Control and T2(P>0.05), but it was relatively low in T1. Based on the above results, the chromium methionine chelate was believed to by-pass rumen and could remain intact until it reaches small intestine compared to inorganic chromium. This results implies that chromium methionine chelate could be more effective to function in the small intestine of ruminant animals.

Establishment of an Analytical Method for Novobiocin in Livestock Products Using HPLC-UVD (HPLC-UVD를 이용한 축산식품 중 Novobiocin의 시험법 확립)

  • Park, Hee-Ra;Kwon, Chan-Hyeok;Lee, Jong-Goo;Kim, Hyung-Soo;Chae, Young-Sik;Oh, Jae-Ho;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.263-268
    • /
    • 2012
  • Novobiocin is a coumarin-containing antibiotic, and has a longer half-life in various animals than other veterinary medicines. A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in chicken, beef and milk has been developed and validated. The separation condition for HPLC/UVD was optimized by a MG II $C_{18}$ (4.6 mm $ID{\times}250$ mm, 5 ${\mu}m$) column with 0.1% formic acid in $H_2O$/0.1% formic acid in Acetonitrile (40/60, v/v) as the mobile phase at a flow rate of 1.0 mL/min and the detection wavelength was set at 340 nm. Residues were extracted from tissue by blending with methanol. After liquid-liquid partitioning, lipid materials were removed with n-hexane and purification as Silica (1 g, 6 mL) cartridge with 10 mL acetone/dichloromethane (10/90, v/v). Limit of quantification and linearity performed by the analytical method were 0.02 mg/kg and 0.999 ($r^2$), and the recovery range was $88.8{\pm}5.6-100.3{\pm}4.4$, $88.8{\pm}7.2-97.0{\pm}3.2$ and $88.1{\pm}4.3-92.8{\pm}3.6%$. It is expected that this analytical method with regards to novobiocin in chicken, beef and milk could be applied as an official method to administer food safety on veterinary medicines.

Determination of the Levels of Bisphenol A Diglycidyl Ether (BADGE), Bisphenol F Diglycidyl Ether (BFDGE) and Their Reaction Products in Canned Foods Circulated at Korean Markets (캔 제품의 bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) 유도체 및 분해산물 분석법)

  • Kim, Hee-Yun;Lee, Jin-Sook;Cho, Min-Ja;Yang, Ji-Yeon;Baek, Ji-Yun;Cheong, So-Young;Choi, Sun-Hee;Kim, Young-Seon;Choi, Jae-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • Bisphenol A diglycidyl ether (BADGE) and bisphenol F diglycidyl ether (BFDGE) were obtained by a polymerization reaction of epichlorohydrin (ECH) with bisphenol A (BPA) or bisphenol F (BPF). These compounds are commonly used as monomers or additives such as a polymerization stabilizer and a hydrochloric acid scavenger of epoxy resin, polyvinyl chloride (PVC)-containing organosols and polyester lacquers, that are applied to the internal surface of most canned foods to impart chemical resistance. The unreacted BADGE, BFDGE and their reaction products migrating from epoxy resin, PVC-containing organosol and/or polyester lacquer-based food packaging materials into the foods have recently become an issue of great concern because of increased customer demand for safety. This study was conducted to develop a rapid and sensitive simultaneous analysis method based on HPLC/FLD and HPLC/APCI-mass and to evaluate the concentration of BADGE, BFDGE and their metabolites, BADGE $H_2O$, BADGE $2H_2O$, BADGE HCl, BADGE 2HCl, BADGE HCl $H_2O$, BFDGE $H_2O$, BFDGE $2H_2O$, BFDGE HCl, BFDGE 2HCl and BFDGE HCl $H_2O$ for 133 canned food samples. The method provided a linearity of 0.9997-0.9999, a limit of detection of $0.01-0.13\;{\mu}g/mL$, a limit of quantitation of $0.03-0.44\;{\mu}g/mL$ and a recovery (%) of 85.64-118.18. The number of samples containing BADGE, BFDGE or their metabolites were: 28/133 (21.1%), with levels of 0.400-0.888 mg/kg being observed for aqueous foods (19/133) and 0.093-0.506 mg/kg being observed for oily foods (9/133).

Physicochemical Characteristics of Galactomannan by Fractionation to Evaluate Heterogeneity (불균일 성질을 평가하기 위한 분획화된 galactomannan의 이화학적 특성)

  • Kim, Kyeong-Yee;Lee, Eun-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.428-433
    • /
    • 2013
  • Heterogenous samples of locust bean gum (galactomannan) were prepared into homogeneous substances. Locust bean gum was fractioned using ammonium sulfate (14.11-23.08%, w/w). The intrinsic viscosity was obtained by extrapolating reduced viscosity versus concentration by using an Ubbelohde viscometer. The ranges of intrinsic viscosity for fractions that not included protein (F3-F6) and fractions that included protein (F1-F2) were 9.89-8.10 and 8.44-4.59, respectively. Values for Huggins' coefficient (k'), which depends on physical interactions, were 0.46-0.78. Increasing ammonium sulfate concentration was associated with a weak trend towards lower molecular weight and intrinsic viscosity by size-exclusion chromatography (SEC): $M_w$ ranged from 674 to 617 kg/mol and [${\eta}$] from 9.80 to 8.10 dL/g between F3 and F6. The evaluations of those fractions by using SEC and the Ubbelohde viscometer produced very similar values, as predicted. We verified the application of a gradient of ammonium sulfate to precipitate locust bean gum into fractions of different molecular size and show structural variations.

Evaluation of Residual Pesticides in Commercial Agricultural Products Using LC-MS/MS in Korea (LC-MS/MS를 이용한 한국에서 유통되는 농산물의 잔류 농약 평가)

  • Lee, Hwa-Mi;Hu, Soo Jung;Lee, Hyun-Sook;Park, Seung Young;Kim, Nam-Sun;Shin, Yong Woo;Choi, Keun Hwa;Kim, Sung Il;Nam, Seul Yi;Cho, Dae Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.391-402
    • /
    • 2013
  • Pesticide residues in agricultural products in Korea were evaluated to create a data base to inform food policy. Pesticide residues were investigated in 17 commodities collected from 9 provinces in 2012. Our analytical method of multiresidue analysis, involved the analysis of individual recovery, linearity, limit of detection, and limit of quantitation of 60 pesticides in six matrices. The pesticides, including acetamiprid and forchlorofenuron, were evaluated in 358 agricultural samples by liquid chromatography/tandem mass spectrometry. Twenty three pesticides were detected from 67 samples. The results showed that the ratio of estimated daily intake to acceptable daily intake was 0.00009-0.0861% by the intake assessment, which means that residual pesticides in agricultural products in Korea are properly controlled.