• Title/Summary/Keyword: Recovery coefficient

Search Result 498, Processing Time 0.027 seconds

Effects of Treatment Process and Brushing Condition on Mechanical Properties of Brushed Fabrics (II) -Drapability and Wrinkle Recovery of Brushed Fabrics- (기모직물의 가공공정 및 기모횟수가 역학적 특성치에 미치는 영향(II) -드레이프성 및 방추성을 중심으로-)

  • Kwon, Hyun-Sun;Kwon, Oh-Kyung;Sung, Su-Kwang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.5
    • /
    • pp.595-601
    • /
    • 1994
  • This study was accomplished to investigate drape coefficient and wrinkle recovery of brushed fabrics according to treatment processes and brushing conditions. For this study, grey fabrics of blended ratio of polyester 65% : cotton 35% were bleached and dyed. These fabrics were then brushed 1, 3, 5 and 7 times. Drape coefficient and wrinkle recovery of brushed fabrics were measured by drape tester and shirley crease recovery tester respectively. The experimental results were analysed statistically to relate mechanical properties, handle, drapability, and wrinkle recovery 1) Drape coefficients of dyed fabric showed lower values and wrinkle recovery showed higher ones than those of bleached and dyed fabrics. Especially dyed fabric brushed 3 times showed good appearance and form stability. 2) Considering the blocked properties that contribute to the drape coefficient and wrinkle recovery of brushed fabrics, bending and shearing properties had a high degree of correlation with brushed fabrics, and 2HB/W showed a high positive correlation with drape coefficient and a high negative correlation with wrinkle recovery.

  • PDF

Implementation of Blind Source Recovery Using the Gini Coefficient (Gini 계수를 이용한 Blind Source Recovery 방법의 구현)

  • Jeong, Jae-Woong;Song, Eun-Jung;Park, Young-Cheol;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • UBSS (unde-determined blind source separation) is composed of the stages of BMMR (blind mixing matrix recovery) and BSR (blind source recovery). Generally, these two stages are executed using the sparseness of the observed data, and their performance is influenced by the accuracy of the measure of the sparseness. In this paper, as introducing the measure of the sparseness using the Gini coefficient to BSR stage, we obtained more accurate measure of the sparseness and better performance of BSR than methods using the $l_1$-norm, $l_q$-norm, and hyperbolic tangent, which was confirmed via computer simulations.

A General Solution of Determining Storage Coefficient From Multi-Step Pumping Test Recovery Data

  • Jin-Yong Lee;Kang-Kun Lee
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.20-23
    • /
    • 2000
  • A general solution for determining the storage coefficient from multi-step pumping test recovery data is suggested. This solution is essentially based on the method of Banton and Bangoy (1996), which used single-step pumping test recovery data. The suggested solution can be applied to any-step pumping test recovery data. We have demonstrated the applicability of the general solution to single-, double-, and triple-step pumping and/or step-drawdown test data partially described in Lee and Lee (1999). The estimates of storage coefficient as well as transmissivity are well consistent with the values from other methods for pumping phase data.

  • PDF

Numerical Analysis of the Static Pressure Recovery Characteristics in Conical Diffuser by Inserting a Strut (스트러트를 삽입한 원추형 디퓨져의 압력회복 특성)

  • Kim, Se-Hyun;Seo, Jong-Soo;Shim, Kyu-Jin;Yi, Chung-Seub;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1613-1618
    • /
    • 2004
  • Diffuser is an important fluid-mechanical equipment to convert kinetic energy into pressure energy. Many of the experimental and theoretical researches have been done in a diffuser but the understanding of energy transfer and detailed mechanism of energy dissipation is unclear. In this study, computations were performed using a numerical method with SIMPLE algorithm for conical diffuser with various diffuser angles and diffuser lengths. Also, we investigated the pressure recovery coefficient in conical diffuser by inserting strut. In this paper, we showed that the strut can cause a rising pressure recovery.

  • PDF

Partitioning of Recombinant Human Interleukin-2 in a Poly(ethylene glycol)-Dextran Aqueous Two-Phase System

  • Lee, In-Young;Lee, Sun-Bok
    • Journal of Microbiology and Biotechnology
    • /
    • v.2 no.2
    • /
    • pp.135-140
    • /
    • 1992
  • The partitioning of recombinant human interleukin-2(rhII-2) in PEG 8000-dextran 38800 aqueous two-phase system has been investigated using three different sources of rhIL-2. In the case of pure rhIL-2, the solubility in a PEG-dextran two-phase system was low and most of rhIL-2 was partitioned into the bottom phase. For the recovery of rhIL-2 from insoluble protein aggregates, the inclusion bodies of recombinant E. coli were solubilized by the treatment with sodium dodecyl sulfate (SDS). The addition of SDS significantly enhanced not only the solubility of rhIL-2 but also the partitioning of rhIL-2 to the top phase. When the ratio of SDS to rhIL-2 was 2.0, the partition coefficient(K) and the recovery yield(Y) at the top phase were 4.5 and 88%, respectively, at pH 6.8. In order to reduce the recovery steps further, SDS was directly added to the intact recombinant E. coli cells and then partitioned into the PEG/dextran aqueous two-phase system. The observed partition coefficient ($K{\cong{3.0$) and recovery yield ($Y{\geq}80%$ )of this method were comparable to the rhIL-2 recovery from insoluble protein aggregates. The results obtained in this work indicate that PEG-dextran two-phase partitioning might provide a simple way for the recovery and partial purification of recombinant proteins which are produced as inclusion bodies.

  • PDF

The Development of a Mental Disorder Recovery Scale (정신장애인의 회복측정도구 개발)

  • Lee, Jeong-Sook;Lee, Sun-Young
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.639-647
    • /
    • 2013
  • This paper is a methodological research aimed at developing a mental disorder recovery scale (MDRS) and testing its validity and reliability. After three sessions of factor analysis, a total of three factors using an Eigen value of 1.0 or more were drawn. The explanatory power was found to be 58.1%. All the items met the criteria for communality and factor loading with no item removed, and, ultimately, 25 items were selected. Criterion-related validity test showed that Pearson's correlation coefficient was significant at .71 (p<.01) with significant correlation with each factor (p<.01). The reliability test showed that Cronbach's ${\alpha}$ coefficient was .95 and that Cronbach's ${\alpha}$ coefficient for each factor ranged from .87 to .93. MDRS, which was developed in this study and possessing 3 factors and 25 items, had both its validity and reliability confirmed; therefore, the developed scale would be useful to evaluate the recovery of individuals with mental disorder.

Flow Characteristics of Two Types of Overhung Compressor Volute for Automobile Turbocharger (자동차용 터보차저의 오버헝 압축기 볼류트의 두 형태에 대한 유동장 특성)

  • Tianjun, Zhou;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.25-30
    • /
    • 2014
  • The flow characteristics of two types of overhung compressor volutes for automobile turbochargers were analyzed numerically using commercial software. For obtaining high performance from a volute, it is necessary that the volute have a high pressure recovery coefficient and a low loss coefficient. We investigated the flow characteristics of two types of overhung compressor volutes with a fixed diffuser inlet angle of $24^{\circ}$ and a mass flow rate of 0.055 kg/s. The first type is a volute with one-arc cross section (type 1) and the second type is with three-arc cross section (type 2). Our results showed that between the two types of volutes, type 2 had the higher pressure recovery coefficient and the lower loss coefficient along the entire angular position.

Study on the Ethanol Recovery Process using Dircet Contact Heat Exchange (고온의 기포접촉에 의한 에탄올 회수공정에 관한 연구)

  • Lee, Won-Young;Yeo, Sang-Do;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.176-180
    • /
    • 1995
  • Direct contact heat exchange (DCHE) method has been employed to investigate the separation of ethanol from dilute aqueous solutions. Bubbles at high temperature were dispersed into a continuous liquid phase, generating temperature gradient in air-liquid interface, which causes heat and mass transfer accordingly. The experiments were performed in the ranges of jet regime air flow. The air-water stripping coefficient increased $5{\sim}10,\;and\;1{\sim}1.5$ times as temperature and air flow rate increased, respectively. The recovery ratio based on the initial ethanol concentration reached into 80% at the air flow rate of 84.88 m/min. The initial ethanol concentration showed little effect on the stripping coefficient and the recovery ratio.

  • PDF

A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect (부분 체적 효과에서 회복 계수를 이용한 보정 전과 후 SUV의 비교 분석)

  • Ko, Hyun-Soo;Park, Soon-Ki;Choi, Jae-Min;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2011
  • Purpose: The partial volume effect occurs because of limit of the spatial resolution. It makes partial loss of intensity and causes SUV to be lower than it should actually be. So the purpose of this study is to calculate recovery coefficient for correcting PVE from phantom study and to compare before and after SUV correction applying to PET/CT examination. Materials and Methods: The flangeless Esser PET phantom consisting of four hot cylinders was used for this study. All of the hot cylinders were filled with FDG solution of 20.72 MBq per 1000 ml, and the phantom background was filled with FDG solution of different concentrations (33.30, 22.20, 16.65 MBq per 6440 ml) to yield H/B ratios of around 4:1, 6:1 and 8:1. Using the Biograph Truepoint 40(SIEMENS, Germany), we applied recovery coefficient method to 30 patients who were diagnosed with lung cancer after PET/CT exam. And then we analyzed and compared SUV before and after correcting partial volume effect. Results: The smaller the diameter of hot cylinder becomes, the more recovery coefficient decreased. When we applied recovery coefficient to clinical patients and compared SUV before and after correcting PVE, before the correction all lesions gave an average max SUV of 7.83. And after the correction, the average max SUV increases to 10.31. The differences in the max SUV between before and after correction were analyzed by paired t test. As a result, there were statistically significant differences (t=7.21, p=0.000). Conclusion: The SUV for quantification should be measured precisely to give consistent information of tumor uptake. But PVE is one of factors that causes SUV to be lower and to be underestimated. We can correct this PVE and calculate corrected SUV using the recovery coefficient from phantom study. And if we apply this correction method to clinical patients, we can finally assess and provide quantitative analysis more accurately.

  • PDF

A Study on the Performance Prediction of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능예측에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Jin-Hyuck
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.294-299
    • /
    • 2005
  • In order to control indoor air quality and save energy. it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. Paper heat exchanger can recover $50{\sim}70$ of the enthalpy difference between supply and exhaust air. The purpose of this research is to obtain the experimental correlations for the friction factor, heat transfer coefficient, mass transfer coefficient and permeance of paper heat exchanger, which can be used for the performance prediction of the paper heat exchanger. Pressure drop at various velocities and heat transfer rate at various dry-bulb temperatures, relative humidities, and specific humidities are measured to make experimental correlations. The results of prediction using correlations show fairly good agreement with experimental data.

  • PDF