• Title/Summary/Keyword: Recovery Technology

Search Result 3,154, Processing Time 0.038 seconds

A Nested Session Control for Fault-Recovery Agent on Industry Safety Environment (산업 안전 환경에서 결함 복구 에이전트를 위한 네스티드 세션 관리)

  • Ko, Eung-Nam
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.1
    • /
    • pp.74-79
    • /
    • 2010
  • This paper explains the design and implementation of nested session management based the FRA(Fault Recovery Agent). FRA is a system that is suitable for recovering software error for multimedia remote control based on industry safety environment. In this paper, we discuss a method for increasing reliability through organization of nested session.

Application of Reversed-Phase Solid Phase Extraction for the HPLC Analysis of Microcystins in Water (다량 시료중 마이크로시스틴의 농축 및 분석)

  • Kim, Myeong-Hee;Kim, Tae-Seung;Kim, Tae-Keun;Park, Sun Ku
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.399-402
    • /
    • 2000
  • To determine the concentrations of microcystins present in lake water or in tap water using high performance liquid chromatography, it is necessary to concentrate a large volume of water samples (about 20 L) into very small volume (0.1-0.3 mL). Concentration can be conveniently done when disc type solid phase extraction (SPE) apparatus is used. Using this apparatus we have investigated the recovery rates of three kinds of microcystins, RR, YR, LR. The recovery rates were relatively low and the reproducibilities were not good either. It is expected, however, that the appropriate selection of the disc conditioning and eluting solvents and reproducible reconcentration process after SPE will improve both the recovery rates and the reproducibilities.

  • PDF

Disaster Recovery Priority Decision of Total Information System for Port Logistics : Fuzzy TOPSIS Approach (항만물류종합정보시스템의 재난복구 우선순위결정 : 퍼지 TOPSIS 접근방법)

  • Kim, Ki-Yoon;Kim, Do-Hyeong
    • Journal of Information Technology Services
    • /
    • v.11 no.3
    • /
    • pp.1-16
    • /
    • 2012
  • This paper is aimed to present a fuzzy decision-making approach to deal with disaster recovery priority decision problem in information system. We derive an evaluation approach based on TOPSIS(Technique for Order Performance by Similarity to Ideal Solution), to help disaster recovery priority decision of total information system for port logistics in a fuzzy environment where the vagueness and subjectivity are handled with linguistic terms parameterized by trapezoidal fuzzy numbers. This study applies the fuzzy multi-criteria decision-making method to determine the importance weight of evaluation criteria and to synthesize the ratings of candidate disaster recovery system. Aggregated the evaluators' attitude toward preference, then TOPSIS is employed to obtain a crisp overall performance value for each alternative to make a final decision. This approach is demonstrated with a real case study involving 4 evaluation criteria(system dependence, RTO, loss, alternative business support), 7 information systems for port logistics assessed by 5 evaluators from Maritime Affairs and Port Office.

VLSIs for the MAC TV System - Part III. A Data and Clock Recovery Circuit (MAC 방식 TV 시스템용 IC의 설계 - III. 신호 및 클럭 복원기)

  • Moon, Yong;Jeong, Deog-Kyoon
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.12
    • /
    • pp.1644-1651
    • /
    • 1995
  • A data and clock recovery integrated circuit for MAC (Multiplexed Analog Component) TV standard is described. The chip performs the recovery of a system clock from a digitally encoded voice signal, clamping of a video signal for DC-level restoration, and precise gain control of a video signal in the presence of a large amplitude variation. A PLL (Phase Locked Loop) is used for timing recovery and a new gain control circuit is proposed which enhances its accuracy and dynamic range by employing two identical four-quadrant analog multipliers. The chip is designed in full custom with 1.5um BiCMOS technology, and layout verification is completed by post-simulation with the extracted circuit.

  • PDF

Analysis on the Performance Test Results of Heat Pump for the Closed Cooling Water Heat Recovery on Combined Thermal Power Plant (복합화력발전소의 냉각수 배열회수를 위한 히트펌프의 성능평가)

  • Lee, Sung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.43-48
    • /
    • 2016
  • This study proves successes of Energy Service Company (ESCO) business by heat pump performance test. The purpose of ESCO business is recover investment costs through saving energy from installation of energy reduction facility. The most important technology assessment items are heat recovery and generator output. Experimental result shows that increase quality of heat recovery (11.52Gcal/h), while decrease generator output (0.234kw). In its final analysis, the ESCO business is successful according to our data.

Effects of Welding Parameters on Weld Metal Strength and Recovery of Alloying Elements in FCAW (FCAW에서 용접변수에 따른 용접금속 강도 및 와이어 합금원소의 회수율 변화)

  • Jung, Dong-Hee;Bang, Kook-Soo;Park, Chan;Chang, Woong-Sung;Park, Chul-Gyu
    • Journal of Welding and Joining
    • /
    • v.26 no.2
    • /
    • pp.69-74
    • /
    • 2008
  • 590MPa grade weldable steels were gas metal arc welded with flux cored wires. Welding parameters such as current, voltage, and speed were varied independently. Effects of each parameter on the strength and chemical composition of weld metal were investigated. Increase of voltage caused decrease of weld metal tensile strength due to the low recovery of alloying elements such as carbon and manganese. On the contrary, increase of current and speed resulted in increase of weld metal strength because of higher recovery of the alloying elements.

High Performance and Low Cost Single Switch Current-fed Energy Recovery Circuits for AC Plasma Display Panels

  • Han Sang-Kyoo;Youn Myung-Joong
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.253-263
    • /
    • 2006
  • A high performance and low cost single switch current fed energy recovery circuit (ERC) for an alternating current (AC) plasma display panel (PDP) is proposed. Since it is composed of only one power switch compared with the conventional circuit consisting of four power switches and two large energy recovery capacitors, the ERC features a simpler structure and lower cost. Furthermore, since all power switches can be switched under soft switching operating conditions, the proposed circuit has desirable merits such as increased reliability and low switching loss. Specifically, there are no serious voltage notches across the PDP with the aid of gas discharge current compensation, which can greatly reduce the current stress of all inverter switches, and provide those switches with the turn on timing margin. To confirm the validity of proposed circuit, its operation and performance were verified on a prototype for 7-inch test PDP.

ROSA/LSTF test and RELAP5 code analyses on PWR steam generator tube rupture accident with recovery actions

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.981-988
    • /
    • 2018
  • An experiment was performed for the OECD/NEA ROSA-2 Project with the large-scale test facility (LSTF), which simulated a steam generator tube rupture (SGTR) accident due to a double-ended guillotine break of one of steam generator (SG) U-tubes with operator recovery actions in a pressurized water reactor. The relief valve of broken SG opened three times after the start of intact SG secondary-side depressurization as the recovery action. Multi-dimensional phenomena specific to the SGTR accident appeared such as significant thermal stratification in a cold leg in broken loop especially during the operation of high-pressure injection (HPI) system. The RELAP5/MOD3.3 code overpredicted the broken SG secondary-side pressure after the start of the intact SG secondary-side depressurization, and failed to calculate the cold leg fluid temperature in broken loop. The combination of the number of the ruptured SG tubes and the HPI system operation difference was found to significantly affect the primary and SG secondary-side pressures through sensitivity analyses with the RELAP5 code.

Cesium and strontium recovery from LiCl-KCl eutectic salt using electrolysis with liquid cathode

  • Jang, Junhyuk;Lee, Minsoo;Kim, Gha-Young;Jeon, Sang-Chae
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3957-3961
    • /
    • 2022
  • Deposition behaviors of Sr and Cs in various liquid cathodes, such as Zn, Bi, Cd, and Pb, were examined to evaluate their recovery from LiCl-KCl eutectic salt. Cations in the salt were deposited on the liquid cathode, exhibiting potential of -1.8 to -2.1 V (vs. Ag/AgCl). Zn cathode had successful deposition of Sr and exhibited the highest recovery efficiency, up to 55%. Meanwhile, the other liquid cathodes showed low current efficiencies, below 18%, indicating LiCl-KCl salt decomposition. Sr was recovered from the Zn cathode as irregular rectangular SrZn13 particles. A negligible amount of Cs was deposited on the entire liquid cathode, indicating that Cs was hardly deposited on liquid cathodes. Based on these results, we propose that liquid Zn cathode can be used for cleaning Sr in LiCl-KCl salt.

'Brine Management through brine mining of trace metals' for developing Secondary sources of nuclear fuel

  • T.L. Prasad
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.674-680
    • /
    • 2023
  • The brine and seawater are important and largely untapped sources of critical trace metals and elements. The coupling of selective recovery of trace metals from seawater/brine with desalination plants gives an added advantage of energy credits to desalination plants and as well as reduce the cost of desalinated water. In this paper, status review on recovery of important trace metals and other alkali metals from seawater is presented. The potential of Indian desalination plants for recovery of trace metals, based on recovery ratio of 0.35 is also highlighted. Studies carried out by the process based on adsorption using Radiation Induced Grafted (RIG) polymeric adsorbents and then fractional elutions are presented. The fouling factors due to bio fouling and dirt fouling have been estimated for various locations of interest through field trails. The pay loader in the form of compact Contactor Assembly with minimum pressure drop, for loading specially designed radiation grafted sorbent in leaflet form has been briefed, as required for plant scale facility. The typical conceptual process design details of farm assembly of project CRUDE are described.