• 제목/요약/키워드: Recovery Technique

검색결과 939건 처리시간 0.033초

Minimally invasive distal biceps tendon repair: a case series

  • Paul Jarrett;Anna-Lisa Baker
    • Clinics in Shoulder and Elbow
    • /
    • 제26권3호
    • /
    • pp.222-230
    • /
    • 2023
  • Background: Distal biceps tendon repairs are commonly performed using open techniques. A minimally invasive distal biceps tendon repair technique using a speculum and hooded endoscope was developed to improve visualization, reduce soft-tissue dissection, and minimize complications. This paper describes the technique and reports the outcomes of 75 minimally invasive distal biceps tendon repairs. Methods: The operation reports and outcomes of 75 patients who underwent distal biceps tendon repair using this technique between 2011 and 2021 were retrospectively reviewed. Results: Median time to follow-up was 12 months (interquartile range [IQR], 6-56 months). Primary outcomes were function as measured by the Disabilities of Arm, Shoulder and Hand Score (DASH) questionnaire, and rate of complications. Median DASH score was 1.7 of 100 (IQR, 0-6.8). There were 2 of 75 (2.7%) re-ruptures of the distal tendon. There were no cases of vascular injury, proximal radius fracture, or posterior interosseous nerve, median, or ulnar nerve palsy. Conclusions: In this series, minimally invasive distal biceps repair was safe and effective with a low rate of major complications. Recovery of function, as indicated by low DASH scores, was satisfactory, and inconvenience during recovery was minimized. Level of evidence: IV.

임플란트 수술을 위한 미다졸람 정주와 아산화질소 흡입 병용 진정법의 효과와 안전성에 대한 전향적 무작위 대조군 연구 (A Prospective, Randomized and Controlled Study for the Efficacy and Safety of Sedation Technique for Implant Surgery by Combining Nitrous Oxide and Intravenous Midazolam)

  • 전승환;정신혜;김광수;전상호;황경균;박창주
    • 대한치과마취과학회지
    • /
    • 제12권2호
    • /
    • pp.69-74
    • /
    • 2012
  • Background: The purpose of this study is to investigate the efficacy and safety of the sedation technique for implant surgery by combining the use of inhalation of nitrous oxide/oxygen with intravenous midazolam. Methods: Patients requiring surgery for the placement of dental implants were randomly allocated to two groups receiving intravenous midazolam or a combined technique using nitrous oxide/oxide and intravenous midazolam. Safety parameters, cooperation scores, anxiety scales, total amount of midazolam administered and recovery time were recorded and compared. Results: There were a statistically significant reduction in the amount of midazolam required to achieve optimal sedation (P<0.01), an overall significant reduction in recovery time (P<0.01), a significant reduction in anxiety scales (P<0.05), and a significant improvement in cooperation (P<0.05) and peripheral oxygen saturation (P<0.05) when a combined technique of inhalational $N_2O/O_2$ and midazolam was used. Conclusions: For implant surgery, this combining sedation technique could be safe and reliable, demonstrating reduction of total dose of midazolam and level of patient's anxiety and improvement in patient's recovery and cooperation.

증류법을 이용한 모의 방사성폐기물 중 129I 의 정량 (Determination of 129I in simulated radioactive wastes using distillation technique)

  • 최계천;송병철;한선호;박용준;송규석
    • 방사성폐기물학회지
    • /
    • 제9권3호
    • /
    • pp.141-148
    • /
    • 2011
  • 방사성폐기물이 처분장에 인도 될 때 주요 방사성 핵종의 방사능 농도를 규명 하도록 방사성폐기물 인도 규정에 명시되어 있다. 저준위 방사성폐기물 시료의 경우 측정된 방사능 농도가 최소검출 방사능 농도(MDA: Minimum dectable activity) 이하의 값을 나타낼 경우가 많으며, MDA는 시료의 양, 바탕 값, 계측시간 및 계측효율 등에 따라서 달라지므로 MDA를 낮추기 위하여 가능한 많은 양의 시료를 취할 필요가 있다. 모의 잡고체 시료에 첨가된 요오드의 회수율을 결정하기 위한 방법으로서 모의 시료 중 비 방사성 요오드를 비휘발성 산으로 침출시킨 후 침출액을 직접 증발시키는 방법과 음이온 교환수지를 이용하I-를 흡착하여 분리하는 칼럼용리방법으로 측정하여 회수율을 비교한 결과, 증류법과 칼럼용리방법의 회수율은 각각 $86.5{\pm}0.9%$, $87.3{\pm}2.7%$로 나타났다. 증류법에 의한 모의 방사성 시료 중 $^{129}I$ 요오드의 회수율 및 MDA는 $84.6{\pm}1.6%$, $1.2{\times}10^{-4}Bq/g$로 각각 나타났으며, 분리공정을 단순화하고 많은 양의 시료를 취함으로써, 칼럼용리 방법의 단점을 보완하고 10배 이상 MDA를 낮출 수 있는 결과를 얻을 수 있었다.

파일럿 지료 조성설비를 이용한 폐 일회용 기저귀의 유용성분 회수에 관한 연구 (Studies on the Recovery of Useful Materials from Disposable Diaper Waste using Pilot Stock Preparation Units)

  • 이태주;남윤석;박정은;조준형;류정용;이호선
    • 펄프종이기술
    • /
    • 제47권4호
    • /
    • pp.66-75
    • /
    • 2015
  • Disposable diaper waste is consisted of plastic, fiber, and SAP (Super Absorbent Polymer). They are valuable to be used as raw materials of other products including plastic blocks and pulp mold. Nevertheless, disposable diaper waste have been disposed by landfill and incineration without recycling. Due to strict environmental regulations it is necessary to develop fractionation technique to recycle the disposable diaper waste. In this study the fractionation technique using pilot-scale stock preparation units was investigated. Process for separation of plastic and fibers from disposable diaper waste was composed by the combination of pilot-scale pulper, drum screen, screen and cleaner. Recovery rate of plastics and fiber was checked according to the various operating conditions. In drum screen, recovery rate of plastic was high when the cut size of disposable diaper waste was $5cm{\times}5cm$. The highest recovery rate of fiber was achieved with 0.3 mm slot screen. It is important to control the neutral state of SAP for improvement of recovery rate of fiber since SAP can be swelled easily in water. Therefore SAP can be controlled efficiently by the addition of calcium chloride into the pulper. Consequently recovery rates of plastics and fibers were over 90 and 80% under the optimum pilot operating conditions.

Quantitative Analysis of T1 Weighted Images due to Change in TI by Using the Inversion Recovery in 3.0T Brain MRI Examination

  • Han, Jung-Seok;Dong, Kyung-Rae;Chung, Woon-Kwan;Cho, Jae-Hwan;Shin, Jae-Woo;Kim, Young-Jae
    • Journal of Magnetics
    • /
    • 제17권2호
    • /
    • pp.158-162
    • /
    • 2012
  • Although 3.0T magnetic resonance imaging (MRI) has the advantages of a higher signal to noise ratio (SNR) and contrast than 1.5T MRI, there are limitations on the contrast between white and grey matter because of the long T1 recovery time when T1 images are obtained using the Spin Echo Technique. To overcome this, T1 weighted images are obtained occasionally using the inversion recovery (IR) technique, which employs a relatively long TR. The aim of this study was to determine the optimal TI in a brain examination when a T1 weighted image is obtained using the IR technique. Eight participants (male: 7, female: 1, average age: $34{\pm}14.11$) with a normal diagnosis were targeted from February 18, 2012 to February 27, 2012, and the contrast between white and grey matter as well as the contrast to noise ratio (CNRs) in each participant were measured. The CNRs of white matter and grey matter were highest at TI = 600, 650, 750, 900, 1050 and 1100 ms when the TR was 1100, 1400, 1700, 2000, 2300 and 2600 ms, respectively. Therefore, as the TIs were $44.425{\pm}0.877%$ of the TRs in the TR range of 1400-2300 ms, the optimal T1 weighted images that describe the contrast between white and grey matter can be obtained if the TIs are compensated for with $44.425{\pm}0.877%$ of the TRs in the time of setting TIs.

상완신경총 환자에서 최적의 자기공명영상 지방소거 기법에 관한 연구 : SPAIR, STIR 지방소거 중심으로 (A Study on Optimized MRI Fat-Saturation Technique for Brachial Plexus Patients : Focused on SPAIR and STIR Fat-Saturation)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제8권5호
    • /
    • pp.271-278
    • /
    • 2014
  • 상완신경총에서 STIR(short TI inversion recovery) 지방소거 강조영상과 SPAIR(spectral adiabatic inversion recovery) T2, T1 지방소거 강조영상기법을 비교 평가하여 최적의 지방소거 기법을 알아보고자 하였다. 총 30 명 상완신경총에 질환이 없는 정상인 지원자를 대상으로 3.0 T MRI 기기를 이용하여 검사를 하였고, 분석방법으로 세 기법에 대하여 SNR, CNR 및 4단계 점수로 평가를 하였다. 정량적 분석 결과로 SPAIR T1 기법에 대한 SNR, CNR 값은 상완신경총기시부($03.07{\pm}0.98$, $-2.25{\pm}0.54$), 상완신경총몸체($06.70{\pm}1.81$, $36.31{\pm}2.17$)에서 높은 값을 제공하였다 (p<0.05). 정성적 분석결과 상완신경총 묘출도와 지방소거 정도, 영상의 인공물은 SPAIR T1($3.2{\pm}0.70$, $3.6{\pm}0.51$, $3.4{\pm}0.10$)기법이 의미 있게 높게 나타났다(p<0.05).

연소 또는 소각 과정에서 발생하는 배기가스의 폐열 회수 설계 방법에 관한 연구 (Study on the Heat Recovery Design Methods for the Flue Gas from Combustion and Incineration Processes)

  • 이찬;정봉진
    • 청정기술
    • /
    • 제5권2호
    • /
    • pp.53-61
    • /
    • 1999
  • 대형 산업용 환경폐기물 처리 및 열병합 플랜트의 연소 및 소각 공정 후 발생하는 배기가스의 폐열회수장치 설계 방법을 제시하였다. 본 연구는 폐열회수장치의 기본 설계 개념을 폐열회수를 위한 보일러와 폐열을 이용한 증기 동력 사이클로 구성되는 것으로 가정하였고, 폐열회수장치에 필요한 각 구성요소들에 대한 모델링 기법과 그에 따른 설계 기준 및 설계 개념을 기술하였다. 또한 본 설계방법을 이용하여, 동일한 배기가스 조건에 대해, 폐열회수 보일러의 작동 압력 및 폐열회수 열교환기 설계에 따라 폐열회수장치의 열성능이 어떻게 변화되는지를 검토하였다.

  • PDF

DACUM 기법과 전문가회의를 통한 방재분야 교육과정 개발에 관한 연구 (A Study on Curriculum Development for Disaster Management by DACUM Technique and Expert Committee)

  • 민금영;정덕훈;심형섭
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.63-73
    • /
    • 2011
  • 본 연구는 방재분야의 교육과정 개발을 위해 DACUM 기법을 이용하여 개발한 교육과정과 전문가회의를 통해 개발한 교육 과정을 비교 분석하여 방재분야의 교육과정을 개발하였다. 첫째, DACUM 기법을 이용한 교육과정 개발은 방재분야의 직무를 예방, 대비, 대응, 복구 등 4가지 직무로 구분하고, 각 직무별로 3명의 방재전문가와 1명의 교육전문가가 3회씩의 워크삽을 통해 예방직무에서 9개 과정, 대비 직무에서 12개 과정, 대비 직무에서 7개 과정, 복구 직무에서 4개의 교육과정을 개발하였다. 둘째, 전문가회의를 통해 교육과정을 개발하였다. 전문가회의는 5명의 방재전문가와 3명의 교육전문가가 4회의 회의를 거쳐 35개의 교육과정을 개발하였다. 이를 통해 DACUM 기법과 전문가회의를 통해 도출된 교육과정을 전문가들의 토론을 거쳐 최종적으로 예방 및 대비 직무에서 31개 과정과 대응 및 복구 직무에서 14개의 교육과정을 개발하였으며, 추가적으로 인적재난에서 6개 과정과 관리자별 4개 과정을 개발하였다.

LIFO 방식을 이용한 실시간 트랜잭션 로그 회복 방안 (A Technique for Recovering Logs in Real-time Transactions by using a LIFO Method)

  • 박일태;최동열;오정훈
    • 융합보안논문지
    • /
    • 제3권3호
    • /
    • pp.51-57
    • /
    • 2003
  • 실시간 DBMS는 제한된 시간내에 사용자가 처리를 요청한 데이터를 가장 빠르고 안전하게 보관, 조작, 제어하는 기능을 제공해야 한다[3]. 이러한 실시간 제어 및 조작 기능을 담당하기 위하여, 실시간 DBMS 내에서 수행되는 트랜잭션에 대한 처리 과정의 상세 기록(로그)이 매우 중요하다. 본 논문에서는 이러한 기록을 기반으로 트랜잭션 로그에 대한 새로운 회복 기능을 제안한다. 본 회복 방안은 기본적으로 LIFO(Last-In-First-Out) 의 개념을 사용하였다. 제안하는 방법은 같은 속성을 가진, 연속적인 트랜잭션 로그를 효율적으로 기록, 처리 할 수 있는 방안이 될 것이다.

  • PDF