• Title/Summary/Keyword: Recording Methods

Search Result 555, Processing Time 0.034 seconds

Robustness of Bimodal Speech Recognition on Degradation of Lip Parameter Estimation Performance (음성인식에서 입술 파라미터 열화에 따른 견인성 연구)

  • Kim, Jin-Young;Min, So-Hee;Choi, Seung-Ho
    • Speech Sciences
    • /
    • v.10 no.2
    • /
    • pp.27-33
    • /
    • 2003
  • Bimodal speech recognition based on lip reading has been studied as a representative method of speech recognition under noisy environments. There are three integration methods of speech and lip modalities as like direct identification, separate identification and dominant recording. In this paper we evaluate the robustness of lip reading methods under the assumption that lip parameters are estimated with errors. We show that the dominant recording approach is more robust than other methods through lip reading experiments.

  • PDF

Dental radiology reporting status and recording frequency of reporting items in Korea

  • Jinwoo Choi
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.35-42
    • /
    • 2023
  • Purpose: This study investigated the current dental radiology reporting methods and the recording rate of 10 mandatory reporting items in Korea. Materials and Methods: An original online survey created using Google Forms was distributed to dental practitioners. The survey asked about the participants' age, experience, workplace, use of radiologic equipment, radiology reporting methods, and recording reporting items. Results: In total, 354 responses were analyzed. Radiologic reporting in dental charts was the most commonly used method for each modality. Four out of 10 mandatory items were recorded at a high rate, but the remaining 6 items had substantially lower recording rates, often below 50%. The participants who reported radiographic findings through other separate methods had higher item scores than those who wrote findings in dental charts(P<0.05). Conclusion: Radiologic societies and dental associations should encourage the use of separate reports for radiographic examinations. Education regarding radiology reports and the justification for reporting items should be reinforced in dental schools, training courses on radiology, and the continuing education curriculum.

Study of Laryngeal Evoked Electromyography Method in Rats (백서를 이용한 후두 유발 근전도 검사 방법에 대한 연구)

  • 조선희;이재연;민선식;신유리;정성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.2
    • /
    • pp.178-184
    • /
    • 2000
  • Laryngeal evoked EMG is the objective and quantitative method to measure the innervation of laryngeal muscle. If there is a mobility disorder of vocal cords, the cause and location of neural lesion co be understood by the laryngeal evoked EMG and if there is a vocal cord paralysis, the degree of recovery and the policy of treatment can be determined by it. Recently, the studies of reinnervation after recurrent laryngeal nerve injury have been actively carried out. Laryngeal evoked EMC is useful to these studies. The aim of study is to know whether noninvasive methods for stimulating the recurrent laryngeal nerve and for recording of compound action potential(CAP) using surface electrode are as useful as the invasive method using needle electrode. We obtained EMG of laryngeal muscle by various stimulating and recording methods : 1) Direct nerve stimulation by placing nerve cuff electrode made out of silastic tube and platinum wire and recording by insertion of hook wire electrode into posterior cricoarytenoid(PCA) and thyroarytenoid(TA) muscles, respectively. 2) Recording of compound action potential by surface electrode after stimulation of recurrent laryngeal nerve by the insertion of 27 gauge of needle electrode. 3) Recording of compound action potential by surface electrode after stimulating the recurrent laryngeal nerve by transcutaneous blunt rod electrode at tracheoesophageal groove. The amplitude, duration and latency of the CAP evoked by recurrent laryngeal nerve stimulation were compared among the three groups. The amplitude of CAP was smallest in the group recorded from posterior cricoarytenoid and hyroarytenoid muscle, and that recorded by surface electrode after stimulation by needle electrode was largest. The difference in amplitude between the group by hook wire recording and the two groups by surface electrode recording was significant statistically. There is no significant difference in duration and latency among three groups. Since the waveform of CAP from all three methods has similar duration, latency, we concluded that noninvasive method is a useful as invasive methods.

  • PDF

Random Sample Consensus (RANSAC)-based Automatic (game of) Go Recording System (Random Sample Consensus(RANSAC) 기반 자동 바둑 기보 시스템)

  • Park, D.J.;Jun, Kyungkoo
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.7
    • /
    • pp.829-837
    • /
    • 2014
  • This paper develops an automatic go recording system based on image processing. We use Random Sample Consensus to detect the circular shape of stone and propose a set of methods to improve the computational overhead of RANSAC. The proposed scheme is not affected by the changes of stone location, illumination, and camera distance, which is different from existing methods. We implemented the proposed scheme into a working system and confirmed that the recording is feasible and the problems have been improved.

Development and application of the intraoral tracer for the record of centric relation (중심위 채득을 위한 구내묘기장치의 개발과 응용)

  • Kwag, Heung Koo;Jeong, Soeg-Cho;Kang, Dong Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.37-49
    • /
    • 2000
  • It was clinically important to substitute the physiologic centric relation to the therapeutic position of the patients who needed the oral rehabilitation or occlusal treatment. There were several methods for recording the centric relation. One of the known methods was to use the gothic arch tracer. However the existing intraoral device was difficult to adjust the three dimensional angulation of the recording plate and recording stylus depending on the hinge movement arch of the individual. The purpose of this study was to develop new intraoral tracer which had adjustable stylus within hinge movement arch for the record of centric relation and to evaluate the clinical application of this device. The results were as follow; 1. A stylus of new developed intraoral tracer was so adjustable that the recording of mandibular positions could be reproducible within the hinge movement arc. 2. A record plate of new developed intraoral tracer was so adjustable to parallel with the occlusal plane that lateral recording of mandibular position was able to obtain stably. This study showed that new developed intraoral tracer allowed the determination of the treatment position which can be used in the full mouth rehabilitation and occlusal treatments.

  • PDF

A Study of the Long Wave Track Defect Analysis for High Speed Railway (고속철도의 장파장 제도틀림 분석에 대한 연구)

  • Kang Kee-Dong
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The Study provides the technical background and calculation method f3r the long wave track defect. On high speed railway, It is necessary to manage the long wave band up to 80m track defect fur improving a riding quality. For this reason, Track recording methods for highspeed railway are used 10m and 30m recording bases, these are covered middle wave band and long wave band successfully. Extended base recording data is calculated by geometrical model and this data provides a good result for KTX riding index.

Indirect PIN Entry Method for Mobile Banking Using Relative Location Information of Secret Code (비밀코드의 상대적 위치정보를 이용한 모바일 뱅킹용 간접 PIN 입력 기법)

  • Choi, Dongmin
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.6
    • /
    • pp.738-746
    • /
    • 2020
  • In this paper, we propose an indirect PIN entry method that provides enhanced security against smudge, recording, and thermal attacks. Conventional mobile PIN entry methods use on-screen numeric keypad for both use of display and entry. Thus These methods are vulnerable to aforementioned attacks. In our method, passcode is same as that of the conventional PIN entry methods, and that is user-friendly way for mobile device users. Therefore, our method does not reduce user convenience which is one of the advantages of the conventional methods. In addition, our method is not a method of directly touching the on-screen numeric keypad for entering passcode like the conventional PIN methods. Unlike the conventional methods, our method uses an indirect passcode entry method that applied a passcode indicating key. According to the performance comparison result, proposed method provides user convenience similar to the conventional methods, and also provides a higher level of security and safety against recording, smudge, and thermal attacks than the conventional methods.

A review on several methods for fast generation of digital Fresnel holograms

  • Tsang, P.W.M.
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.2
    • /
    • pp.29-32
    • /
    • 2012
  • Computer generated holography (CGH) is technology for generating holograms of synthetic, three dimensional (3D) objects which may not exist in the physical world. The process, however, requires heavy amount of computation as the resolution of a hologram is significantly higher than that of a typical optical image. This paper reviews four modern techniques for fast generation of digital Fresnel holograms which are important in the development of holographic video systems. The methods that will be described include the virtual window, sub-line, wavefront recording plane (WRP), and the interpolative WRP schemes. These works share the common objective to generate digital Fresnel hologram at a speed that is close to the video frame rate, and with complexity which is realizable with affordable computing and reconfigurable hardware devices. The author will present the principles and realization of these works, as well as some potential area of research in digital holography.

The Recording Time Schedule in the Phase-Code Multiplexing System (위상부호 홀로그램 중첩 시스템에서 홀로그램의 중첩저장 및 복원을 위한 기록시간 분배)

  • 김유현;손승대;이연호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.2
    • /
    • pp.88-97
    • /
    • 2003
  • Computer simulations of the recording and reading of holograms in an 8-bit phase-code multiplexing system are presented. From the computer simulation each recording time of eight holograms is obtained such that the strength of restored holograms is same. An analytic formula to predict the recording times is derived by fitting the formula to the computer simulation data. It is found that our analytic formula can predict the hologram recording time not only in 8-bit system but also in 16-bit and 32-bit systems in an error less than $\pm$8.4%. Optical experiments are also performed in a 4-bit phase code-multiplexing system. It is found that the strength of the restored holograms is more uniform compared with conventional methods.

Laryngeal Evoked Electromyography with a Noninvasive Technique (비침습적 방법에 의한 후두유발근전도 검사)

  • 정성민;조선희;박기덕
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 1999
  • Background and Objectives : Laryngeal Evoked Electromyography(EEMG) is a objective, quantitative technique to determine innervation status of larynx. The possible applications of this technique are to confirm the etiology of impaired vocal fold motion and monitor perioperative vagus nerve trauma. The purpose of this study is to develop a novel method for determining the amount of reinnervation of recurrent laryngeal nerve with accurate, inexpensive, and minimally invasive technique in human. Materials and Methods : Laryngeal EEMG was performed for 16 adults with intact vocal folds motion and 2 patients diagnosed as unilateral vocal fold paralysis. for the purpose of searching what is the optimal and noninvasive technique for laryngeal EEMG, we used 2 types of stimulation configurations(transcutaneous vs percutaneous) and 2 types of recording configurations(intramuscular vs. surface). Results and Conclusions : Percutaneous needle stimulation and surface recording of laryngeal EEMG was reliable and comparable to standard needle stimulation and invasive intramuscular needle recording. But the laryngeal EEMG by the surface recording and transcutaneous surface stimulation was not reliable and repeatable. Therefore we recommended that laryngeal EEMG by surface recording and percutaneous needle stimulation would be minimally invasive, reliable technique to know the status of reinnervation in e patients with vocal fold paralysis.

  • PDF