• 제목/요약/키워드: Reconstruction plate

검색결과 187건 처리시간 0.024초

Comparison of Mechanical Stability between Fibular Free Flap Reconstruction versus Locking Mandibular Reconstruction Plate Fixation

  • Chung, Jae-Hyun;Yoon, Eul-Sik;Park, Seung-Ha;Lee, Byung-Il;Kim, Hyon-Surk;You, Hi-Jin
    • 대한두개안면성형외과학회지
    • /
    • 제15권2호
    • /
    • pp.75-81
    • /
    • 2014
  • Background: The fibular free flap has been used as the standard methods of segmental mandibular reconstruction. The objective of mandibular reconstruction not only includes restored continuity of the mandible but also the recovery of optimal function. This paper emphasizes the advantage of the fibular free flap reconstruction over that of locking mandibular reconstruction plate fixation. Methods: The hospital charts of all patients (n=20) who had a mandibular reconstruction between 1994 and 2013 were retrospectively reviewed. Eight patients had plateonly fixation of the mandible, and the remaining 12 had vascularized fibular free flap reconstruction. Complications and outcomes were reviewed and compared between the 2 groups via statistical analysis. Results: Overall complication rates were significantly lower in the fibular flap group (8.3%) than in the plate fixation group (87.5%; p =0.001). Most (7/8) patients in the plate fixation group had experienced plate-related late complications, including plate fracture or exposure. In the fibular flap group, no complications were observed, except for a single case of donor-site wound dehiscence (1/12). Conclusion: The fibular free flap provides a more stable support and additional soft tissue support for the plate, thereby minimizing the risk of plate-related complications. Fibular free flap is the most reliable option for mandibular reconstruction, and we believe that the flap should be performed primarily whenever possible.

Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support

  • Song, In-Seok;Ryu, Jae-Jun;Choi, Young-Jun;Lee, Ui-Lyong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권3호
    • /
    • pp.233-236
    • /
    • 2021
  • A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

하악골 절제술후 간단한 과두재위치 소형금속판을 이용한 재건 금속판의 적용: 증례보고 (APPLICATION OF RECONSTRUCTION PLATE USING SIMPLE CONDYLAR REPOSITIONING MINIPLATE AFTER SEGMENTAL RESECTION OF MANDIBLE)

  • 김영균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권3호
    • /
    • pp.231-233
    • /
    • 2002
  • Temporary reconstruction of the mandibular continuity defect resulting from the ablative tumor surgery with a reconstruction plate can be used for the preservation of normal facial contour and oral function and for periodic follow up of recurrence. Reconstruction plates are adapted to the bone before the resection and provisionally fixated with some screws. Accurate contouring and adaptation are very important for the prevention of displacement of bony stumps and decubituous skin ulcer. However, if there is large expanding buccal tumor mass in mandible, it is very difficult or even impossible to contour the plate before resection. I, therefore, introduce the reconstruction plate application technique using a simple condylar repositioning miniplate after segmental mandibular resection.

유한 요소법을 이용한 하악골 이부 결손수복에 사용된 재건용 금속판의 응력분포에 관한 연구 (FINITE ELEMENT ANALYSIS OF RECONSTRUCTION OF MANDIBULAR SYMPHYSIS DEFECTS USING RECONSTRUCTION PLATES)

  • 오정환;한정수;민지현;문성준;이백수
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권6호
    • /
    • pp.513-517
    • /
    • 2008
  • Purpose: This study aimed to evaluate distribution and maximal value of mechanical stresses on the reconstruction plate, bridging mandibular symphysis defect, and to optimize the most appropriate locations of the plate to distribute the stress causing the fracture of the plate. Materials and methods: Four types of reconstruction were constructed by different number and location of the reconstruction plates on the 3 D finite element model (FEM) of a human edentulous mandible; Type I: one plate on the inferior border of the anterior mandible, Type II: one plate on the middle of the anterior mandible, Type III: one plate on the superior border of the anterior mandible, and Type IV: two plates on the inferior and superior border of the anterior mandible. Results: The results showed that the maximal stress of type I (234.29 Mpa) was lower than that of type II (260.91 Mpa) and type III (247.37 Mpa), but higher than that of type IV (186.64 Mpa). We could also observe that the stresses are tending to focus on the inner side and inferior part of the plate which connected proximal segment from the vertical load. Conclusions: On the basis of the findings, it was concluded that using a plate on the inferior border of mandible or two plates on the inferior and superior border of mandible are more favorable to distribute mechanical stresses, which could reduce the fracture of the plate.

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • 제4권1호
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.

플레이트의 소성변형 과정이 재건술에서 플레이트 안정성에 미치는 영향 (On the Stability of the Permanently Bent Mini-plate in Reconstructive Surgery)

  • 박시명;이득희;노건우
    • 한국CDE학회논문집
    • /
    • 제21권3호
    • /
    • pp.234-241
    • /
    • 2016
  • Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic deformation during the bending process. In this study we investigate stability of the plastically deformed plate and the plate with the same shape without plastic deformation through the finite element analysis(FEA). First we simulate the process of plate bending to fit the defect in patient. Then, the other plate is modelled to represent a customized plate with the same shape of the plastically deformed one, but without any residual stresses from plastic deformation. After binding these plates to the mandible, we conduct the masticatory simulation. Finally, we compare the resulting Von Mises stress of the customized plate and of the bent plate. The bent plate shows much higher stress than the customized one due to the residual stresses form the bending process. The study shows that plastic deformation in the plate may decrease the safety of the reconstruction surgery.

Quantitative Analysis of Bayesian SPECT Reconstruction : Effects of Using Higher-Order Gibbs Priors

  • S. J. Lee
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.133-142
    • /
    • 1998
  • Bayesian SPECT 영상재구성에 있어서 정교한 형태의 사전정보를 사용할 경우 bias 및 variance와 같은 통계적 차원에서의 정량적 성능을 향상시킬 수 있다. 특히, "thin plate" 와 같은 고차의 smoothing 사전정보는 "membrane"과 같은 일반적인 다른 사전 정보에 비해 bias를 개선시키는 것으로 알려져 있다. 그러나, 이와 같은 장점은 영상재구성 알고리즘에 내재하는 hyperparameters의 값을 최적으로 선택하였을 경우에만 적용된다. 본 연구에서는 thin plate와 membrane의 두가지 대표적인 사전정보를 포함하는 영상재구성 알고리즘의 정량적 성능에 대해 집중 고찰한다. 즉, 알고리즘에 내재하는 hyperparameters 가 통계적 차원에서 bias와 variance에 어떠한 영향을 미치는지 관찰한다. 실험에서 Monte Carlo noise trials를 사용하여 bias와 variance를 계산하며, 각 결과를 ML-EM 및 filtered backprojection으로부터 얻어진 bias 및 variance와 비교한다. 결론적으로 thin plate와 같은 고차의 사전정보는 hyperparameters의 선택에 민감하지 않으며, hyperparameters 값의 전 범위에 걸쳐 bias를 개선시킴을 보인다. 걸쳐 bias를 개선시킴을 보인다.

  • PDF

재건용금속판을 따라 하악골편 전이 골신장기를 이용한 하악골 연속성의 회복 (RESTORATION OF MANDIBULAR CONTINUITY USING MANDIBULAR TRANSPORT DISTRACTOR GUIDED BY RECONSTRUCTION PLATE)

  • 김성민;정지훈;김한석;김지혁;박영욱;이종호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권5호
    • /
    • pp.429-438
    • /
    • 2007
  • Transport distraction osteogenesis has been introduced recently to correct skeletal malformations and discrepancies in the maxillofacial area. To reconstruct 3-dimensitonal mandibular shape, this transport distraction can be considered with the use of reconstruction plate. A 23-years-old male having unilateral mandibular body and angle defects, who had been operated of partial mandibular resection due to unicystic ameloblastoma, was treated by transport distraction procedures with ThreadLock transport $distractor^{(R)}$ (KLS Martin Co., Germany) through the rail of reconstruction plate (Osteomed Co., USA). After being distracted 35 mm defect from mandibular angle to body, and consolidated for 16 weeks, allogenic bone graft on docking site was performed with removal of transgingival pin. For more than 13 weeks follow up period after consolidation period, gradual increase of radiopacity in the radiographic examination was shown, and the curved mandibular continuity according to the reconstruction plate was made firmly. These transport distraction osteogenesis in the mandible was able to be considered as the good and minimally invasive technique for the reconstruction of mandibular discontinuity. Young patient was also very satisfactory for these results.

Reconstruction of Large Femur and Tibia Defect with Free Vascularized Fibula Graft and Locking Plate

  • Kim, Min Bom;Lee, Young Ho;Baek, Jeong Kook;Choi, Ho Sung;Baek, Goo Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • 제24권2호
    • /
    • pp.68-74
    • /
    • 2015
  • Purpose: The reconstruction of femur and tibia defects following tumor resection remains a surgical challenge. The clinical outcome of free vascularized fibula graft (VFG) reconstruction with locking plate for massive femur and tibia defects of more than 10 cm that were secondary to skeletal tumor resection is reported. Materials and Methods: Thirteen patients with a mean follow-up of 3.3 years were reviewed. Seven patients received vascularized fibula grafts in the femur and six in the tibia. The mean bony defect of the femur and tibia was more than 10 cm and the length of the grafted fibula was more than 15 cm. All defects were stabilized with long locking plates. Results: All patients were free of disease at final follow-up; All VFGs were transferred successfully. All patients had a successful outcome with bony union. Stress fractures of the grafted fibula had occurred but the locking plate stabilized the fracture and healed until the last follow-up. All patients were able to walk without a brace after a mean of 9 months postoperatively. Conclusion: VFG with locking plate is a reliable reconstructive procedure for massive femur and tibia defects.

Myeloma로 인한 흉골절제와 Tantalum 의 흉골재건술 (1례 보고) (Total Sternal Resection and Reconstruction Using Tantalum Plate)

  • 김근호
    • Journal of Chest Surgery
    • /
    • 제7권1호
    • /
    • pp.67-72
    • /
    • 1974
  • This is a case report of total sternal resection and successful reconstruction of the sternum applying Tantalum plate in multiple myeloma. The patient was a 57 year old male with a tumor located on the middle sternum invading the manubrium and the body of the sternum developing symptoms after a contusion of the anterior sternum. The sternum resected with left and right. from first to sixth costochondral cartilages, and then Tantalum plate was fixed to the all fragments of the ribs with wire sutures. After reconstruction of the sternum applying Tantalum plate, the patient has had good breathing movements of the chest wall and also maintenance of respiratory function was satisfactory. Histopathologically, the tumor was consisted of a tissue of plasma cells, which was identical to multiple myeloma. Postoperative chemotherapy with Endoxan for multiple myeloma was administered. No recurrent symptoms of multiple myeloma could be observed during one year follow up period.

  • PDF