• Title/Summary/Keyword: Reconstructed image

Search Result 1,145, Processing Time 0.02 seconds

The Characteristics of Traditional Representation in the Artist's Garden of the Garden Exposition seen through the Design Process (설계과정을 통해 본 정원박람회 작가정원의 전통재현 특성)

  • Lee, Song-Min;So, Hyun-Su
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.38 no.4
    • /
    • pp.101-110
    • /
    • 2020
  • This study was conducted through the analysis of literature and on-site research as a case study of 14 artists' gardens with traditional themes presented at the garden fair. With Focusing on the design process for determining traditional reproduction, the following characteristics and implications were derived by analyzing the design goals, selection of subjects for traditional reenactment, determination of methods for reproduction, and design stages of landscape components. First, the pattern of selecting traditional structures as subjects for reproduction in many artist gardens can be understood as an advantage of being suitable for narrow sites and having remarkable topic communicability. They directly delivered the design intent by adding the names of traditional structures such as Madang, Wool, Buttumak, Jangdokdae, Chuibyeong and Seokgasan. Works expressed indirectly, such as Wall, Korean Garden, Suwon, and Seoul craftsmen, have relatively weak topic communicability. There were also symbolic representations of objects to be reproduced, such as Seonbi, marginal spaces, and Pung-lyu. Second, while reproducing Hanok Madang, separate the gardens paved with grass and stone, the fortress wall of Suwon Hwaseong and the northwest Gongsimdon of the watchtower. Also the garden with a miniature version of the extraneous Yong-yeon and the garden, which was reproduced as a low decorative wall in the rest area based on Nakan-Eupseong Fortress, shows the need for a deep understanding of tradition. On the other hand, the reproducting works of choosing the location of the traditional garden, the Korean Garden showed the importance of systematic arrangement with the surrounding environment, the beauty of the space in the courtyard of Hanok, the beauty of the slowness enjoyed by the scholars and the reenactments of the Pung-lyu culture of Moonlight boating are not only imitating traditional structures but also spreading understanding of tradition to garden culture and sentiment. Third, there were many works that reconstructed the real-size traditional structure in a straightforward way in relation to design. The garden was divided into Chuibyeong and the living space was decorated with Buttumak, chimneys, and gardens, and facilities representing Gyeongbokgung Palace, Soswaewon, and Seoseokji were systemically arranged. However it recognized the importance of selecting the key design elements, constructing the elevation of the structure, and the sense of scale of the space from works that reproduced the large Suwon Hwaseong and Nakan-Eupseong in an abstract way. While there are examples gardens of Hanok yards and Bazawul, which are far from the original image among the gardens that chose the dismantling method, the Blank-space garden expressed only by a frame composed of cubes, and Seonbi's Sarangbang garden, that permeated the moonlight with many traditional structures are the positive examples. The Seoul Artisan Garden, Jikji Simche Garden and Pung-lyu Garden, which display modernly designed landscape components, need an explanation to understand the author's intention.

Jeonghyesa Temple reconstructed at Yesan by Mangong and the meaning of the creation of the stone standing Avalokiteśvara statue during the Japanese colonial period (일제강점기 만공(滿空)의 예산 정혜사 중창과 석조관음보살입상 조성의 의미)

  • Lee Jumin
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.22-43
    • /
    • 2023
  • This paper deals with the stone standing Avalokitesvara statue in Jeonghyesa Temple that was created by Mangong in 1924. The stone standing Avalokitesvara statue of Jeonghyesa Temple is the earliest extant Buddha statue produced by Mangong, and symbolism was given to Jeonghyesa in the process of its reconstruction. So far, there has been no study that has approached ideas and beliefs through Buddhist studies led by Mangong and specific relics. In order to proceed with this study, Mangong's legal words and anecdotes and newspaper articles during the Japanese colonial era were used to trace the dynamics of Jeonghyesa and Sudeoksa during Mangong's reign, and to investigate the effects obtained from the creation of the large Bodhisattva statue and the meaning of its location. In addition, an interview was attempted with the descendants of master, who were in charge of the sculpture at the time, to confirm the exact construction period and the list of craftsmen. It is judged that the stone standing Bodhisattva statue of Gwanchoksa Temple has been influenced by the double covering and square crown seen in the standing stone statue of Avalokitesvara Bodhisattva of Jeonghyesa Temple, the large hands compared to the body, the proportion between the head and the body, and the sense of enormity felt in the body like a stone pillar. Therefore, we looked at how the standing stone Bodhisattva statue of Gwanchoksa Temple, which was produced in the early Goryeo Dynasty, could have influenced the creation of the Bodhisattva statue in the modern period. A multilateral analysis was attempted on how the image of the Gwanchoksa Bodhisattva statue, which was used as a symbol representing Chungcheongnam-do in the Chosun Exposition held in 1929 and the visit to Gwanchoksa Temple, which began with the laying of the railroad during the Japanese colonial period, was used from the viewpoint of the succession and transformation of the style. With this study as an opportunity, it is hoped that the understanding of the prehistoric Mangong representing the modern period and the horizon of Korean Buddhist sculpture research in the modern period will be broadened.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.

  • PDF

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.