• Title/Summary/Keyword: Recirculating

Search Result 404, Processing Time 0.023 seconds

A Study on the Drag and Heat Transfer Reduction Phenomena and Degradation Effects of the Viscoelastic Fluids (점탄성유체의 저항 및 열전달 감소현상과 퇴화의 영향에 관한 연구)

  • Eum, C.S.;Jeon, C.Y.;Yoo, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.1
    • /
    • pp.37-48
    • /
    • 1990
  • The drag and heat transfer reduction phenomena and degradation effects of drag reducing polymer solutions which are known as the viscoelastic fluids are investigated experimentally for the turbulent circular tube flows. Two stainless steel tubes are used for the experimental flow loops. Aqueous solutions of Polyacrylamide Separan AP-273 with concentrations from 300 to 1000 wppm are used as working fluids. Flow loops are set up to measure the friction factors and heat transfer coefficients of test tubes in the once-through system and the recirculating flow system. Test tubes are heated by power supply directly to apply constant heat flux boundary conditions on the wall. Capillary tube viscometer and falling ball viscometer are used to measure the viscous characteristics of fluids and the characteristic relaxation time of a fluid is determined by the Powell-Eyring model. The order of magnidude of the thermal entrance length of a drag reducing polymer solution is close to the order of magnitude of the laminar entrance length of Newtonian fluids. Dimensionless heat transfer coefficients of the viscoelastic non-Newtonian fluids may be represented as a function of flow behavior index n and newly defined viscoelastic Graetz number. As degradation continues viscosity and the characteristic relaxation time of the testing fluids decrease and heat transfer coefficients increase. The characteristic relaxation time is used to define the Weissenberg number and variations of friction factors and heat transfer coefficients due to degradation are presented in terms of the Weissenberg number.

  • PDF

Numerical Study of Turbulent Flow and Combustion in a Micro Combustor with a Baffle Plate (배플이 부착된 마이크로 연소기의 난류유동 및 연소에 대한 수치해석 연구)

  • Kim, Won Hyun;Park, Tae Seon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.20-29
    • /
    • 2013
  • Turbulent flow and combustion characteristics in a micro can combustor with a baffle plate are investigated by a Reynolds Stress Model. In order to examine the geometric effects on the turbulent combusting flow, several baffle configurations are selected. The interrelation between the flow structure and the thermal field are investigated by examing the variation of recirculation region, flame length and heat loss. For the flow mixing, the decreasing air hole is more efficient than the decrease of the fuel hole. As the fuel or air hole diameter decreases, combustion efficiency is enhanced and flame length is decreased. Additionally, as the diameter of air hole decreases, the heat loss and combustion temperature are increased, while they are reduced with decreasing the diameter of fuel hole.

An experimental study on the open channel flow with plane wall jet inlet boundary condition and effects of a baffle (평면벽면분류의 유입경계조건을 가지는 개수로 유동 및 배플의 영향에 관한 실험적 연구)

  • 방병렬;설광원;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1399-1406
    • /
    • 1988
  • Flow behaviors of the open channel type flow with its geometric boundary conditions being similar to that of the Multi-Stage-Flash evaporator were studied qualitatively by measuring the velocity distribution. Without a baffle, the flow was in the shape of a simple submerged plane wall jet. At the downstream of this flow, the jet boundary made sharp curve toward the free surface ; this is because the entrainment of the ambient liquid is restricted by the free surface boundary, similar to the Coanda effect. According to the experimental results the level of the free surface appeared to be the most important parameter. The flow with a baffle was in much complicated shape ; especially the recirculating region at the downstream free surface was detected according to the experimental conditions imposed. Inlet liquid velocity, heights of the liquid level and the baffle, and the opening heights of sluice gate of the entrance were the most important parameters in the baffle flow.

Isobaric Vapor-Liquid Equilibrium of 1-propanol and Benzene System at Subatmospheric Pressures (일정압력하에서 1-propanol/benzene 계의 기-액 상평형)

  • Rho, Seon-Gyun;Kang, Choon-Hyoung
    • Korean Chemical Engineering Research
    • /
    • v.56 no.2
    • /
    • pp.222-228
    • /
    • 2018
  • Benzene is one of the most widely used basic materials in the petrochemical industry. Generally, benzene exists as a mixture with alcohols rather than as a pure substance. Further, the alcohols-added mixtures usually exhibit an azeotropic composition. In this context, knowledge of the phase equilibrium behavior of the mixture is essential for its separation and purification. In this study, the vapor-liquid equilibrium data were measured in favor of a recirculating VLE apparatus under constant pressure for the 1 - propanol / benzene system. The measured vapor - liquid equilibrium data were also correlated by using the UNIQUAC and WILSON models and the thermodynamic consistency test based on the Gibbs/Duhem equation was followed. The results of the phase equilibrium experiment revealed RMSEs (Root Mean Square Error) and AADs (Average Absolute Deviation) of less than 0.05 for both models, indicating a good agreement between the experimental value and the calculated value. The results of the thermodynamic consistency test also confirmed through the residual term within ${\pm}0.2$.

Performance Analysis of Time Division Multiplexed Optical Output Buffers (시간 분할 다중합 광 출력 버퍼의 성능 분석)

  • 정준영;고광철;정제명
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.9B
    • /
    • pp.751-759
    • /
    • 2003
  • We analyze the performances, such as the cell loss probability(CLR) and the cell delay time, of time division multiplexed(TDM) optical output buffers using traveling delay lines or delay-line loops for buffering. Since traveling delay lines used for buffering are superior over delay-line loops in terms of simplicity and signal quality, they were used in a conventional TDM optical output buffer. However, the latter is more flexible than the former in that the cell storage time is adjustable by changing the recirculating times of a cell in the loops. So we propose a novel TDM optical output buffer using delay-line loops for buffering. We show that the proposed TDM optical output buffer can reduce the number of buffering unit required to achieve a CLR of less than 10$^{-9}$ . When the number of buffering unit is sufficiently large, we show that both TDM optical output buffers have same cell delay time characteristic.

Absorption of Itraconazole from Rat Small Intestine (이트라코나졸의 랫트 소장으로부터의 흡수)

  • Kim, Young-Hwa;Lee, Yong-Suk;Park, Gee-Bae;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.4
    • /
    • pp.215-222
    • /
    • 1991
  • The absorption characteristics of itraconazole, which is an antifungal agent, from intestinal segments in the anesthetized rat i1l situ were investigated in order to design an effective oral drug delivery system. The pH-solubility profile of itraconazole, the rate and extent of absorption of itraconazole, the optimal absorption site(s) of itraconazole and the absorption enhancing effect of sodium cholate on itraconazole were examined in the present study. In situ single-pass perfusion method and recirculating perfusion technique using duodenum(D), jejunum(J) and ileum(I) were employed for the calculation of apparent permeability(Pe) and apparent first-order rate constant(Kobs). respectively. The results of this study were as follows; (1) Itraconazole showed appreciable aqueous solubility only at pH values of below 2.0. (2) pe(cm/sec) decreased in the following order: $D(10.24{\pm}1.78{\times}10^{-4})>J(8.86{\pm}0.79{\times}10^{-4})>I(3.78{\pm}0.13 X 10^{-4})$. (3) $Kobs(min^{-1})$ decreased in the following order: $J(17.12{\pm}3.19{\times}10^{-3})>D(13.37{\pm}0.6{\times}10^{-3})>I(11.05{\pm}0.91{\times}10^{-3})$. (4) The solubility of itraconazole markedly increased with the increase of the concentration of sodium cholate. (5) The addition of 10 mM sodium cholate significantly increased the apparent first-order rate constant of itraconazole in the ileum by a factor of 6.8.

  • PDF

Comparative Evaluation of Determination Methods of Vertical Eddy Viscosity for Computation of Wind-Induced Flows (풍성류 계산을 위한 연직 와점성계수 산정방법의 비교평가)

  • 정태성;이길성;오병철
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.6 no.3
    • /
    • pp.205-215
    • /
    • 1994
  • A 3-dimensional numerical model of wind-induced flows has been established. and comparative evaluation of determination methods of vertical eddy viscosity has been performed. The model uses turbulence models to calculate vertical eddy viscosity. The examined methods arp 0-equation model of functional form, 1-equation model of turbulence kinetic energy, and two 2-equation models ($textsc{k}$-$\varepsilon$ and $textsc{k}$-ι models). The evaluation includes the verification tests against experimental data for wind-driven current On a closed one-dimensional channel and a recirculating one-dimensional channel. Comparative study of turbulence models has shown that the proper distribution of turbulence scale is parabolic and the eddy viscosity is depending strongly on mixing depth due to wind.

  • PDF

Detached Eddy Simulation of Base Flow in Supersonic Mainstream (초음속 유동에서 기저유동의 Detached Eddy Simulation)

  • Shin, Jae-Ryul;Moon, Sung-Young;Won, Su-Hee;Choi, Jeong-Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.955-966
    • /
    • 2009
  • DES method is applied to an axisymmetric base flow at supersonic mainstream. The model is based on the Spalart-Allmaras (S-A) turbulence model in the RANS mode, and is based on the subgrid scale model in the Large-eddy simulation (LES) mode. Accurate predictions of the base flowfield and base pressure are successfully achieved by using the DES methodology which is less expensive than LES. Flow properties at the edge of base, such as boundary layer thickness, momentum thickness and skin fraction are compared with Dutton et al [experimental data to proper prediction of base flowfiled. From the present results, The DES accurately resolves the physics of unsteady turbulent motions, such as shear layer rollup, large-eddy motions in the downstream region and small eddy motions inside the recirculating region. Moreover, The present results of using an empirical constant $C_{DES}$ of 1.2 shows good agreement with experimental data than conventional empirical constant $C_{DES}$ of 0.65.

An experimental study on the thermal entrance lengths for viscoelastic polymer solutions in turbulent tube flow (점탄성 특성을 가진 폴리머용액의 난류유동 열적입구길이에 관한 실험적 연구)

  • 유상신;황태성;엄정섭
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1189-1196
    • /
    • 1988
  • Thermal entrance lengths of turbulent tube flow for viscoelastic polymer solutions are investigated experimentally in the recirculating flow system with tubes of inside diameters 8.5mm(L/D=710) and 10.3mm(L/D=1158), respectively. In the present system, the hydrodynamic and thermal boundary layers develop simultaneously from the beginning of the test section. To provide the boundary condition of constant heat flux at the wall, the test tubes are heated directly by electricity. The polymer solution used in the current study is 1000 wppm aqueous solution of polyacrylamide(Separan AP-273). The apparent viscosity of the polymer solutions circulating in the flow system are measured by the capillary tube viscometer at regular time intervals. Thermal entrance lengths vary due to the rate of degradation. The entrance lengths of degraded polymer solutions are about 500~600 times the diameter. However, the entrance lengths of fresh polymer solutions are greater than the lengths of the test tubes used in this study suggesting that thermal entrance lengths for viscoelastic polymer solutions are greater than 1100 tube times the diameters. Friction factor is almost insensitive to the degradation, but the heat transfer $j_{H}$-factor is affected seriously by degradation. Based on the present experimental data of fresh solutions a correlation for the heat transfer $j_{H}$-factor is presented.ted.

Decomposition of Ethylene by Using Dielectric Barrier Discharge Plasma (유전체 배리어 방전 플라즈마를 이용한 에틸렌의 분해)

  • Jang, Doo Il;Lim, Tae Hun;Lee, Sang Baek;Mok, Young Sun;Park, Hoeman
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.608-613
    • /
    • 2012
  • Dielectric barrier discharge plasma reactor was applied to the removal of ethylene from a simulated storage facility ($1.0m^3$) of fruits and vegetables. The system operated in a closed-loop mode by feeding the contaminated gas to the plasma reactor and recirculating the treated gas back to the storage facility. The experiments were carried out with parameters such as discharge power, circulation flow rate, initial ethylene concentration and treatment time. The rate of ethylene decomposition was mainly controlled by the discharge power and the treatment time. With the other conditions kept constant, the ethylene decomposition rate in the presence of the manganese oxide ozone control catalyst installed downstream from the plasma reactor was lower than that in the absence of it. The suggests that unreacted ozone from the plasma reactor accumulated in the storage facility where it additionally decomposed ethylene. On the basis of an initial ethylene concentration of 50 ppm, the energy requirement for completing the decomposition was about 60 kJ.