• Title/Summary/Keyword: Recirculating

Search Result 403, Processing Time 0.031 seconds

Culture of Nile Tilapia (Oreochromis niloticus) in Recirculating Aquaculture System (순환여과식 양식 시스템에서 나일 틸라피아(Oreochromis niloticus)의 사육)

  • Seo Kuen Hack;Kim Byong Jin;Jo Jae Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.1
    • /
    • pp.27-34
    • /
    • 2002
  • The performances of fish culture were evaluated in the integrated recirculating aquaculture system consisting of a double drain type rearing tank ($2.5 m^3$), a sedimentation tank, a floating bead filter, a foam separator and a rotating biological contactor. A system was stocked with nile tilapia at an initial rearing densities of $5\%$ (A), $5\%$ (B) and $7\%$ (C) oyer 30 days. Feed coefficient was 1.62, 1,79 and 1.80 and average daily growth rate was $0.452\%$, 0.u5% and $0.423\%$, respectively. The level of TAN was maintained below $1 g/m^3$ for $5\%$ of initial rearing density and $2-4 g/m^3$ for $7\%$. The dissolved oxygen level ($2-4 g/m^3$) was not optimum but should not be inhibitory to fish growth. The total suspended solid was completely removed during overall experimental period.

Fluidelastic Instability Analysis of the U-Tube Bundle of a Recirculating Type Steam Generator (재순환식 증기발생기 U-튜브군에 대한 유체탄성 불안정 해석)

  • 조종철;이상균;김웅식;신원기;은영수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.200-214
    • /
    • 1993
  • This paper presents the results of fluidelastic instability analysis performed for the U-tube bundle of a Westinghouse model 51 steam generator, one of the recirculating types designed at an early stage, in which the principal region of external cross-flow is associated with the U-bend portion of tube. The prerequisites for this analysis are detailed informations of the secondary side flow conditions in the steam generator and the free vibration behaviours of the U-tubes. In this study, the three-dimensional two-phase flow field in the steam generator has been calculated employing the ATHOS3 steam generator two-phase flow code and the ANSYS engineering analysis code has been used to calculate the free vibration responses of specific U tubes under consideration. The assessment of the potential instability for the suspect U-tubes, which is the final analysis process of the present work, has been accomplished by combining the secondary side velocity and density distributions obtained from the ATHOS3 prediction with the relative modal displacement and natural frequency data calculated using the ANSYS code. The damping of tubes in two-phase flow has been deduced from the existing experimental data by taking into account the secondary side void fraction effect. In operation of the steam generator, the tube support conditions at the tube-to-tube support plate intersections due to either tube denting degradation or deposition of tube support plate corrosion products or ingression of dregs. Thus, various hypothetical cases regarding the tube support conditions at the tube-to-tube support plate intersections have been considered to investigate the clamped support effects on the forced vibration response of the tube. Also, the effect of anti-vibration bars support in the curved portion of tube has been examined.

Effect of Various Dietary Protein Levels on Growth and Body Composition of Young Common Carp Reared in Recirculating System

  • Cho, Sung-Hwoan;Jo, Jae-Yoon;Hur, Sung-Bum;Kim, You-Hee;Shin, Chang-Hoon
    • Journal of Aquaculture
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • The effect of various dietary protein levels on growth and body composition of young common carp raised from 56 g to 170 g in recirculating system was investigated for 15 weeks when they were fed to visual satiety three times daily. Five experiemtal diets were formulated to contain 40, 35, 30, 25 and 21% protein levels and 3.56, 3.59. 3.63, 3.66 and 3.69 kcal/g diet GE levels respectively. Mean survival rates of the fish fed the 40, 35, 30 and 25% protein diets were not different but sig-nificantly higher than that of the fish fed the 40, 35, 30 and 25% protein diets were not different but sig-nificantly higher than that of o the fish fed the 21% protein diet(P<0.05) Weight gain (g/tank) of common carp fed the 30% protein diet was the best. However weight gain of the fish fed the 25, 30, 35 and 40% protein diets were not different but significantly better than that of the fish fed the 21% protein diet. Feed efficiency ratio of the 21% protein diet was significantly lower (P<0.05) than for other groups of diets which were not different among them. Protein efficiency ratio for the 21% protein diet was significantly lower (P<0.05) than for other groups of diets which were not different among them(P>0.05) Dietary protein level had no effect on hemoglobin content in the fish(P>0.05) Crude protein contents of whole body of the fish fed the 35 and 40% protein diets were significantly higher than that of the fish fed the 21$$\mid$% or 25% protein diet(P<0.05) Body crude lipid contents of the fish fed the 21 and 25% protein diets were significantly higher than that of the fish fed the 30% or 35% protein diet. Crude ash contents of the fish fed the 35 and 40% protein diets were significantly higher than that of the fish fed the 21% or 25% protein diet(P<0.05) Moisture content of the fish fed the 35% protein diet was significantly higher than that of the fish fed the 21% protein diet(P<0.05) In considering growth performance of common carp and efficiency of diet dietary protein level could be lowered up to 25% without the reduction of young common carp production in recirculating system.

  • PDF

Optimum stocking density of juvenile abalone, Haliotis discus hannai in recirculating culture system (순환여과 사육시스템에서 참전복의 적정 사육밀도)

  • 손맹현;조기채;김경길;전임기
    • Journal of Aquaculture
    • /
    • v.16 no.4
    • /
    • pp.257-261
    • /
    • 2003
  • The effects of different stocking densities on the growth of juvenile abalone, Haliotis discus hannai and water quality in the recirculating system with rotating biological contactor, were assessed. The trials were conducted using total weight 32 g juveniles abalone for 60 days at stocking densities of 5, 10, 15 kg/$m^2$. The animals were fed sufficient amounts of the pellet diet of 30.4% protein during the experimental period. Daily feeding rate (DFR) and survival rate (SR) of 5 kg/$m^2$ showed 0.76% and 85.5% those were not significantly differed 10 kg/$m^2$ showing 0.75% and 96.0% (P>0.05). DFR and SR of 15 kg/$m^2$ showing 0.38% and 31.2% were significantly lower than 5 and 10 kg/m2 (P<0.05). Daily growth rate (DGR) and feed efficiency (FE) showed the highest as 0.19% and 24.2% in 5 kg/$m^2$ the lowest as 0.05% and 14.3% in 15 kg/$m^2$ (P<0.05). According to, these results was an inverse relationship between growth and stocking density. The optimum density of juvenile abalone from this experiment is 5 to 10 kg/$m^2$ in the recirculating system.

Removal of Suspended Solids in Aquacultural Recirculating Water by Magnetic Fluid Separation (자성 유체분리에 의한 양어장 순환수내 부유 고형물의 제거)

  • KIM Yong-Ha;YEO Ryoung-Mo;SUH Kuen-Hack;KIM Hang-Goo;CHUNG Uoo-Chang;KIM Soon-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.5
    • /
    • pp.649-653
    • /
    • 1999
  • A magnetic fluid separation technology was confirmed to be very effective to remove the suspended solids (SS) from aquacultural recirculating water, In this study, the effects of operating variables on the characteristics of SS removal were investigated through the test runs using magnetite of 2 $\mu$m mean diameter as magnetic powder. Magnetic flocculation here formed by adsorbing fine magnetites on the surface of suspended solid was observed. The strength of magnet was of significance in determining the SS removal efficiency as well as the capacity of the equipment. In addition, the SS removal efficiency decreased with an increase in the superficial liquid velocity, but the effect became negligible when the mass ratio of magnetite to the suspended solids was higher than 1.0.

  • PDF

Improvement of Water Quality by Corona Discharge Plasma-activated Water in a Tilapia Recirculating Aquaculture System (코로나 방전-플라즈마 처리수의 틸라피아 순환여과양식시스템 수질 개선 효과)

  • You, Jin Ho;Mun, Seong Hee;Oh, Hyeon Ji;Park, Tae Sup;Kwon, Joon Yeong
    • Journal of Marine Life Science
    • /
    • v.5 no.2
    • /
    • pp.51-57
    • /
    • 2020
  • Disinfection and maintenance of rearing water in aquaculture is an essential element for the prevention of fish diseases. This is especially important in recirculating aquaculture systems (RAS) in which fish are reared at high density using recycled water. In this study, tilapia was reared in two different RAS (one with plasma generator - PW system, another without plasma generator - No PW system). In plasma treated group, UVT% of water was improved clearly, and the number of heterotrophic bacteria decreased significantly after 40 days. Total weight gain of tilapia in PW system was significantly higher, and other growth indicators were also relatively higher although not statistically significant. In addition, the fish in PW system had a 100% survival rate, and there were no histological differences between fish from both systems. Fish did not seem to be affected by the toxicity of ROS. In conclusion, it is expected that plasma water can effectively deactivate fish pathogens and improve the quality of rearing water.

Performance and Flow Test of a Turbo Pump Inducer (터보 펌프 인듀서의 성능 및 유동실험)

  • Kang, Shin-Hyoung;Yeom, Ki-Tae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.6-13
    • /
    • 2003
  • Variations of performance and NPSH of a turbo pump inducer were measured. The flows at the inlet and the outlet of the inducer were also experimentally investigated by measuring flow velocity and angle using a 3-hole Pilot tube. Performance and velocity profiles show a similarity for tested speeds, however not for efficiencies. Strong recirculating flows appears at the inlet of inducer even at the design condition. Cavitating flows were also visualized at several NPSH's.

Digital variable structure control of a hot-water heating control system with long dead time (긴 지연시간을 갖는 온수난방 제어시스템의 디지틀 가변구조제어)

  • 안병천;장효환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.232-237
    • /
    • 1991
  • Digital Variable Structure Controller(DVSC) is proposed to control variable speed recirculating pump for hot-water heating control system. In this study, nonlinear sliding line is used beyond output error boundary layer and PID sliding line is used within the layer. For long dead time compensation, constraint is added to Smith predictor algorithm. Steady state error is eliminated by using the proposed sliding line in spite of heating load change. By decreasing sampling time, good sliding motion is yielded but system output noise bv flow dynamics is amplified.

  • PDF

An Experimental Study on the Wake with Swirling Flow in a Horizontal Circular Tube (수평원통관에서 선회유동의 후류에 관한 실험적 연구)

  • Kang Chang-Soo;Chang Tae-Hyun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.5-9
    • /
    • 2004
  • An experimental study is performed turbulent swirling flow behind a crcular cylinder using 2-D PIV technique. The Reynolds number investigated is 15,000. The mean velocity vector, time mean axial velocity, turbulence intensity, kinetic energy and Reynolds shear stress behind the cylinder are measured before and behind the cylinder along the test tube.

  • PDF

Experimental Study on Virtual Cyclones as Aerosol Separators (입자 분리를 위한 Virtual Cyclone의 실험적 연구)

  • Kim Dae-Seong;Xiang Rongbiao;Lee Gyu-Won
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.301-302
    • /
    • 2002
  • Virtual cyclones have been the subject of aerosol separation studies since they were first developed by Torczynski and Rader (1996). In the virtual cyclone (originally referred to as the anticyclone), the main particle-laden flow follows a wall that curves away from the original flow direction rather than curving into the original direction, as in a cyclone. Although a wall forms the inner boundary of the main flow, its outer boundary is formed by an adjacent flow, often a confined recirculating flow, into which particles are transferred by centrifugal action. (omitted)

  • PDF