• Title/Summary/Keyword: Receiver sensitivity

Search Result 592, Processing Time 0.033 seconds

Application and Efficacy Evaluation of Nutritional Screening Tool (영양부족 환자의 조기발견을 위한 선별검사의 적용 및 효용성 평가)

  • Nam, Gung-Hwan
    • Journal of Korea Association of Health Promotion
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 2006
  • "본 논문은 대한외과학회지 2006년 제70권제1호에 실렸던 논문으로 대한외과학회 편집위원회 승인을 득하고 본 협회지에 게재함. Purpose: Malnutrition has been frequently reported for patients on their admission to the hospital and it has been associated with an increase in morbidity, mortality and the length of the hospital stay. Although a number of screening tools have been developed to identify those patients at risk for malnutrition, there is no' gold standard' for defining malnutrition and the malnourished patients remain largely unrecognized. The aim of this study is to evaluate the efficacy of a nutritional screening tool for use in Dankook University Hospital. Methods Nutritional evaluation was performed for 53 patients who were admitted to the department of surgery and internal medicine between October and December 2004. The screening tool was completed by the ward nurse and the nutritional support team nurse on the same patients within24 hours of admission. The nutritional support team nurse performed the full assessment. The screening sheet included 4 questions regarding body mass index, recent unintentional weight loss, food intake and disease severity. Each answer was scored and a total of 5 was tested as the criterion fey malnutrition. The full assessment included current body weight, recent weight loss, triceps skinfold thickness, mid-arm muscle circumference, serum albumin)in and total lymphocyte count. Malnutrition was defined by 3 or more values below the reference values. The reliability of the screening tool was assessed using kappa statistic. Sensitivity, specificity and accuracy were calculated to evaluate the validity of the screening tool. The receiver operating characteristic(ROC) curve was drawn to choose a cutoff valve that maximizes sensitivity and specificity. Results' The level of agreement between the ward nurse and the NST nurse was good for BMI and food intake and moderate for weight loss and disease severity. The full assessment identified7 patients(13.2%) as malnourished. The screening sheet had a sensitivity of 86% and a specificity of 80%. According to the ROC curve, a score of 5 points provided the best validity. Conclusion The nutritional screening tool is reliable when completed by different observers and it is valid for nutritional assessment.

  • PDF

Analysis of Receiving sensitivity according to Contact Surface Change of Transmit-Receiver Ultrasonic Sensor for Fuel Level Measurement in CNG Tank (CNG 탱크 내 연료량 계측을 위한 송·수신 초음파 센서의 접촉면 변경에 따른 수신 감도 분석)

  • Kim, Nam-Wook;Im, Seok-Yeon;Choi, Doo-Seuk
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • This paper is studied, as basic research for measuring the accurate fuel amount of the CNG tank by using the transmit-receive ultrasonic sensor, the receiving sensitivity according to changed the pressure inside the tank and the contact surface of the ultrasonic sensor is analyzed. Measurement was carried out while changing the contact surface of the tank and the sensor to three shapes of Point, Line, and Surface and charging the pressure in the tank at an interval of 1 bar from 0 bar to 5 bar. Experiment results, as the pressure in the tank increased the tendency of the received signal value of the ultrasonic sensor to decrease was confirmed. As the contact area between the tank and the sensor increased, the value of the received signal increased, but the noise also increased. The results of experiment, it is judged that accuracy can be improved by changing the contact surface of the sensor.

Detection of furcation involvement using periapical radiography and 2 cone-beam computed tomography imaging protocols with and without a metallic post: An animal study

  • Salineiro, Fernanda Cristina Sales;Gialain, Ivan Onone;Kobayashi-Velasco, Solange;Pannuti, Claudio Mendes;Cavalcanti, Marcelo Gusmao Paraiso
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to assess the accuracy, sensitivity, and specificity of the diagnosis of incipient furcation involvement with periapical radiography (PR) and 2 cone-beam computed tomography (CBCT) imaging protocols, and to test metal artifact interference. Materials and Methods: Mandibular second molars in 10 macerated pig mandibles were divided into those that showed no furcation involvement and those with lesions in the furcation area. Exams using PR and 2 different CBCT imaging protocols were performed with and without a metallic post. Each image was analyzed twice by 2 observers who rated the absence or presence of furcation involvement according to a 5-point scale. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy, sensitivity, and specificity of the observations. Results: The accuracy of the CBCT imaging protocols ranged from 67.5% to 82.5% in the images obtained with a metallic post and from 72.5% to 80% in those without a metallic post. The accuracy of PR ranged from 37.5% to 55% in the images with a metallic post and from 42.5% to 62.5% in those without a metallic post. The area under the ROC curve values for the CBCT imaging protocols ranged from 0.813 to 0.802, and for PR ranged from 0.503 to 0.448. Conclusion: Both CBCT imaging protocols showed higher accuracy, sensitivity, and specificity than PR in the detection of incipient furcation involvement. Based on these results, CBCT may be considered a reliable tool for detecting incipient furcation involvement following a clinical periodontal exam, even in the presence of a metallic post.

Validation of the Short Form Bobath Memorial Hospital Fall Risk Assessment Scale at a Specialized Geriatric Hospital in Korea (단축형 노인 낙상위험 사정도구의 타당도)

  • Sohng, Kyeong-Yae;Park, Mi Hwa;Chaung, Seung Kyo;Park, Hye Ja
    • Journal of Korean Public Health Nursing
    • /
    • v.28 no.3
    • /
    • pp.495-508
    • /
    • 2014
  • Purpose: This study was conducted in order to evaluate the reliability, validity, sensitivity, and specificity of the Short Form of Bobath Memorial Hospital Fall Risk Assessment Scale (BMFRAS-SF). Methods: A validation study was conducted on 207 elderly patients aged over 65 who were admitted to Bobath Memorial Hospital. Fall risk scores of BMFRAS, composed of eight subscales (age, fall history, physical activity, consciousness level, communication, fall risk factors, underlying disease, and medications) were assessed from the electronic medical record. BMFRAS-SF was derived from eight subscales of the BMFRAS representing the significance between fallers and non-fallers (fall history, physical activity, fall risk factors, underlying disease, and medications). Internal consistency reliability and interrater reliability were assessed by Cronbach's alpha and kappa coefficient. Validity was assessed by Spearman correlation analysis, factor analysis. Sensitivity, specificity, positive predictive and negative predictive values, and a receiver-operating characteristic curve (ROC) were generated. Results: Fallers had significantly higher risk scores than non-fallers in fall history, physical activity, fall risk factors, underlying disease, and medication scales. The BMFRAS-SF demonstrated acceptable Cronbach's alpha (.706) and kappa coefficients of .95. The BMFRAS-SF subscales showed good convergent validity and construct validity. The BMFRAS-SF presented good sensitivity(86.7%), specificity(67.9%), positive predictive value(42.9%) and good negative predictive value(94.8%) at a cut-off score of 5. Areas under the ROC curves were .860 for the BMFRAS and .861 for the BMFRAS-SF. Conclusion: The BMFRAS-SF was proved to be reliable and valid. It could be used for time-saving assessment and evaluation of the high risks for falls in clinical practice settings.

Accuracy of the 2008 Simplified Criteria for the Diagnosis of Autoimmune Hepatitis in Children

  • Arcos-Machancoses, Jose Vicente;Busoms, Cristina Molera;Tatis, Ecaterina Julio;Bovo, Maria Victoria;Bernabeu, Jesus Quintero;Goni, Javier Juamperez;Martinez, Vanessa Crujeiras;Martin de Carpi, Javier
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.2
    • /
    • pp.118-126
    • /
    • 2018
  • Purpose: Classical criteria for diagnosis of autoimmune hepatitis (AIH) are intended as research tool and are difficult to apply at patient's bedside. We aimed to study the accuracy of simplified criteria and the concordance with the expert diagnosis based on the original criteria. Methods: A cohort of children under study for liver disorder was selected through consecutive sampling to obtain the prevalence of AIH within the group of differential diagnoses. AIH was defined, based on classical criteria, through committee review of medical reports. Validity indicators of the simplified criteria were obtained in an intention to diagnose approach. Optimal cut-off and the area under the receiver operating characteristic (ROC) curve were calculated. Results: Out of 212 cases reviewed, 47.2% were AIH. For the optimal cut-off (6 points), the simplified criteria showed a sensitivity of 72.0% and a specificity of 96.4%, with a 94.7% positive and a 79.4% negative predictive value. The area under the ROC curve was 94.3%. There was a good agreement in the pre-treatment concordance between the classical and the simplified criteria (kappa index, 0.775). Conclusion: Simplified criteria provide a moderate sensitivity for the diagnosis of AIH, but may help in indicating treatment in cases under suspicion with 6 or more points.

Assessing the Diagnostic Value of Serum Dickkopf-related Protein 1 Levels in Cancer Detection: a Case-control Study and Meta-analysis

  • Jiang, Xiao-Ting;Ma, Ying-Yu;Guo, Kun;Xia, Ying-Jie;Wang, Hui-Ju;Li, Li;He, Xu-Jun;Huang, Dong-Sheng;Tao, Hou-Quan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9077-9083
    • /
    • 2014
  • Background: This study aimed to summarize the potential diagnostic value of serum DKK1 levels in cancer detection. Materials and Methods: Serum DKK1 was measured using enzyme-linked immunosorbent assay in a case-control study. Then we performed a meta-analysis and the pooled sensitivity, specificity, diagnostic odds ratio, and summary receiver operating characteristic (sROC) curves were used to evaluate the overall test performance. Results: Serum DKK1 levels were found to be significantly upregulated in gastric cancer as compared to controls. ROC curve analysis revealed an AUC of 0.636, indicating the test has the potential to diagnose cancer with poor accuracy. The summary estimates of the pooled sensitivity, specificity and diagnostic odds ratio in meta-analysis were 0.55 with a 95% confidence interval (CI) (0.53-0.57), 0.86 (95%CI, 0.84-0.88) and 12.25 (95%CI, 5.31-28.28), respectively. The area under the sROC was 0.85. Subgroup analysis revealed that the diagnostic accuracy of serum DKK1 in lung cancer (sensitivity: 0.69 with 95%CI, 0.66-0.74; specificity: 0.95 with 95%CI, 0.92-0.97; diagnostic odds ratio: 44.93 with 95%CI, 26.19-77.08) was significantly higher than for any other cancer. Conclusions: Serum DKK1 might be useful as a noninvasive method for confirmation of cancer diagnosis, particularly in the case of lung cancer.

Value of Combined Detection of Serum CEA, CA72-4, CA19-9 and TSGF in the Diagnosis of Gastric Cancer

  • Yin, Li-Kui;Sun, Xue-Qing;Mou, Dong-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3867-3870
    • /
    • 2015
  • Background: To explore whether combined detection of serum tumor markers (CEA, CA72-4, CA19-9 and TSGF) improve the sensitivity and accuracy in the diagnosis of gastric cancer (GC). Materials and Methods: An automatic chemiluminescence immune analyzer with matched kits were used to determine the levels of serum CEA, CA72-4, CA19-9 and TSGF in 45 patients with gastric cancer (GC group), 40 patients with gastric benign diseases (GBD group) hospitalized in the same period and 30 healthy people undergoing a physical examination. The values of those 4 tumor markers in the diagnosis of gastric cancer was analyzed. Results: The levels of serum CEA, CA72-4, CA19-9 and TSGF of the GC group were higher than those of the GBD group and healthy examined people and the differences were significant (P<0.001). The area under receiver operating characteristic (ROC) curves for single detection of CEA, CA72-4, CA19-9 and TSGF in the diagnosis of GC was 0.833, 0.805, 0.810 and 0.839, respectively. The optimal cutoff values for these 4 indices were 2.36 ng/mL, 3.06 U/mL, 5.72 U/mL and 60.7 U/mL, respectively. With combined detection of tumor markers, the diagnostic power of those 4 indices was best, with an area under the ROC curve of 0.913 (95%CI 0.866~0.985), a sensitivity of 88.9% and a diagnostic accuracy of 90.4%. Conclusions: Combined detection of serum CEA, CA72-4, CA19-9 and TSGF increases the sensitivity and accuracy in diagnosis of GC, so it can be regarded as the important means for early diagnosis.

MicroRNAs as Promising Biomarkers for Tumor-staging: Evaluation of MiR21 MiR155 MiR29a and MiR92a in Predicting Tumor Stage of Rectal Cancer

  • Yang, Yun;Peng, Wei;Tang, Tian;Xia, Lin;Wang, Xiao-Dong;Duan, Bao-Feng;Shu, Ye
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5175-5180
    • /
    • 2014
  • Objective: In this study, tumor-stage predictive abilities of miR21, miR155, miR29a and miR92a were evaluated in rectal cancer (RC). Methods: Expression of miR21, miR155, miR29a and miR92a was detected and quantitated in tumor tissue and in adjacent normal tissue from 40 patients by TaqMan MicroRNA assay. Results: Significant overexpression of miR21, miR155, miR29a and miR92a was observed in RC tissues. While high expression of miR21, miR155 and miR29a in N1-2 and C-D stages presented a potential correlation with N and Duke stages, partial correlation analysis suggested that only miR155 rather than miR21 and miR29a played a greater influencing role. Receiver operating characteristics (ROC) curve analysis showed that miR155 could discriminate N0 from N1-2 with 85.0% sensitivity and 85.0% specificity, N2 from N0-1 with 90.0% sensitivity and 96.7% specificity, and C-D stage from A-B stage with 81.0% sensitivity and 84.2% specificity. Conclusions: Increase in expression of miR155 might represent a novel predictor for RC N and Dukes staging.

Diagnostic accuracy of a combination of salivary hemoglobin levels, self-report questionnaires, and age in periodontitis screening

  • Maeng, You-Jin;Kim, Bo-Ra;Jung, Hoi-In;Jung, Ui-Won;Kim, Hee Eun;Kim, Baek-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.1
    • /
    • pp.10-21
    • /
    • 2016
  • Purpose: This study evaluated the predictive performance of a combination of self-report questionnaires, salivary hemoglobin levels, and age as a non-invasive screening method for periodontitis. Methods: The periodontitis status of 202 adults was examined using salivary hemoglobin levels, responses to 10 questions on a self-report questionnaire, and the Community Periodontal Index (CPI). The ability of those two variables and the combination thereof with age to predict the presence of CPI scores of 3-4 and 4 was assessed using logistic regression and receiver operating characteristic (ROC) curve analysis. Results: CPI scores of 3-4 and 4 were present among 79.7% and 46.5% of the sample, respectively. The area under the ROC curves (AUROCs) of salivary hemoglobin levels for predicting prevalence of CPI scores of 3-4 and 4 were 0.63 and 0.67, respectively (with sensitivity values of 71% and 60% and specificity values of 56% and 72%, respectively). Two distinct sets of five questions were associated with CPI scores of 3-4 and 4, with AUROCs of 0.73 and 0.71, sensitivity values of 76% and 66%, and specificity values of 63% and 69%. The combined model incorporating both variables and age showed the best predictive performance, with AUROCs of 0.78 and 0.76, sensitivity values of 71% and 65%, and specificity values of 68% and 77% for CPI scores of 3-4 and 4, respectively. Conclusions: The combination of salivary hemoglobin levels and self-report questionnaires was shown to be a valuable screening method for detecting periodontitis.

Use of positron emission tomography-computed tomography to predict axillary metastasis in patients with triple-negative breast cancer

  • Youm, Jung Hyun;Chung, Yoona;Yang, You Jung;Han, Sang Ah;Song, Jeong Yoon
    • Korean Journal of Clinical Oncology
    • /
    • v.14 no.2
    • /
    • pp.135-141
    • /
    • 2018
  • Purpose: Axillary lymph node dissection (ALND) and sentinel lymph node biopsy (SLNB) are important for staging of patients with node-positive breast cancer. However, these can be avoided in select micrometastatic diseases, preventing postoperative complications. The present study evaluated the ability of axillary lymph node maximum standardized uptake value (SUVmax) on positron emission tomography-computed tomography (PET-CT) to predict axillary metastasis of breast cancer. Methods: The records of invasive breast cancer patients who underwent pretreatment (surgery and/or chemotherapy) PET-CT between January 2006 and December 2014 were reviewed. ALNs were preoperatively evaluated by PET-CT. Lymph nodes were dissected by SLNB or ALND. SUVmax was measured in both the axillary lymph node and primary tumor. Student t-test and chi-square test were used to analyze sensitivity and specificity. Receiver operating characteristic (ROC) and area under the ROC curve (AUC) analyses were performed. Results: SUV-tumor (SUV-T) and SUV-lymph node (SUV-LN) were significantly higher in the triple-negative breast cancer (TNBC) group than in other groups (SUV-T: 5.99, P<0.01; SUV-LN: 1.29, P=0.014). The sensitivity (0.881) and accuracy (0.804) for initial ALN staging were higher in fine needle aspiration+PET-CT than in other methods. For PET-CT alone, the subtype with the highest sensitivity (0.870) and negative predictive value (0.917) was TNBC. The AUC for SUV-LN was greatest in TNBC (0.797). Conclusion: The characteristics of SUV-T and SUV-LN differed according to immunohistochemistry subtype. Compared to other subtypes, the true positivity of axillary metastasis on PET-CT was highest in TNBC. These findings could help tailor management for therapeutic and diagnostic purposes.