• Title/Summary/Keyword: Receiver Module

Search Result 325, Processing Time 0.028 seconds

A Development of Ultrasonic Based Distance Meter Through Detachment of Receiving and Transmitting Capacitive Ultrasonic Transducer (송.수신 분리형 초음파 거리 측정기 개발)

  • Kim Jung-Hoon;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.41-50
    • /
    • 2006
  • This paper presents a novel ultrasonic sensor system to overcome limited distance detection range that can be measured only more than 30cm by single ultrasonic transducer. This is accomplished by separation of receiving capacitive ultrasonic transducer from transmitting capacitive ultrasonic transducer. And hardwares and software of the system are described in detail. The system makes very close range as well as long range detect by wireless precisely. Frequency of trigger pulse is 10Hz, but it is very low frequency for transmitting data in wireless module. Therefore, for triggering between receiver and transmitter, an algorithm for mixing and distinguishing trigger pulse from carrier pulse by software is proposed. The system is designed by common microprocessor 8051. The performance of the proposed method has been assessed through two types. The first, transmitting and receiving transducer are put on both sides. And then, distance of two point is measured as far as 0mm. Secondly, transmitting transducer send out ultrasonic pulse and measure the time of flight(TOF) until a first echo from an object detected by the detached receiving transducer. The distance between the detached transducers and a reflecting object is measured as far as 7cm. Images of measured ultrasonic waves and TOF for two methods presented to prove effectiveness of results.

A Design and Implementation of Digital Ultra-Narrowband Walky-Talky Using Direct Conversion Method (직접 변환 방식을 이용한 디지털 초협대역 무전기 설계 및 구현)

  • Chong Young-Jun;Kang Min-Soo;Yoo Sung-Jin;Chung Tae-Jin;Oh Seung-Hyeub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.603-614
    • /
    • 2005
  • In this paper, digital ultra-narrowband Walky-Talky using direct conversion method for CQPSK modulation scheme is implemented with satisfying the requirements of APCO P25. RF transceiver design and implementation scheme that minimize the influence of DC-offset and AC-coupling at ultra-narrowband is proposed. This scheme also minimizes the influence of nonlinear characteristic at power amplifier fir CQPSK modulation method. Test results of full system including DSP module and direct conversion RF transceiver show that FCC emission mask at 36.8 dBm PEP meets the standard requirements. The characteristic of receiver AGC by PWM control signal is linear at 40 dB dynamic range and voice communication at input power level of -116 dBm is successful. Also it is verified that the performance of BER versus frequency offset and versus SNR meets the standard requirements.

A Development of DDS Based Chirp Signal Generator and X-Band Transmitter-Receiver for Small SAR Sensor (DDS 기반의 소형 SAR 시스템 송수신장비 개발)

  • Song, Kyoung-Min;Lee, Ki-Woong;Lee, Chang-Hyun;Lee, Woo-Kyung;Lee, Myeong-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.326-329
    • /
    • 2016
  • UAVs(Unmanned Aerial Vehicle) can be used in variant fields fornot only combat, but also recon, observation and exploration. Moreover, UAVs capacity can be expanded to impossible missions for existing surveillance system such as SAR(Synthetic Aperture Radar) technology that collecting images from all weather conditions. In recent days, with development of highly efficient IC and lightened system technology, there are significant increase of researches and demands to make SAR sensor as a payload of UAV. Therefore, this paper contains development process and results of small signal generator and RF device as a core module of SAR system based on the digital device of DDS.

Design of an AM Radar Module with Improved Range Accuracy (거리 측정 정확도를 개선한 AM 레이더 모듈 설계)

  • Choi, Mun-Gak;Woo, Dong-Sik;Kang, Il-Heung;No, Hyung-Woo;Kim, Kang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.8
    • /
    • pp.911-918
    • /
    • 2010
  • With limitation of frequency bandwidth, the range accuracy of typical radars is limited. In this paper, for short distance measurements, the use of an AM(Amplitude Modulated) radar which provides improved range accuracy is proposed. The AM radar signal consists of a carrier frequency signal and double-sideband components. The fabricated AM radar operates with +10 dBm output power and 35 dB receiver gain at 24.128 GHz center frequency with 20 MHz bandwidth, and the range accuracy is measured as ${\pm}15\;cm$.

Development of Polarization-Controllable Active Phased Array Antenna for Receiving Satellite Broadcasting (편파가변 위성 방송 수신용 능동 위상 배열 안테나 개발)

  • Choi, Jin-Young;Lee, Ho-Seon;Kong, Tong-Ook;Chun, Jong-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.5
    • /
    • pp.325-335
    • /
    • 2018
  • We herein present a study on the active phased array antenna for receiving satellite broadcasting that can electrically align its polarization to that of target transmitters in its moving condition or in the Skew angle arrangement of the broadcasting satellite receiver. Hence, we have developed an active phased array structure composed of the self-developed Vivaldi antenna and multifunction core (MFC) chip, receiving RF front end module, and control units. In particular, the new Vivaldi antenna designed in the Ku-band of 10.7 - 14.5 GHz to receive one desired polarization mode such as the horizontal or vertical by means of an MFC chip and other control units that can control the amplitude and phase of each antenna element. The test results verified that cross-polarization property is 20 dB or higher and the primary beam can be scanned clearly at approximately ${\pm}60^{\circ}$.

In-hole seismic method for measuring dynamic properties of soils (지반물성치 측정을 위한 인흘탄성파시험)

  • Mok Young Jin;Kim Young Su;You Chang Yeon;Han Man Jin
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.117-123
    • /
    • 2005
  • An in-hole seismic tests, which has been developed for measuring dynamic properties of soils and rock mass, is a bore hole seismic method that has cost effectiveness and practicality. The upgraded features include the motorized triggering system rather than the manual prototype version in the previous studies and a damper between source and receiver in the module. The performance of the probe has been verified through extensive cross-hole tests and in-hole tests at various sites. The dynamic stiffness of subsurface materials and rock mass have been evaluated and recently, the measurement of shear wave velocity was successfully adopted at horizontal holes of tunnel-face to install explosives. So the application of in-hole seismic test for various soil materials was certified.

  • PDF

Design and Implementation of Multi-Channel WLL RF-module for Multimedia Transmission (멀티미디어 전송을 위한 무선가입자용 RF-모듈의 설계 및 제작)

  • Kim, Sang-Tae;Shin, Chull-Chai
    • Journal of IKEEE
    • /
    • v.3 no.2 s.5
    • /
    • pp.186-195
    • /
    • 1999
  • In this paper, the RF-modules composed of front-end, frequency synthesizer, modulator/demodulator and power control multi channel WLL personal system for W-CDMA using 10 [MHz] RF channel bandwidth has been implemented and considered. The measured transmission power is 250 [mW] which is very close to the required value. The measured flatness of power at the final output stage is ${\pm}1.5[dB]$ over the required bandwidth of the receiver. In addition, it is found that the chip rate transmitting spread signal is set to 8.192 [MHz], the required rate. The frequencies of RF_LO signal and LO signal of the modulator and the demodulator measured by a frequency synthesizer are satisfied with design requirements. The operating range of the receiving strength signal indicator and AGC units shows 60 [dB] respectively. Also the measured phasor diagram and eye pattern for deciding the RF modules compatible with baseband digital signal processing part are shown good results.

  • PDF

Implementation of AIS Transponder with a New Time Synchronization Method (새로운 시각 동기 방안을 적용한 자동 식별 장치의 구현)

  • 이상정;최일흥;오상헌;윤상준;박찬식;황동환
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.7
    • /
    • pp.273-281
    • /
    • 2003
  • This paper proposes a new time synchronization scheme for the Automatic Identification System(AIS). The proposed scheme utilizes a Temperature Compensated Crystal Oscillator(TCXO) as a local reference clock, and consists of a Digitally Controlled Oscillator(DCO), a divider, a phase comparator, and register blocks. Primary time reference is IPPS from GPS receiver that is synchronized to Universal Time Coordinated(UTC). And if GPS is unavailable, other station's signal is utilized as secondary time reference. The phase comparator measures time difference between the 1PPS and the generated transmit clock. The measured time difference is compensated by controlling the DCO and the transmit clock is synchronized to the Universal Time Coordinated(UTC). The synchronized transmit clock(9600Hz) is divided into the transmitting time slot(37.5Hz). The proposed scheme is tested in an experimental AIS transponder set. The experimental result shows that the proposed module satisfies the timing specification of the AIS technical standard, ITU-R M.1371-1.

The Implementation of Patient Vital Sign Information Telemedicine System using TMO in Distributed Network Enviroment (분산 네트워크 환경하에서 TMO를 이용한 중환자 생체정보 원격 진료 시스템 구현)

  • Kim, Gwang-Jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1128-1140
    • /
    • 2009
  • In this paper, we present a patient real-time vital sign information transmission system to effectively support developing real-time communication service by using a real-time object model named TMO (Time-Triggered Message-Triggered Object). Also, we describe the application environment as the ICU(Intensive Care Unit) to guarantee real-time service message with TMO structure in distributed network systems. We have to design to obtain useful vital sign information, which is generated at parsing data receiver modulor of HIS with TMO structure, that is offered by the central monitor. Vital sign informations of central monitor is composed of the raw data of several bedsite patient monitors. We are willing to maintain vital sign information of real time and continuity that is generated from the bedsite patient monitor. It is able to apply to remote medical examination and treatment. we proposed integration method between a vital sign database systems and hospital information systems. In the real time simulation techniques based on TMO object modeling, We have observed several advantages to the TMO structuring scheme. TMO object modeling has a strong traceability between requirement specification and design.

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.