• 제목/요약/키워드: Receiver Coil

검색결과 67건 처리시간 0.023초

진단용 자기공명영상장치의 삽입 코일에 관한 연구 (A Study on the Insertional Coil of MRI Device for Diagnosis)

  • 이용문;임근호;서대건;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 학술대회 논문집 일렉트렛트 및 응용기술연구회
    • /
    • pp.33-37
    • /
    • 2003
  • Endovaginal and endorectal receiver only surface coil were designed for MR imaging(MRI) and $^1H$ MR spectroscopy(MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round comer. The shape of endorectal coil wire was long elliptic shape during insertion and circular shape after insertion. Conventional spin echo and fast spin echo sequences were used as T1 and T2 weighted imaging sequences, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method. Using home-built endvaginal and endorectal coils, excellent T1 and T2 images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo $^1H$ MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI

  • Ryu, Yeun Chul
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.238-243
    • /
    • 2017
  • In this research, we report the preliminary results of an insertional type parallel transmission (pTx) array that has 7-elements that are placed in the space above a patient table as a transmit (Tx) coil to give an RF transmission ($B_1{^+}$) field for the body object of a 3 Tesla (T) MRI system. In previous research, we have tried to compare the performances of different coil elements and array geometries for a pTx body image. Based on these results, we attempt to obtain a human image with the proposed pTx array. Through the simulation and experimental results, we introduce a possible structure of multi-channel Tx array and verify the utility of a multi-channel Tx body image using $B_1{^+}$ shimming. The insertional pTx array, combined with a receiver (Rx) array coil, provides an enhanced $B_1{^+}$ field homogeneity in a large ROI image as a result of $B_1{^+}$ shimming applied over the full body size object. Through this research, we hope to determine the usefulness of the proposed insertional type RF coil combination for 3 T body imaging.

수신 코일 권선 수 변화에 의한 무선전력전송 최적 부하 구현 (Realization of Optimum Loads for Maximum WPT Efficiencies Using Multi-Turn Receiving Coil)

  • 황성연;이범선
    • 한국전자파학회논문지
    • /
    • 제27권4호
    • /
    • pp.335-341
    • /
    • 2016
  • 본 논문에서는 최대 무선전력전송 효율 구현에 필요한 최적 부하저항을 수신기 입력 임피던스(통상 $50{\Omega}$)에 바로 정합하기 위하여 수신 코일의 권선 수를 제어하는 방법을 제안한다. 수신 코일 권선 수와 도선 사이의 근접 효과가 고려된 최적 부하저항의 수식에 따라 수신 코일을 설계, 제작 및 측정하였다. 이론과 EM 시뮬레이션, 측정을 통하여 최적 부하 저항과 효율을 비교한 결과 비교적 잘 일치함을 확인할 수 있었다. 본 논문의 결과를 활용하면 별도의 급전 루프 없는 단순하고 부피가 작은 2-coil 시스템으로도 허용된 최대 전력을 구현할 수 있다.

자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광 (Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy)

  • 문치웅;조경식
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권4호
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

경사진 헬리컬 코일 열교환기의 열전달 특성에 관한 연구 (Heat Transfer Characteristics of Inclined Helical Coil Type Heat Exchanger)

  • 손창효;전민주;장승일;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.707-714
    • /
    • 2007
  • The heat transfer coefficient and Pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45mm inner diameter. The refrigerant mass fluxes were varied from 200 to $600[kg/m^2s]$ and the inlet Pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increases with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those Predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However, at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al. correlation. Therefore. various experiments in the inclined helical coil tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in the inclined helical coil tubes.

코일직경변화에 따른 헬리컬 코일형 가스냉각기내 초임계 이산화탄소의 냉각열전달 특성 (Heat Transfer Characteristics of Supercritical $CO_2$ in Helical Coil Gas Coolers on the Change of Coil Diameters)

  • 손창효
    • 한국가스학회지
    • /
    • 제11권3호
    • /
    • pp.44-48
    • /
    • 2007
  • 본 연구는 코일직경변화에 따른 헬리컬 코일 가스냉각기내 초임계 $CO_2$의 냉각 열전달 특성에 대해 실험적으로 조사하였다. 냉매 순환루프의 주요구성품은 수액기, 변속펌프, 질량유량계, 예열기, 헬리컬 코일형 가스냉각기(시험부)로 구성된다. 시험부는 내경 4.55 mm의 평활 동관과 26.75 mm와 41.35 mm인 코일직경으로 이루어져 있다. 냉매질량유속은 $200kg/m^2s$에서 $800kg/m^2s$가지 변화시켰고, 가스냉각기의 입구압력 범위는 7.5 MPa에서 10.0 MPa까지이다. 코일직경이 26.75 mm인 가스냉각기내 이산화탄소의 냉각열전달 계수가 코일직경이 41.35 mm인 열전달 계수보다 높은 것으로 나타났다. 또한 초임계 상태에서 제안한 종래의 냉각 열전달 상관식과 비교한 결과, 대부분의 상관식이 과소예측되었고, 그 중에서도 이산화탄소의 냉각 열전달 계수는 Pilta 등이 제안한 상관식과 좋은 일치를 보였다. 하지만, 유사임계 온도 영역부근에서는 실험데이터가 더 큰 것으로 나타났다.

  • PDF

회전자계 역수신 코일을 이용한 관벽의 자기공명영상

  • 문치웅;조종운;백문영;조지연;박청수;신운재;이현용;은충기
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.176-176
    • /
    • 2001
  • 목적: 기존의 역수신코일(inside-out receiver coil)로 관벽의 MR 영상을 얻을 때 영상영역이 좁고 수신감도가 불균일한 단점을 보완하면서 신호대 잡음비(S/N ratio)도 높일 수 있는 회전자계역수 신코일(quadratic inside-out receiver coil)의 개발을 목적으로 한다. 대상 및 방법: 8극형코일, 선형자계수신코일, 회전자계수신코일에 대하여 컴퓨터 모의실험으로 영상영역 및 감도의 균일성을 비교하였다. 회전자계수신코일은 안장 모양을 한 두 개의 선형자계코일이 서로 간섭이 일어나지 않도록 수직 방향으로 배열된 구조를 갖도록 하였다. 지름 3 cm 크기로 각 코일을 제작하였으며 지름 20 cm의 원통 중앙에 내경 4 cm의 관이 있는 팬텀을 만들어 MnC1$_2$를 섞은 물을 채운 다음 1.5T 초전도 MRI 장치와 0.3T 영구자석 MRI 장치에서 팬텀의 관벽 영상을 얻었다. 본 실험을 시행한 1.5T 장치의 구조 때문에 회전자계코일의 두 안장코일을 결합하는 회로를 제작하여 사용하였고 0.3T에서는 장치에 내장된 결합회로를 사용하였다. 또한 포르말린 용액에 보관된 소의 대장 조직 단면 영상을 FOV 10-12 cm로 얻어 회전자 계안장코일의 성능을 평가하였다.

  • PDF

헬리컬 코일형 가스냉각기 내 CO2의 냉각 열전달 특성 (Cooling Heat Transfer Characteristics of CO2 in Helical Coil Type Gas Coolers)

  • 손창효;전민주;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.699-706
    • /
    • 2007
  • The cooling heat transfer coefficient and pressure drop of $CO_2$(R-744) in helical coil copper tubes were investigated experimentally The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter. a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55mm inner diameter The refrigerant mass fluxes were varied from 200 to $600 [kg/m^2s]$ and the inlet pressures of 9as cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively food agreement with those Predicted by Ito's correlation developed for single-phase in helical coil tubes. Though a few correlation available with the data. the local heat transfer coefficient of $CO_2$ agrees well with those presented by Pitla et al. among the predictions. However at the region near pseudo-critical temperature. the experiment data indicate higher values than the Pitla et al. correlation.

내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구 (Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm)

  • 손창효
    • 한국가스학회지
    • /
    • 제11권3호
    • /
    • pp.1-6
    • /
    • 2007
  • 본 연구에서는 경사진 헬리컬 코일형 동관내 이산화탄소의 증발 열전달 계수와 압력강하를 실험적으로 조사하였다. 냉매 순환루프의 주요구성품은 수액기, 변속펌프, 질량유량계, 예열기, 경사진 헬리컬 코일형 가스냉각기(시험부)로 구성된다. 시험부는 내경 4.55 mm의 평활 동관으로 이루어져 있다. 냉매질량 유속은 $200kg/m^2s$에서 $600kg/m^2s$까지 변화시켰고, 가스냉각기의 입구압력은 7.5 MPa에서 10.0 MPa까지이다. 경사진 헬리컬 코일관내 이산화탄소의 열전달 계수는 질량유속과 냉각압력의 증가와 함께 따라 증가하였다. 이산화탄소의 압력강하는 헬리컬 코일관내 단상 상관식인 Ito식과 좋은 일치를 보였고, 이산화탄소의 국소 열전달 계수는 Pilta 등이 제안한 상관식과 좋은 일치를 보였다. 하지만, 유사임계 온도 영역부근에서는 실험데이터가 더 높게 나타났다.

  • PDF

고자장 3T MRI 장비에서 동물영상을 위한 솔레노이드 RF코일 개발 (Development of Solenoid RF Coil for Animal Imaging in 3T High Magnetic Field MRI)

  • 이홍석;우동철;민광홍;김용권;이흥규;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권1호
    • /
    • pp.20-26
    • /
    • 2007
  • 목적 : 본 연구는 3 T MRI 장비에 적합한 동물영상용 솔레노이드 (solenoid) 코일을 개발하고 최적화한 후, 실제 동물모델에 대한 영상을 획득하는 것을 목표로 수행되었다. 대상 및 방법 : 솔레노이드 코일은 반경 4 cm, 길이 10 cm의 아크릴 구조물에 너비 2 cm, 두께 0.05 cm, 길이 10 cm의 구리테잎으로 3번 감긴 형태로 제작하였고, 구리테잎을 감을 때는 실린더 축과 수직이 되도록 감았으며 테잎간의 간격은 2 cm로 하였다. 축전지(capacitor)는 2-100 pF사이의 용량을 이용하였고, 코일은 수신 전용으로서 디자인되었다. 결과 : 개발된 솔레노이드 코일의 신호대 잡음비 (Signal to Noise Ratio; SNR)는 CuSO4수용액 팬텀(CuSO4; 0.7 g/L)에서 985, 쥐 (rat)를 이용한 동물실험에서 995이었고, Qfactor는 unload된 경우 203-206, load된 경우 84-89정도로 측정되었다. 솔레노이드 코일을 이용하여 획득한 영상은 상대적으로 해상도 (resolution)가 높았으며, 코일 시뮬레이션(simulation)을 통해서 얻은 RF field의 균질성 (homogeneity) 또한 매우 우수하였다. 결론 : 본 연구를 통하여 고자장 3T MRI 장비에서 쥐와 같은 작은 동물의 영상을 획득할 때 솔레노이드 코일을 사용하면 보다 향상된 영상의 대조도, 해상도, 선명도를 얻을 수 있는 가능성을 확인 할 수 있었다.

  • PDF