• Title/Summary/Keyword: Realtime Measurement

Search Result 96, Processing Time 0.034 seconds

Development of Automatic Measurement and Inspection System for ALC Block Using Camera (카메라를 이용한 ALC 블록의 치수계측 및 불량검사 자동화 시스템 개발)

  • 허경무;김성훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.448-455
    • /
    • 2003
  • A system design technique of automatic thickness measurement and defect inspection system, which measures the thickness of the ALC(Autoclaved Lightweight Concrete) block and inspects the defect on a realtime basis is proposed. The image processing system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. The image obtained by this system was analyzed by a devised algorithm, specially designed for the enhanced measurement accuracy. For the realization of the proposed algorithm, the preprocessing method that can be applied to overcome uneven lighting environment, an enhanced edge decision method using 8 edge-pairs with irregular and rough surface, the unit length decision method in uneven condition with rocking objects, and the curvature calibration method of camera using a constructed grid are developed. The experimental results, show that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

A Design on the Digital Protective Relay System for Generator Fault Diagnosis (발전기 고장진단을 위한 디지털보호계전 시스템 설계)

  • Lee, Sung-Hwan;Jang, Nak-Won;Yi, Dong-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.717-718
    • /
    • 2008
  • We developed the protection program for the generator fault protection system and each module of the digital protective relay H/W for loading the protection program. The protective algorithm for the generator is 51, 51G/N, 46P/N, 47P/N, 50G/N, and 32, and we developed each fault protection program. And we must design high efficiency microprocessor, CT, and PT for realtime measuring, relaying and high accuracy of measurement, also. From now on digital protective relay must be operated with integrated management systems. For this point, we must load various industrial protocol on the digital protective relay. In this research, we developed each protective relay H/W module according to above conditions. And we designed real-time operating system in order that each protective algorithm is operated with realtime processing on the H/W system.

  • PDF

FIBER OPTIC SENSOR FOR IN-SITU AND REALTIME MONITORING OF TRANSPORT OF GAS PHASE OZONE IN UNSATURATED POROUS MEDIA

  • Jung, Hae-Ryong;Park, Hee-Chul
    • Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • A series of column experiments was conducted to develop a monitoring system for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone were obtained by converting the normalized intensity into ozone concentration. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of soil organic matter (SOM). However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

The Optimum Displacement Measurement to estimate Realtime States of Beam Structure (최적 변위 계측 방법에 의한 교량 휨부재의 상태 평가)

  • Kim, Hyung-Joong;Kim, Sung-Nam;Han, Taek-Hee;Kang, Young-Jong
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.376-380
    • /
    • 2006
  • There are several methods which estimate the behavior of the Structures. Recently, several displacement measuring instruments such a GPS are substantially developed. So, considering this technique, displacement measurement will be a very efficient method for estimating the behavior of the Structures and maintenance. Therefore we need to develop methods of structure maintenance & management by using displacement measuring instruments. In this study, I suggest to maintenance & management method by using displacements about simple beams and cantilever beams which are very important structure in civil engineering. The results show that the proposed method is capable of estimating the displacement and stress of the Beam Member by combining the proper number of measurement and optimum measurement points.

  • PDF

Realtime Measurement of Impedance Locus using Impedance Spectroscopy: How Many and How Low Frequencies Are Required \ulcorner

  • T., Fukumoto;G. M., Eom;S., Ohba;N., Hoshimiya
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1194-1197
    • /
    • 2004
  • High temporal-resolution and accurate measurement of skin impedance locus provides useful data for the identification of the physiological/psychological changes and also the identification of acupuncture point. An impedance spectroscopy method using digitally constructed current waveform consisting of many frequency components (multiples of 1Hz) was reported3. The time resolution of the method depends on the lowest frequency used in the waveform construction, and therefore, the measurement would be faster if the lowest frequency is the higher. However, it was not clear that how many and how low frequencies must be used for the estimation of the skin impedance parameters from which the impedance locus can be drawn. This study shows the relationship between the estimation error of the impedance parameters and the frequency coverage of the spectroscopy. The results of this study are expected to serve as the reference of the frequency selection in the impedance spectroscopy.

  • PDF

A study on the measurement of harmonics in the distribution system and the configuration of DB (배전 계통의 고조파 측정 및 DB 구축에 대한 연구)

  • Park, Yong-Up;Kang, Moon-Ho;Jo, Nam-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.202-203
    • /
    • 2006
  • The equipment using the Power electronic device is recently increased in the distribution system, so power utility and customers increase in concerning about harmonics level. Accordingly, The power utility which prepares a measure for the harmonic public standard and manege process must analysis of the harmonics level and the effect on equipment interconnecting distribution system. In the past, the measurement equipment and technique is imperfect, so very difficult to investigate the harmonics and trend. But the improvement of the measurement equipment recently is possible to obtain the data realtime for harmonic analysis. In this paper, we research the measuring domestic harmonic and constructing of DB based on the IEC standard.

  • PDF

Development of Eye Protection App using Realtime Eye Tracking and Distance Measurement Method (실시간 시선 추적과 거리 측정 기법을 활용한 눈 보호 앱 개발)

  • Lee, Hye-Ran;Lee, Jun Pyo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.223-224
    • /
    • 2019
  • 본 논문에서는 카메라의 실시간 영상에서 얻을 수 있는 데이터를 수집 및 분석하여 일반인들에게 스마트폰의 실제 사용량, 최적화면 표현, 그리고 건조증 위험도의 정보를 제공하는 "i-eye" 응용 앱을 제안하여 눈 건강관리를 가능하게 한다. 제안하는 앱은 발전된 스마트 폰을 기반으로 동작되며 아이트래킹(eye-gaze tracking), 영상거리측정(image distance measurement), 눈 데이터분석(eye data analysis)의 3가지 핵심기술을 제안한다.

  • PDF

The Measurement Method of Reflected Intensity of Radiation for High Precision Laser Range Finder (고정밀 레이저 변위기용 반사 광량 측정 기법)

  • Bae, Young-Chul;Cho, Eui-Joo;Lee, Hyen-Jae;Kim, Sung-Hyen;Kim, Hyeon-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.1
    • /
    • pp.34-40
    • /
    • 2009
  • The phase delay of output signal of APD(avalanche photo diode) caused by intensity of reflected light which comes from target. These difference of phase delay is an one of the main reason of measurement error, but there is no reasonable measurement meter and method to detect it. In this paper, to solve the problem, we propose and implement a method to measure the intensity of radiation. The method measures DC voltage which is proportional to the reflected intensity of radiation and come out from APD in receiver by realtime.

  • PDF

A Measurement Method of Internal Defects of Pressure Vessles by Using Real-Time Holographic Interferometry (실시간 홀로그래픽 간섭법을 이용한 압력용기의 내부결함 측정법)

  • Moon, Sang-Joon;Kang, Young-June;Baik, Sung-Hoon;Kim, Cheol-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1233-1240
    • /
    • 1996
  • Conventional measurement methods using ultrasonic wave or x-ray, eddy current for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been utilized as the method of contact with objects to be inspected. For this reason these methods require relatively much time and inspection area is limited by the location of probe or film. But holograpic interferometry which is a non-contact optical measurement method using a coherent light source has an advantage that quantative measurement can be performed at a time. In this paper a new method using realtime holographic interfreometry and image processing for detecting internal flaws of pressure vessels is presented.

An Efficient QoE-Aware Transport Stream Assessment Schemes for Realtime Mobile IPTV's Distorting Contents Evaluation (실시간 모바일 IPTV의 열화 컨텐츠 평가를 위한 효율적 QoE 인지형 전송 스트림 측정 스키마)

  • Kim, Jin-Sul;Yoon, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.352-360
    • /
    • 2010
  • Supporting user perceptual QoE-guaranteed IP-based multimedia service such as IPTV and Mobile IPTV, we represent an efficient QoE-aware transport stream assessment schemes to apply realtime mobile IPTV's contents distorted by various network errors such as bandwidth, delay, jitter, and packet loss. This paper proposes in detail an efficient matching and QoE-aware measurement methods. The brightness of the digitized contents per each frames of transport streams is used and applied to reduced-reference method. The hybrid video quality metric is designed by QoE-indicators such as blur, block, edge busyness, and color error. We compare original with processed source to evaluate them in a high precision degree of accuracy.