• Title/Summary/Keyword: Realized value

Search Result 428, Processing Time 0.02 seconds

New Technologies for Enhancing Particles Separation Efficiency in Coagulation and Filtration (입자분리효율을 높이기 위한 새로운 기술)

  • Kunio, Ebie;Jang, Il-Hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.254-269
    • /
    • 2004
  • Polysilicato-iron coagulant (PSI) is receiving attention in Japan as a substitute for aluminum-based coagulants. In the first part of this article, coagulation, sedimentation and filtration experiments were carried out using kaolin clay particles as the turbidizing material and four types of PSI with various molar ratios of polysilicic acid to ferric chloride (Si/Fe ratio). Results demonstrate that use of a PSI with a high Si/Fe ratio can cause a more dramatic decrease in treated water turbidity but a higher suction time ratio (STR) than when PACl is used. However, optimization by increasing the rapid agitation strength GR is found to greatly improve the STR. In addition, the series of filtration experiments verified that optimization of GR is greatly effective in controlling rapid increases in filter head loss, and also formation of a thin aging layer in the upper part of the filter bed by slow-start filtration is effective in improving filtered water turbidity over the entire filtration process. The second part of this article describes two innovative filtration techniques to increase the particle separation efficiency; (1) coagulant-coated filter medium by enhancing the electrical potential of the surface of the filter medium, and (2) coagulant dosing in influent by controlling the electrical potential of particles entering the filter layer. From the results of the various filtration experiments using a pilot plant, these two techniques were found to be very effective to reduce the effluent water turbidity from the start to the end of a filter run. Moreover, in the filtration experiments using these two methods simultaneously, higher removal efficiency of approximately 3-log (99.7%) was realized, resulting that the finished water turbidity was accordingly reduced to 0.004mg/L.

The concentration of serum amyloid A and haptoglobin of pigs infected with Aujeszky′s disease virus (오제스키병에 감염된 돼지의 serum amyloid A와 haptoglobin의 농도 변화)

  • 오윤택;조정곤
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.45-52
    • /
    • 2002
  • The acute phase serum protein response is a well-known general indicator of inflammation, trauma or other pathological conditions and its relevance for the monitoring of the health status of domestic animals is being increasingly realized. The changes in serum protein composition which occur after tissue damage represent a part of the systemic response of the injured animals which is mediated by pro-inflammatory cytokines such as TNF-$\alpha$, IL-6 and IL-1. These responses play a vital role in containing the tissue damage and enhancing the processes of repair and resolution. From a clinical perspective, the assay of acute phase proteins can provide a method for detecting inflammation. In animals, the most sensitive acute phase proteins are haptoglogin, serum amyloid A and at-acid glycoprotein in response to inflammatory condition. The aim of this study was to assess the diagnostic value of the concentrations of serum amyloid A(SAA) and haptoglobin(HP) in serum of pigs infected with Aujeszky's disease virus(ADV). Fifty pigs infected with ADV and 5 normal pigs were used in this experiment. The mean serum concentration of Shh of pigs infected with ADV was 96.8 $\pm$ 7.1 $\mu\textrm{g}$/㎖(range, 36.0∼187.5 $\mu\textrm{g}$/㎖) and that of normal pigs was 42.9$\pm$3.3 $\mu\textrm{g}$/㎖(range, 17.3∼127.8 $\mu\textrm{g}$/㎖). The mean serum concentration of HP of pigs infected with ADV was 1,164.4 $\pm$ 96.9 $\mu\textrm{g}$/㎖ (range, 790.2∼l,769.2 $\mu\textrm{g}$/㎖) and that of normal pigs was 675.4 $\pm$ 56.3 $\mu\textrm{g}$/㎖ (range, 650.0-690.4 $\mu\textrm{g}$/㎖). The mean concentrations of SAA and HP in serum of pigs infected with ADV compared with those of normal pigs showed approximately a two-fold. It was concluded that the concentrations of Shh and HP in serum may proved to be diagnostic marker of Aujeszky's disease.

An experimental study on the discharge characteristics of underflow type floating vertical lift gate at free-flow condition (부력식 연직수문의 자유흐름 상태에서 하단방류 특성에 관한 실험적 연구)

  • Han, Il Yeong;Choi, Heung Sik;Lee, Ji Haeng;Ra, Sung Min
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.5
    • /
    • pp.405-415
    • /
    • 2018
  • Hydraulic variables such as discharge coefficient, gate opening, and upstream water depth are required to calculate the discharge of vertical lift gate. It is very important for a precise gate design, because it may affect the rest, to predict the behavior of gate opening during operation. In this study, an equation by which gate opening could be predicted with any upstream water depths was derived from the relation between the calculated value from buoyancy theory and measured one from experiment for a floating gate model. Downpull force was the reason for the differences between the calculated and the measured and it was verified using pressure coefficient. Also, the relation of discharge coefficient with gate opening ratios was derived. The derived relations were used for flood routing and it was realized that downpull force effect should be fully taken into account during gate design.

Design of Optimized Fuzzy Cascade Controller Based on HFCGA for Ball & Beam System (볼빔 시스템에 대한 계층적 공정 경쟁 유전자 알고리즘을 이용한 최적 퍼지 Cascade 제어기 설계)

  • Jang, Han-Jong;Oh, Sung-Kwun;Kim, Hyun-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.391-398
    • /
    • 2009
  • In this study, we introduce the design methodology of an optimized fuzzy cascade controller with the aid of hierarchical fair competition-based genetic algorithm(HFCGA) for ball & beam system. The ball & beam system consists of servo motor, beam and ball, and remains mutually connected in line in itself. The ball & beam system determines the position of ball through the control of a servo motor. The displacement change the position of ball leads to the change of the angle of the beam which determines the position angle of a servo motor. Consequently the displacement change of the position of the moving ball and its ensuing change of the angle of the beam results in the change of the position angle of a servo motor. We introduce the fuzzy cascade controller scheme which consists of the outer(1st) controller and the inner(2nd) controller as two cascaded fuzzy controllers, and auto-tune the control parameters(scaling factors) of each fuzzy controller using HFCGA. The inner controller controls the position of lever arm which corresponds to the position angle of a servo motor and the outer controller decides the set-point value of the inner controller. HFCGA is a kind of parallel genetic algorithms(PGAs), and helps alleviate the premature convergence being generated in conventional genetic algorithms (GAs). For a detailed comparative analysis from the viewpoint of the performance results and the design methodology, the proposed method for the ball & beam system which is realized by the fuzzy cascade controller based on HFCGA, is presented in comparison with the conventional PD cascade controller based on serial genetic algorithms.

Design of a 5.8 GHz Narrow Band-pass Filter with Harmonics Suppression (고조파가 억제된 5.8 GHz 협대역 대역통과 여파기)

  • Yoon, Ki-Cheol;Lee, Jong-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2A
    • /
    • pp.167-173
    • /
    • 2008
  • In this paper, the flexible narrow bandpass filters (BPFs) with ${\lambda}$g/4 short and ${\lambda}$g/2 open stubs by microstrip line on duroid substrate are suggested. These BPFs with narrow bandwidth show flexible bandwidth with variation of the position of the stubs using the Qe (external quality factor) without changing the impedance value at microwave range. On the other hand, by replacing the series quarter-wavelength connecting lines with the equivalent T-shaped line of bandstop filter(BSF), the compact stub bandpass filter with harmonics suppression can be realized. The BPF with ${\lambda}$g/4 short stubs shows the insertion loss of 2.1 dB and the return loss of 18 dB and BPF with ${\lambda}$g/2 open stubs shows the insertion loss of 1.2 dB and the return loss of 21.9 dB at the center frequency of 5.8 GHz and the bandwidth of 10 %.

Improvement of Relative Positioning Accuracy with GPS Carrier Phase Using Multi-Base Station (다중기준국 방식을 이용한 GPS 반송파 상대측위 정확도 향상)

  • Lee, Jae-One
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.6
    • /
    • pp.617-624
    • /
    • 2008
  • In general, RTK-GPS(Real Time Kinematic GPS) based on the single reference station is able to determinate the high accurate position of rover on the spot using error correction information of transmitted carrier phase from the base station via wireless modem. However, single reference station method has some weak points to decrease positioning accuracy because it must be obtained carrier phase from the each satellite continuously, allowed to transmit without obstacle and limited to short base line distance between base and rover station. This paper aims to attempt network based GPS carrier phase differential positioning using three multi reference stations to overcome the method of single reference station and RTK network is realized by real time monitoring program with Visual C++. The optimum error correction value of three multi reference stations by RTK networking is selected automatically to correct the position of rover station. In this paper, this algorithm is applied to determine sea water level using GPS buoy, and the accuracy results of water level change were analyzed and compared with each other using single and multi reference stations.

The Ideologies and the Systems of the Healthy Family Act (건강가정기본법의 이념과 체계)

  • 조희금;박미석
    • Journal of Families and Better Life
    • /
    • v.22 no.5
    • /
    • pp.331-344
    • /
    • 2004
  • Korean society recently realized the needs for a system that may effectively prevent and/or resolve different family problems caused by the rapidly changing modem society. In order to carry out this objectives. The Healthy Family Act has been legislated and is to be enforced from the 1st of January, 2005. Legislating the law is a means to establish an administrative and institutional structure that may bring in the total welfare system centered around family, so as to promote healthy families in our society. This is also a land marking event that has shifted the paradigm from the welfare system focusing on individual protection to the total welfare system based upon family units. Hence, this study is to examine the specific concepts of 'healthy family,' which is the goal of The Healthy Family Act, and thus to propose the objectives of the law by analysing the institutional system of it. The Healthy Family Act, which consists of major 37 items of 5 chapters with supplementary provisions, aims at the five ideals as follows. The first is to promote the healthy family which is the basis of individual welfare and well-to-do society. The second is to emphasize the importance of family and to provide total service system for family unit. The third is to establish the family value which supports gender-equality and democracy. The fourth is to reinforce the governmental support for independence and cooperation of family. And the fifth is to promote the in-advance and precautionary support for family problems. The law also includes administrative methods for Strong Families Center, different projects and programs for promoting healthy families, roles of Healthy Family Specialist and means to cultivating them, and the policies to specifically carry out the ideas of the law. It is now important to recognize that the development of nation is based on the healthy families and to put much effort in carrying out the ideas and goals of The Healthy Family Act.

Progress in R&D of coated conductor in M-PACC project

  • Izumi, T.;Ibi, A.;Nakaoka, K.;Taneda, T.;Yoshida, T.;Takagi, Y.;Nakamura, T.;Machi, T.;Katayama, K.;Sakai, N.;Yoshizumi, M.;Koizumi, T.;Kimura, K.;Kato, T.;Kiss, T.;Shiohara, Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • The five-year national project in Japan for R&D of coated conductors and applications, named as the Materials and Power Applications of Coated Conductors (M-PACC) project, was finished at the end of FY2013. The project consists of four sub-themes as cable, transformer, SMES and coated conductors. In the theme of coated conductors, the fabrication process had been developed to satisfy the requirements from the applications such as in-field $I_c$ performance, low AC loss in the long tapes etc. Through the project, the remarkable progress was achieved as follows; a high in-field minimum $I_c$ value over 54A/cm-width under 3T at 77K was realized in a 200m long EuBCO tape with artificial pinning centers of $BaHfO_3$ by the pulsed laser deposition (PLD) technique on the IBAD template. On the other hand, the AC loss reduction was confirmed in the tapes fabricated by both PLD and the metal organic deposition (MOD) techniques by scribing 100m tapes into 10-filamments. Additionally, the mechanism of the delamination phenomenon was systematically investigated and the strength was improved by eliminating the origins of the weak points in the films. Through the development, all targeted goals were accomplished and the several results were appreciated as a world champion data.

A Study on the Improvement of the Criteria for the Management Evaluation Related to the Means-Efficiency of Public Library (공공도서관 수단효율성관련 경영평가기준의 개선방향에 관한 연구)

  • Jung, Won Joo;Hong, Hyun Jin
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.28 no.4
    • /
    • pp.203-221
    • /
    • 2017
  • This study is to suggest some improvement directions of the criteria for the management evaluation in order to contribute to the achievement of lasting value of the continuous development and publicity in regard to the public library means-efficiency. To this end, This study analyzed the means-efficiency evaluation criteria via theoretical review on business analysis of private enterprise and the analysis framework based on it. The improvement of evaluation criteria in regard to efficiency for the continuous development of public library are as follows. 1) Regardless of domestic and foreign, an efficiency index in the performance evaluation index of public library is absolutely insufficient. The sufficient indexes measuring efficiency which is appropriate for the concept of performance should be developed. 2) A flow data representing input and performance in certain time period is insufficient. Therefore, evaluation index consisted of flow data should be more developed. 3) Long term stock data is excluded in the term cost as it is the cost used for the long term such as fixed assets. However, it is useful as input data, which is realized through the perfect accounting.

Design of a Dual-Band Loop-Type Ground Antenna Using Lumped-Elements (집중 소자를 사용한 이중 대역 루프형 그라운드 안테나 설계)

  • Lee, Hyung-Jin;Liu, Yang;Lee, Jae-Seok;Kim, Hyung-Hoon;Kim, Hyeong-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.551-558
    • /
    • 2012
  • This paper presents a dual band loop-type ground antenna using lumped-elements that control the impedance bandwidth and resonant frequency. The dual-band operation of the proposed antenna is realized by inserting an additional resonated loop feed structure into the reference ground antenna. As the proper value of the capacitor and the inductor are chosen, the impedance bandwidth of our antenna with voltage standing wave ratio(VSWR) equal to 3 is 85 MHz and 725 MHz at the 2.45 and 5.5 GHz frequency band, respectively. Its validity is demonstrated via both the computed and measured results. Good antenna patterns and efficiencies are achieved at the dual frequency bands, as well as the physically small antenna element size($10{\times}5mm^2$).