Doh, Il;Joe, Daniel J.;Kim, Sung Mok;Baik, Kyung Min;Kim, Yong Tae;Park, Seung Min
Journal of Biomedical Engineering Research
/
v.43
no.3
/
pp.147-152
/
2022
This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.
Purpose: This study investigated the effects of visual feedback during abdominal hollowing (AH) in four point kneeling position, using real-time ultrasound imaging through measurement of the changes in the thickness of transversus abdominis (TrA), internal abdominal oblique (IO), and external abdominal oblique (EO). Methods: The subjects of this study were 32 healthy males who were divided intothe experimental group of 16 subjects and the control group of 16 subjects. The real-time ultrasound feedback was applied to the experimental group while they were educated on the AH exercise in four point kneeling whereas only general education and training were given to the control group. After the training, the changes in the thickness of abdominal muscles during AH in four point kneeling were compared between the experimental group and the control group. Results: The differences of the changes in the thickness of TrA and EO between the two groups were statistically significant. Conclusion: The experimental group experienced a higher increase in the thickness of TrA than the control group while the thickness of IO and EO of the experimental.
Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Lee, Jea-Jung;Kim, Won-Tae;Lee, Bo-Young
Journal of the Korean Society for Nondestructive Testing
/
v.32
no.3
/
pp.284-290
/
2012
Infrared thermography uses infrared energy radiated from any objects above absolute zero temperature, and the range of its application has been constantly broadened. As one of the active test techniques detecting radiant energy generated when energy is applied to an object, ultrasound infrared thermography is a method of detecting defects through hot spots occurring at a defect area when 15~100 kHz of ultrasound is excited to an object. This technique is effective in detecting a wide range affected by ultrasound and vibration in real time. Especially, it is really effective when a defect area is minute. Therefore, this study conducted thermography through lock-in signal processing when an actual defect exists inside the austenite STS304 seamless pipe, which simulates thermal fatigue cracks in a nuclear power plant pipe. With ultrasound excited, this study could detect defects on the rear of a pipe by using an aluminium reflector. Besides, by regulating the angle of the aluminium reflector, this study could detect both front and rear defects as a single infrared thermography image.
We have proposed an indoor positioning system for moving objects and/for the blind or visually impaired to play various sports. [ for a blind or visually impaired playing various sports.] This system consists of a wireless heart rate monitor, wireless sensor network and / 4 ultrasound satellites [ configuration with four ultrasound satellite modules) at the corners of the room. This system provides / the real-time measurement of the location and heart rate of the person in the room[ non-invasive measurement method of the heart rate and the location of a person in real time ], and will help the [a] blind or visually impaired enjoy sports more easily.
Ultrasound images are noninvasive, can be observed in real time, have no radiation exposure, do not cause pain, and are not restricted in use depending on the patient's prosthetic implant or medical condition. Since the use of ultrasound in the dental field was first applied for tooth preparation in 1957, the use of diagnostic ultrasound for the first time in 1963 has been reported. Currently, it is used in the diagnosis of soft tissue lesions such as malignant tumor or salivary gland disease, fine needle aspiration test, temporomandibular joint disease, lymph node metastasis, measurement of muscle thickness and inflammatory diseases, differentiation of periapical cyst and granulation tissue, measurement of periodontal tissue thickness. The ultrasound image can be visualized in real time. The clinician can explain the structure to the patient while consulting the patient and consult the patient. When injecting the drug into a specific site or aspirating a specific site or substance, So that it can be confirmed and practiced. Recently, ultrasonic equipment specialized in the dental field has been developed and marketed, and it is expected that the use of ultrasonic waves will become active in the dentistry. In the future, development of popular equipment with size and frequency suitable for dental diagnosis and various researches on maxillofacial ultrasonic anatomy. If clinical studies are continuously carried out to demonstrate efficacy, ultrasound is expected to aid in accurate diagnosis and treatment throughout the dentistry.
The present study was undertaken to evaluate the accuracy of ultrasonography in early pregnancy diagnosis in goats. Ultrasonographic scanning with real time B-mode ultrasound machine having 5 MHz linear array transducer was performed on gravid uterus (n=24) obtained from slaughterhouse (Group I). Crown rump length (CRL) measured by ultrasound was found significantly different (p<0.05) with actual CRL measured after dissection in early pregnancy. However, age predicted by ultrasound through the measurement of CRL was found highly correlated (r=0.92) with age measured after dissection through CRL and the weight of fetus. Ages predicted by ultrasound through the measurement of trunk diameter (TD) and uterine diameter (UD) and ages measured after dissection were found highly and equally correlated (r=0.98) and did not differ significantly. Data from six does synchronized (Group II) with PGF2$\alpha$ (Estrumate) at 11 days apart were collected through ultrasound from 17 to 42 days post breding. The correlation between CRL and gestational age was high (r=0.97) in day 30 to 42 post breeding. A high coefficient of correlation (r=0.98) was also observed between predicated age by ultrasound and actual age calculated after kidding. The correlation between CRL and gestational age by the formula Y=(a+bX) i.e. Y=24.42+0.39 X where Y=gestational age and X=CRL, was recorded very high (r=0.99). Accuracy of ultrasonography was lowest on day 17 to 19 (66%) and reached 100% on day 34. Data from 30 does (group III) randomly subjected to only one time ultrasounds scanning to assess the accuracy of pregnancy diagnosis were also obtained. Ages predicted by TD and UD measurements were observed to be non-significantly different with actual age obtained after kidding and correlation between ages predicted by TD and UD measurement with actual age after kidding was found equally and highly correlated (r=0.98). The operator's accuracy in the whole experiment including all three groups was found to be 92%. The sensitivity was 93% and specificity was 86%. From the present study, it was observed that CRL was the most reliable parameter to find out gestational age in early pregnancy and the new formula derived was found very accurate to find out gestational age. TD and UD were also found to be equally reliable parameter to find out gestational age in mid and late stage of pregnancy through ultrasonography. It was concluded that ultrasonography by real time B mode with 5 MHz transrectal transducer was found to be reliable, safe and accurate and practicable means in diagnosing early pregnancy diagnosis as early as 25 days post breeding.
Hwang, Jeong Mi;Cheong, Jae Kyoung;Kim, Sam Su;Jung, Bong Hwan;Koh, Myung Jae;Kim, Hyeong Cheol;Choy, Yun Ho
Asian-Australasian Journal of Animal Sciences
/
v.27
no.4
/
pp.457-463
/
2014
Ultrasound measurements of backfat thickness (UBF), longissimus muscle area (ULMA) and marbling score (UMS) and carcass measurements of carcass weight (CW), backfat thickness (BF), longissimus muscle area (LMA), and marbling score (MS) on 7,044 Hanwoo steers were analyzed to estimate genetic parameters. Data from Hanwoo steers that were raised, finished in Hoengseong-gun, Gangwon-do (province) and shipped to slaughter houses during the period from October 2010 to April 2013 were evaluated. Ultrasound measurements were taken at approximately three months before slaughter by an experienced operator using a B-mode real-time ultrasound device (HS-2000, FHK Co. Ltd., Tokyo, Japan) with a 3.5 MHz linear probe. Ultrasound scanning was on the left side between 13th rib and the first lumbar vertebrae. All slaughtering processes and carcass evaluations were performed in accordance with the guidelines of beef grading system of Korea. To estimate genetic parameters, multiple trait animal models were applied. Fixed effects included in the models were: the effects of farm, contemporary group effects (year-season at the time of ultrasound scanning in the models for UBF, ULMA, and UMS, and year-season at slaughter in the models for CW, BF, LMA, and MS), the effects of ultrasound technicians as class variables and the effects of the age in days at ultrasound scanning or at slaughtering as linear covariates, respectively for ultrasound and carcass measures. Heritability estimates obtained from our analyses were 0.37 for UBF, 0.13 for ULMA, 0.27 for UMS, 0.44 for CW, 0.33 for BF, 0.36 for LMA and 0.54 MS, respectively. Genetic correlations were strongly positive between corresponding traits of ultrasound and carcass measures. Genetic correlation coefficient between UBF and BF estimate was 0.938, between ULMA and LMA was 0.767 and between UMS and MS was 0.925. These results suggest that ultrasound measurement traits are genetically similar to carcass measurement traits.
Journal of the Korean Society for Precision Engineering
/
v.22
no.8
s.173
/
pp.182-191
/
2005
It is very important to obtain a high quality of bone image for an accurate ultrasonic measurement of bone mineral density. In this study, we suggested a technique to acquire an optimal image by adapting an acoustic lens and a properly selected ultrasonic probe. Also, we have applied an image processing algorithm with which automatically makes a decision of brightness and contrast of image by generating threshold level, a composition of ultrasonic data, an elimination of noise using modified median filter, and a real time interpolation. We could confirm much improved resolution of bone image with acoustic lens attached to the ultrasonic probe and with the image processing algorithm suggested in this study. Therefore, it became possible to precisely diagnose the osteoprosis using ultrasonic imaging technique.
This study is conducted to use the real-time ultrasound measurement data of Hanwoo as basic data being available to improvement. We used the ultrasound measurement data of 1,125 heads of performance tested cattle and the carcass data after castrating at about 12 months of age, fattened to 30 months, and then sold. For 921 heads of progeny tested cattle, we used test data and slaughter data. Heritabilities of ultrasound data for longissimus muscle area and backfat thickness measured at 12 months of age were estimated as 0.57 and- 0.41, respectively, and at 24 months of age, it was 0.57 and- 0.60, respectively, with high heritability. However, in estimation value of heritability containing ultrasound measurement for percent intramuscular fat, it showed low and medium heritability as 0.14 at 12 months of age and 0.22 at 24 months of age for each. The longissimus muscle area, backfat thickness, and percent intramuscular fat of ultrasound measure traits and longissimus muscle area, backfat thickness, marbling score of carcass traits genetic correlation of at 12 months of age were estimated as 0.616, 0.544, 0.501, respectively and at 24 months of age, it showed high genetic correlation as 0.894, 0.937, 0.263, respectively. As a result of ranking correlation between selection index by using weight, carcass traits at 12 months of age and selection index based on ultrasound measurement data which has high genetic correlation, in data of ultrasound measurement at 12 months of age, it showed high ranking correlation as that selection index of young bull was 0.140 and that of proven bull was 0.843.
Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.