• Title/Summary/Keyword: Real-time imaging

Search Result 536, Processing Time 0.03 seconds

Three-dimensional display based on integral imaging

  • Lee, Byoung-Ho;Park, Jae-Hyeung;Kim, Yun-Hee;Choi, Hee-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.36-40
    • /
    • 2005
  • Integral imaging is an attractive three-dimensional display technique providing full-parallax full-color three-dimensional images in real-time without any viewing aids. In this paper, we present the recent progress on the three-dimensional display based on integral imaging focusing on its depth and viewing angle enhancement and the three-dimension/twodimension convertibility.

  • PDF

Computer-generated integral imaging system used in virtual reality (가상현실에 이용할 수 있는 컴퓨터 생성 집적 영상 시스템)

  • Seok, Myeong-Hun;Min, Seong-Uk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.07a
    • /
    • pp.158-159
    • /
    • 2005
  • Three-dimensional(3D) integral imaging system which can be used in a virtual reality system is proposed. The proposed system uses a new image mapping algorithm which can achieve the real time processing, which is indispensable for the virtual reality system. 3D images generated by the advanced graphic software such as OpenGL API can be directly used without complex adaptation. Therefore, the computer-generated integral imaging system using the proposed mapping algorithm can be successfully applied to virtual reality.

  • PDF

Design of MRI Spectrometer Using 1 Giga-FLOPS DSP (1-GFLOPS DSP를 이용한 자기공명영상 스펙트로미터 설계)

  • 김휴정;고광혁;이상철;정민영;장경섭;이동훈;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • Purpose : In order to overcome limitations in the existing conventional spectrometer, a new spectrometer with advanced functionalities is designed and implemented. Materials and Methods : We designed a spectrometer using the TMS320C6701 DSP capable of 1 giga floating point operations per second (GFLOPS). The spectrometer can generate continuously varying complicate gradient waveforms by real-time calculation, and select image plane interactively. The designed spectrometer is composed of two parts: one is DSP-based digital control part, and the other is analog part generating gradient and RF waveforms, and performing demodulation of the received RF signal. Each recover board can measure 4 channel FID signals simultaneously for parallel imaging, and provides fast reconstruction using the high speed DSP. Results : The developed spectrometer was installed on a 1.5 Tesla whole body MRI system, and performance was tested by various methods. The accurate phase control required in digital modulation and demodulation was tested, and multi-channel acquisition was examined with phase-array coil imaging. Superior image quality is obtained by the developed spectrometer compared to existing commercial spectrometer especially in the fast spin echo images. Conclusion : Interactive control of the selection planes and real-time generation of gradient waveforms are important functions required for advanced imaging such as spiral scan cardiac imaging. Multi-channel acquisition is also highly demanding for parallel imaging. In this paper a spectrometer having such functionalities is designed and developed using the TMS320C6701 DSP having 1 GFLOPS computational power. Accurate phase control was achieved by the digital modulation and demodulation techniques. Superior image qualities are obtained by the developed spectrometer for various imaging techniques including FSE, GE, and angiography compared to those obtained by the existing commercial spectrometer.

  • PDF

Development of Geometrical Quality Control Real-time Analysis Program using an Electronic Portal Imaging (전자포탈영상을 이용한 기하학적 정도관리 실시간 분석 프로그램의 개발)

  • Lee, Sang-Rok;Jung, Kyung-Yong;Jang, Min-Sun;Lee, Byung-Gu;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.77-84
    • /
    • 2012
  • Purpose: To develop a geometrical quality control real-time analysis program using an electronic portal imaging to replace film evaluation method. Materials and Methods: A geometrical quality control item was established with the Eclipse treatment planning system (Version 8.1, Varian, USA) after the Electronic Portal Imaging Device (EPID) took care of the problems occurring from the fixed substructure of the linear accelerator (CL-iX, Varian, USA). Electronic portal image (single exposure before plan) was created at the treatment room's 4DTC (Version 10.2, Varian, USA) and a beam was irradiated in accordance with each item. The gaining the entire electronic portal imaging at the Off-line review and was evaluated by a self-developed geometrical quality control real-time analysis program. As for evaluation methods, the intra-fraction error was analyzed by executing 5 times in a row under identical conditions and procedures on the same day, and in order to confirm the infer-fraction error, it was executed for 10 days under identical conditions of all procedures and was compared with the film evaluation method using an Iso-align$^{TM}$ quality control device. Measurement and analysis time was measured by sorting the time into from the device setup to data achievement and the time amount after the time until the completion of analysis and the convenience of the users and execution processes were compared. Results: The intra-fraction error values for each average 0.1, 0.2, 0.3, 0.2 mm at light-radiation field coincidence, collimator rotation axis, couch rotation axis and gantry rotation axis. By checking the infer-fraction error through 10 days of continuous quality control, the error values obtained were average 1.7, 1.4, 0.7, 1.1 mm for each item. Also, the measurement times were average 36 minutes, 15 minutes for the film evaluation method and electronic portal imaging system, and the analysis times were average 30 minutes, 22 minutes. Conclusion: When conducting a geometrical quality control using an electronic portal imaging, it was found that it is efficient as a quality control tool. It not only reduces costs through not using films, but also reduces the measurement and analysis time which enhances user convenience and can improve the execution process by leaving out film developing procedures etc. Also, images done with evaluation from the self-developed geometrical quality control real-time analysis program, data processing is capable which supports the storage of information.

  • PDF

Muscle Functional MRI of Exercise-Induced Rotator Cuff Muscles

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • The aim of this study was to provide a new assessment of rotator cuff muscle activity. Eight male subjects (24.7 ± 3.2 years old,171.2 ± 9.8 cm tall, and weighing 63.8 ± 11.9 kg) performed the study exercises. The subjects performed 10 sets of the exercise while fixing the elbow at 90 degrees flexure and lying supine on a bed. One exercise set consisted of the subject performing external shoulder rotation 50 times using training equipment. Two imaging protocols were employed: (a) true fast imaging with steady precession (TrueFISP) at an acquisition time of 12 seconds and (b) multi-shot spin-echo echo-planar imaging (MSSE-EPI) at an acquisition time of 30 seconds for one echo. The main method of assessing rotator cuff muscle activity was functional T2 mapping using ultrafast imaging (fast-acquired muscle functional MRI [fast-mfMRI]). Fast-mfMRI enabled real-time imaging for the identification and evaluation of the degree of muscle activity induced by the exercise. Regions of interest were set at several places in the musculus subscapularis (sub), musculus supraspinatus (sup), musculus teres minor (ter), and deltoid muscle (del). We used the MR signal of the images and transverse relaxation time (T2) for comparison. Most of the TrueFISP signal was not changed by exercise and there was no significant difference from the resting values. Only the T2 in the musculus teres minor was increased after one set and the change were seen on the T2 images. Additionally, except for those after one and two sets, the changes in T2 were significant compared to those at rest (P < 0.01). We also demonstrated identify and visualize the extent to which muscles involved in muscle activity by exercise. In addition, we showed that muscle activity in a region such as a shoulder, which is susceptible to B0 inhomogeneity, could be easily detected using this technique.

Development of Real-time Screening System for Superior Melon Seeds Using Optical Coherence Tomography (광간섭 단층촬영법을 이용한 우량 참외 종자 실시간 감별 시스템 개발)

  • Han, Seunghoon;Lee, Changho;Lee, Seung-Yeol;Jung, Hee-Young;Kim, Jeehyun
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.262-267
    • /
    • 2013
  • We developed a real-time screening system using optical coherence tomography (OCT) to distinguish the fruitful melon seeds efficiently. Cross-section images of melon seeds infected with Cucumber green mottle mosaic virus (CGMMV) showed an additional layer that did not appear in normal seeds. Additional layer appeared under $100{\sim}300{\mu}m$ from the surface of the seed. OCT can visualize the micro-structural and morphological changes of the internal seed structure. Real-time OCT seed screening system provided the real-time, non-destructive, cross-section image and quantitative information such as A-scan analysis of selected region in the cross-section image. We can distinguish the viral infection seeds while monitoring the averaged A-scan analysis graph in real-time by considering the second peak value of the graph which refers to the layer that occurred owing to the virus. Real-time OCT seed screening system could assist to distinguish the disease caused by CGMMV.

Real-time passive millimeter wave image segmentation for concealed object detection (은닉 물체 검출을 위한 실시간 수동형 밀리미터파 영상 분할)

  • Lee, Dong-Su;Yeom, Seok-Won;Lee, Mun-Kyo;Jung, Sang-Won;Chang, Yu-Shin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.2C
    • /
    • pp.181-187
    • /
    • 2012
  • Millimeter wave (MMW) readily penetrates fabrics, thus it can be used to detect objects concealed under clothing. A passive MMW imaging system can operate as a stand-off type sensor that scans people in both indoors and outdoors. However, because of the diffraction limit and low signal level, the imaging system often suffers from low image quality. Therefore, suitable statistical analysis and computational processing would be required for automatic analysis of the images. In this paper, a real-time concealed object detection is addressed by means of the multi-level segmentation. The histogram of the image is modeled with a Gaussian mixture distribution, and hidden object areas are segmented by a multi-level scheme involving $k$-means, the expectation-maximization algorithm, and a decision rule. The complete algorithm has been implemented in C++ environments on a standard computer for a real-time process. Experimental and simulation results confirm that the implemented system can achieve the real-time detection of concealed objects.

Real-Time Compressed Video Acquisition System for Stereo 360 VR (Stereo 360 VR을 위한 실시간 압축 영상 획득 시스템)

  • Choi, Minsu;Paik, Joonki
    • Journal of Broadcast Engineering
    • /
    • v.24 no.6
    • /
    • pp.965-973
    • /
    • 2019
  • In this paper, Stereo 4K@60fps 360 VR real-time video capture system which consists of video stream capture, video encoding and stitching module is been designed. The system captures stereo 4K@60fps 360 VR video by stitching 6 of 2K@60fps stream which are captured through HDMI interface from 6 cameras in real-time. In video capture phase, video is captured from each camera using multi-thread in real-time. In video encoding phase, raw frame memory transmission and parallel encoding are used to reduce the resource usage in data transmission between video capture and video stitching modules. In video stitching phase, Real-time stitching is secured by stitching calibration preprocessing.

Implementation of an improved real-time object tracking algorithm using brightness feature information and color information of object

  • Kim, Hyung-Hoon;Cho, Jeong-Ran
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.5
    • /
    • pp.21-28
    • /
    • 2017
  • As technology related to digital imaging equipment is developed and generalized, digital imaging system is used for various purposes in fields of society. The object tracking technology from digital image data in real time is one of the core technologies required in various fields such as security system and robot system. Among the existing object tracking technologies, cam shift technology is a technique of tracking an object using color information of an object. Recently, digital image data using infrared camera functions are widely used due to various demands of digital image equipment. However, the existing cam shift method can not track objects in image data without color information. Our proposed tracking algorithm tracks the object by analyzing the color if valid color information exists in the digital image data, otherwise it generates the lightness feature information and tracks the object through it. The brightness feature information is generated from the ratio information of the width and the height of the area divided by the brightness. Experimental results shows that our tracking algorithm can track objects in real time not only in general image data including color information but also in image data captured by an infrared camera.

Development of Near Infrared Radiation Image Board for Performace Improvement of Grain Sorter (곡물선별기의 선별력 향상을 위한 근거리적외선 영상보드 개발)

  • Lee, Chae-Wook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.1
    • /
    • pp.25-30
    • /
    • 2017
  • Currently, most of the grain sorter uses CCD optic camera to find defective products. The aim of this paper is to use the CCD camera, and aim for improving the sorting power of the grain separator by using NIR(Near Infrared Radiation) sensor based on moisture content measurement algorithm. We intend to develop a system to develop an NFC imaging system in real time by developing an NIR imaging system and developing the grain sorter system that is considered to be defective in real time by checking the internal moisture content of the raw material in the real time.

  • PDF