• Title/Summary/Keyword: Real-Bridge

Search Result 577, Processing Time 0.034 seconds

Experimental Study of Anchor Zone of Externally Prestressed Segmental Bridge (현장 실험을 통한 상판분절 P.C 교량의 정착부 응력 분석)

  • 이성우;배두병;지기환;정남석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.87-94
    • /
    • 1994
  • During the construction of externally prestressed 7-span continuous segmental bridge, cracks beyond permissible limit were found at anchor zone of expansion joint segment. To eliminate this problem, tension side of diaphragm was prestressed by post-tensioning bars in vertical and horizontal direction. To investigate this remedy is acceptable, stresses of reinforcing bars and concrete surface were measured for the real structure in the field. The measurement was performed through each step of prestressing sequence during construction. Also to investigage stresses induced by live load, static load test was performed and the results was analyzed. In this paper it will be presented the procedure and results for this experimental study along with comparison with analytical study.

  • PDF

A Base Study on Health Monitoring System of Ubiquitous Intelligent Bridge (유비쿼터스 지능형 교량의 계측 시스템 기초 연구)

  • Jo, Byung-Wan;Kim, Heoun;Park, Jung-Hoon;Yoon, Kwang-Won;Choi, Hae-Yun;Chang, Jeong-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.544-547
    • /
    • 2008
  • In 1990, Korea building contractors were indifferent maintenance management cause focus on completion of construction before construction collapsed. Currently, structures monitoring systems are restrictive on large structures. Structures monitoring systems are limited many old and small structures in the whole nation. Recently, we make efforts application Ubiquitous technology as like sensor, sensor network system, and wireless communication system in construction. This paper applies bridge management system using Ubiquitous skill which is real-time monitoring report offering system.

  • PDF

Vibration Characteristic Analysis of Bridge Simulator by Pulse ESPI System (Pulse ESPI System을 이용한 모형교량의 진동특성해석)

  • Choi JK;Kim K.S.;Jang H.S.;Kang M.G.;Kim S.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1433-1437
    • /
    • 2005
  • Until now, strain gage technique and accelerometer for the diagnosis safety of constructions are used widely. However, the limits of these methods are revealed. But Electronic Speckle Pattern Interferometry(ESPI) that uses Pulse Laser is noncontact, whole-field, real-time measuring method also dull to disturbance and can achieve test result in a very short time. It has various strong point in spot application, swift establishment, and dynamic conduct analysis for the entire field of Laser illuminate. This author analyzed vibration characteristic of using the Pulse ESPI System, the diagnosis safety of bridges, to simplify the analysis of the dynamic conduct of a large construction.

  • PDF

Analysis of the Three Phase Inductor-Converter Bridge Circuit by Means of State-Space Averaging Method (상태변수평균화법에 의한 삼상ICB회로 해석)

  • Park, Min-Ho;Hong, Soon-Chan;Oh, Soo-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.394-398
    • /
    • 1988
  • In this paper, the time-averaged behavior of the three-phase Inductor-Converter Bridge (ICB) circuit has been analyzed by using the state-space averaging method. The results are in closed form far from the results obtained by using the Fourier series. Therefore, the computational difficulties of the infinite Fourier series can be avoided and the results derived in this paper are available especially in real time control. Unlike the SFC, $S^{4}LCL$, DFC and other circuits which have time varying switching intervals for a constant time-averaged value of coil voltage, the ICB circuits operate with a clock-driven sequence of gate pulses which have constant switching intervals.

  • PDF

A Vision-based Damage Detection for Bridge Cables (교량케이블 영상기반 손상탐지)

  • Ho, Hoai-Nam;Lee, Jong-Jae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.39-39
    • /
    • 2011
  • This study presents an effective vision-based system for cable bridge damage detection. In theory, cable bridges need to be inspected the outer as well as the inner part. Starting from August 2010, a new research project supported by Korea Ministry of Land, Transportation Maritime Affairs(MLTM) was initiated focusing on the damage detection of cable system. In this study, only the surface damage detection algorithm based on a vision-based system will be focused on, an overview of the vision-based cable damage detection is given in Fig. 1. Basically, the algorithm combines the image enhancement technique with principal component analysis(PCA) to detect damage on cable surfaces. In more detail, the input image from a camera is processed with image enhancement technique to improve image quality, and then it is projected into PCA sub-space. Finally, the Mahalanobis square distance is used for pattern recognition. The algorithm was verified through laboratory tests on three types of cable surface. The algorithm gave very good results, and the next step of this study is to implement the algorithm for real cable bridges.

  • PDF

Development of a Vision-based Crack Detection Algorithm for Bridge Inspection (교량점검을 위한 비전 기반의 균열검출 알고리즘 개발)

  • Kim, Jin-Oh;Park, Dong-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.642-646
    • /
    • 2008
  • We have developed a vision based crack detection system and algorithm to inspect base side of bridges. After human operator decides from vision images captured if lines on base side are cracks or dirt, our algorithm finds automatically the length, the width and the shape of cracks. The system has been tested with a robot extender on a truck in real environment and has been proved to be very useful to reduce inspection cost as well as the data management.

Effective Approaches for Structural Health Monitoring of Bridges (교량의 건전성 모니터링을 위한 효율적인 접근방법)

  • Jong-Jae, Lee;Chung-Bang, Yun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.135-142
    • /
    • 2004
  • Two-step identification approach for effective bridge health monitoring is proposed to alleviate the issues associated with many unknown parameters faced in the real structures and to improve the accuracy in the estimate results. It is suitable for on-line monitoring scheme, since the damage assessment is not always needed to be carried out whereas the alarming for damages is to be continuously monitored. In the first step for screening potential damaged members, damage indicator method based on modal strain energy, probabilistic neural networks and the conventional neural networks using grouping technique are used and then the conventional neural network technique is utilized for damage assessment on the screened members in the second step. The proposed methods are verified through a field test on the northern-most span of old Hannam Grand Bridge.

  • PDF

Analysis of Hydraulic Characteristics Depending Upon the Geometrical and Discharge Condition at Channel Junctions (하도 합류부의 기하학적 특성과 유량조건에 따른 수리학적 특성 해석)

  • Ahn, Seung-Seop;Choi, Soo-Chul;Yim, Dong-Hee
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.495-503
    • /
    • 2007
  • In this study, we took the geometrical character of the river channel junction and hydrologic conditions as independent variables, and hydraulic behavior characteristics as an independent variable. The result, after multiple analysis was carried out, proved that, except for the generating area of the accelerating zone of velocity the accelerating zone and both the main channel and the tributary zone of stagnation the stagnation zone, there was correlation of over 90%. Also, derived presumed expression of the hydraulic characteristics of the junction was applied to the real natural channel - the river channel of the Guem-ho main channel(the A-yang bridge to the Guem-ho bridge). As the result, it proved that it represented hydraulic characteristics relatively well.

A Study on the Development of high strength concrete for Long Span PC Beam Bridge (장경간 PC Beam 교량을 위한 고강도콘크리트의 개발에 관한 연구)

  • 백상현;이형준;김기수;엄태선;정원기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.141-146
    • /
    • 1998
  • In the present study, we have developed high strength concrete which is adequate for the long span PC beam above 40 meters. We have selected the most adequate materials for high strength concrete through laboratory tests and in-situ mock-up applications. We verified and decided the best curing condition of high strength concrete, and suggests the optimum mix design of high strength concrete. In the future, we will verify the properties-fresh and hardened concrete- of high strength concrete and its serviceability, and also apply the high strength concrete to newly-constructed real bridge structure.

  • PDF

A Study on the Fatigue Strength Evaluation in Rail-type Expansion Joint Weldment of Bridge (레일형 교량신축이음장치 용접부의 피로강도 평가에 관한 연구)

  • 이용복
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.115-120
    • /
    • 1998
  • This paper is especially concerned with the weldment between support beam and square bar that plays important roles in control box of Expansion Joint as a bridge structure. Fatigue strength of the weldment is dependent on notch radius from welding defects and material properties. From which, tensile strength($\sigma$ult) and fatigue notch factor(Kf) become important factors to predict fatigue life. The fatigue notch sensitivity(η) for metals can be divided into two types : high and low notch sensitivity. In this work, the Expansion Joint weldment was found to have low notch sensitivity. Fatigue test of real structure was performed up to 106cycles to be compared with predicted endurance limit.

  • PDF