• Title/Summary/Keyword: Real time discharge

Search Result 234, Processing Time 0.031 seconds

Analysis of the estuary outflow characteristics of floating debris in the downstream of Nakdong River using satellite location tracking buoys (위성 위치 추적 부이를 활용한 낙동강 하류 부유쓰레기의 하구 유출 특성 분석)

  • Jang, Seon-Woong;Yoon, Hong-Joo;Seo, Won-Chan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.2
    • /
    • pp.157-164
    • /
    • 2015
  • The present study is to identify discharge characteristic from the mouth of floating debris in the Nakdong River through real time tracking of moving route and by analyzing hydrometeorologic environmental. To identify the path and route of outflow through the mouth of the river of floating debris, small-sized buoy equipped with satellite location transmitters was used. Moreover, to identify hydrometeorologic environmental, flux of the river, change of discharge of the River-Mouth Weir and wind direction of the mouth of the river area were analyzed. From now on, the present study is expected to be utilized as basic data to identify damage and flowing into nearby ocean of the floating debris of Nakdong River in time of severe rain storm.

A Preliminary Study for Expending of Hospital-Based Home Health Care Coverage - Focused on Car Accident Inpatients Who has the Compensation Insurance - (병원중심 가정간호관리대상 범위 확대를 위한 기초연구(II) - 자동차보험가입 입원환자를 대상으로 -)

  • Park, Eun-Sook;Lee, Sook-Ja;Park, Young-Ju;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.7 no.1
    • /
    • pp.58-72
    • /
    • 2000
  • This study was an attempt to encourage the development of a rehabilitation delivery system and programs as a substitute service for hospitalization on the case of car accident patients, such as hospital based home health care nursing services. Various substitute services for hospitalization are required to curtail the length of stay for inpatients who were hospitalized with car accident compensation insurance. It focused on developing an estimation an early discharge day for car accident inpatients based on detailed statements of treatment for 111 inpatients who were hospitalized at the General Hospital in 1997. This study had four specific purposes as follows. First. to find out the utilization of medical services. Second, to estimate the time of early discharge and income increasing effect based on early discharge for those patients. Third, to identify the factors affecting total medical expenditure and the length of stay for those inpatients. Forth, to figure out the need of utilizing home health care nursing service for accident patients. In order to analyze the length of stay and medical expenditure for inpatients who were hospitalized due to car accidents, the authors conducted micro- and macro-analysis of medical and medical expenditure records. Micro-analysis was done by nominal group discussion of 4 expertise with the critical criteria, such as a decrease in the amount of treatment after surgery, treatments, tests, drugs and changes in the test consistency, drug methods, vital signs, start of ROM exercise, doctor's order, patient's outside visiting ability, and stable conditions. In addition to identifying variables affecting medical expenditure, and the length of stay and income effect due to early discharge day, the data was analyzed with a multiple regression analysis and linear regression analysis model by SPSS-PC for windows and Excell program. Results of this study were as follows. First. the mean length of stay was 50.3 days. whereas the mean length of stay due to early discharge was 34.3 days at the hospital. The estimation of time of early discharge depended on the length of stay. The longer the length of stay, the longer the length of time of early discharge : for instance a length of stay under 10 days was estimated as correlating to a mean length of stay of 6.6 days and early discharge of 6.5. The mean length of stay was 217.4 days and the time of early discharge was 110.1 respectively. The mean medical expenditure per day was found to be 169.085 Won and the mean medical expenditure per day showed negative linear trends according to the length of stay at the hospital. The estimation results of the income effect due to being discharged 16 days early was around 2,244,000 won per bed. However. this sum does not represent the real benefits resulting from early discharge, but rather the income increasing amount without considering medical prime cost in the general hospital. Therefore, further analysis is required on the cost containments and benefits as turn over rate per bed as the medical prime costs. The length of stay was most significant and was positive to the total medical expenditure, as expected. Surgery and patient's residential area was also an important variable in explaining medical expenditure. The level of complications was the most significant variable in explaining the length of stay. There was a high level for need a home health care nursing service which further supports early discharge for accident patients. In addition, when the patient was discharged. they needed follow up care for complications suffered during the car accident. $86.8\%$ of discharged patients responded that they needed home health services after early discharge. From these research findings, the following suggestions have been drawn. Strategies on a health care delivery system must be developed in order to focus on the consumer's needs and being planned for 21 century health policy in Korea. Community based intermediate facilities or home health care should be developed for rehabilitation services as a substitute for hospitalization in order to shorten the length of stay would be. A hospital based home health care nursing service. it would be available immediately to utilize by patients who want rehabilitation services as a substitute for hospitalization with the cooperation of car insurance companies.

  • PDF

A Study on the Introduction of Fuzzy Theory to the Adjustment of Time Variant parameter

  • Lee, Jong-Kyu;Lee, Chang-Hae
    • Korean Journal of Hydrosciences
    • /
    • v.8
    • /
    • pp.69-83
    • /
    • 1997
  • The Parameters of the storage function model (SFM) are taken as constants, while they have different values during every rainfall period and the duration of the runoff. Therefore, the results of the SFM generally show remarkably large errors. In this study, the modified storage function model (MSFM), in which the time variant parameters are introduced, is proposed to improve the SFM which is a conceptual rainfall-runoff model. The fuzzy reasoning method is applied as a real-time control one of the time variant parameters of the proposed model. The applicability of the MSFM was examined in the Bochung river, at a tributary of the Geum River, Korea. The pattern of the predicted runoff hydrograph and the peak discharge by the MSFM with fuzzy control are very similar to the measured values, compared with the results produced by the SFM.

  • PDF

The study on the technic of real time efficiency management of hydro turbine -generator (수차 발전기의 실시간 효율관리 기법 연구)

  • Kim, Seung-Hyo;Kwon, Young-June
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1018-1020
    • /
    • 2000
  • In the operation and maintenance activity of hydro turbine generator, one of the important parameters is the efficiency. This study analyze the case of efficiency management by pressure time method and survey the application of this method through the actual test. And it is confirmed that the Pressure time method exccesively limit the general condition to be applied. If index method is used for efficiency management because the index method calibrated by absolute discharge(by flow of pressure time method) is very accurate. it make to be able to manage the realtime efficiency.

  • PDF

DEVELOPMENT OF A REAL-TIME FLOOD FORECASTING SYSTEM BY HYDRAULIC FLOOD ROUTING

  • Lee, Joo-Heon;Lee, Do-Hun;Jeong, Sang-Man;Lee, Eun-Tae
    • Water Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.113-121
    • /
    • 2001
  • The objective of this study is to develop a prediction mode for a flood forecasting system in the downstream of the Nakdong river basin. Ranging from the gauging station at Jindong to the Nakdong estuary barrage, the hydraulic flood routing model(DWOPER) based on the Saint Venant equation was calibrated by comparing the calculated river stage with the observed river stages using four different flood events recorded. The upstream boundary condition was specified by the measured river stage data at Jindong station and the downstream boundary condition was given according to the tide level data observed at he Nakdong estuary barrage. The lateral inflow from tributaries were estimated by the rainfall-runoff model. In the calibration process, the optimum roughness coefficients for proper functions of channel reach and discharge were determined by minimizing the sum of the differences between the observed and the computed stage. In addition, the forecasting lead time on the basis of each gauging station was determined by a numerical simulation technique. Also, we suggested a model structure for a real-time flood forecasting system and tested it on the basis of past flood events. The testing results of the developed system showed close agreement between the forecasted and observed stages. Therefore, it is expected that the flood forecasting system we developed can improve the accuracy of flood forecasting on the Nakdong river.

  • PDF

Determination of State-Space Model for Parameter Estimation of Tank Model (탱크모형의 매개변수추정을 위한 상태공간모형의 결정)

  • 이관수;이영석;정일광
    • Water for future
    • /
    • v.28 no.2
    • /
    • pp.125-136
    • /
    • 1995
  • The propose of this study is improve the uncertainty of parameter choice of tank model by the trials and errors method. The real time prediction of parameter by using the Kalman filter is practiced to get the effective prediction algorithm of low flow runoff. Even though the total discharge of runoff through the orifice of each tank should be similar to the observed discharge, the tank model which can show the various basin characteristic is influenced by the runoff circumstances. As a result of the real-time estimation of the tank model parameter by the state-space type of Kalman filter, the variation of runoff circumstances is static when the convergence of observed value and estimated value keeps the ficed high point. The parameter of tank model which is estimated by Kalman filter shows good result for low flow and reasonable adaptability where flow change abruptly. The Kalman filter method is proved to give better result than Automatic structure estimation method.

  • PDF

Automotive Airbag Inflator Analysis Using Measured Properties of Modern Propellants (추진제 특성을 이용한 에어백 인플레이터 성능 제어에 대한 실험 및 해석에 대한 연구)

  • Seo, Young-Duk;Kim, Gun-Woo;Hong, Bum-Suk;Kim, Jin-Ho;Chung, Suk-Ho;Yoh, Jai-Ick
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.6
    • /
    • pp.53-62
    • /
    • 2010
  • An airbag is composed of housing assembly, door assembly, cushion assembly, and an inflator. The inflator is the essential part that generates gas for airbag. When an airbag is activated, it effectively absorbs the crash energy of the passenger by inflating a cushion. In this study, tank tests were performed with newly synthesized propellants with various compositions, and the results are compared with the numerical results. In the simulation of inflator, a zonal model has been adopted which consisted of four zones of flow regions: combustion chamber, filter, gas plenum, and discharge tank. Each zone was described by the conservation equations with specified constitutive relations for gas. The pressure and temperature of each zone of the inflator were calculated and analyzed and the results were compared with the tank test data. In the zone of discharge tank the pressure quickly rose, the pattern of pressure curve was very similar to the pressure curve of real test. And in zone 1 & 2 & 3 the mass of products was increased and decreased with time. In zone 4, the mass of products was increased with time like real inflator. From the similarity of pressure curve in zone 4 and closed bomb calculation the modeled results are well correlated with the experimental values.

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.

Development of High-Performance Smart Battery for Notebook PCs with Lithium Ion Battery (리튬이온전지를 이용한 노트북 PC용 고성능 Smart Battery의 개발)

  • 김현수;문성인;윤문수;고병희;김동훈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.11
    • /
    • pp.1047-1054
    • /
    • 2003
  • Smart battery pack (SBP) for notebook PCs was developed using a cylindrical-type lithium ion battery. Batteries were connected with three serial and two parallel, the nominal capacity and the maximum load of SBP was 4,000mAh and 4.0A, respectively. The SBP was composed of a protection IC, by which safety of lithium ion batteries is maintained against overcharge, overdischarge and overcurrent, and a smart IC, which calculates the remaining capacity and the remaining run time. In matching test on notebook PC using Battery Mark 4.0, real and smart data of END voltage coincided nearly and LB and LLB signal worked norma]]y. And there were errors of less than 1% between the real and the smart data on the residual capacity in the charge and discharge test.

The Application of IRR-Camera for the Diagnosis of Surface Degradation (표면열화진단을 위한 적외선카메라의 응용)

  • Lim, Jang-Seob;Jeong, Seung-Chun;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.61-65
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF