• Title/Summary/Keyword: Real time RT-PCR (rRT-PCR)

Search Result 119, Processing Time 0.024 seconds

Comparison of Molecular Assays for the Rapid Detection and Simultaneous Subtype Differentiation of the Pandemic Influenza A (H1N1) 2009 Virus

  • Lee, Mi Kyung;Kim, Hye Ryoun
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.8
    • /
    • pp.1165-1169
    • /
    • 2012
  • In April 2009, the H1N1 pandemic influenza virus emerged as a novel influenza virus. The aim of this study was to compare the performances of several molecular assays, including conventional reverse transcription polymerase chain reaction (RT-PCR), two real-time reverse transcription (rRT)-PCRs, and two multiplex RTPCRs. A total of 381 clinical specimens were collected from patients (223 men and 158 women), and both the Seeplex RV7 assay and rRT-PCR were ordered on different specimens within one week after collection. The concordance rate for the two methods was 87% (332/381), and the discrepancy rate was 13% (49/381). The positive rates for the molecular assays studied included 93.1% for the multiplex Seeplex RV7 assay, 93.1% for conventional reverse transcription (cRT)-PCR, 89.7% for the multiplex Seeplex Flu ACE Subtyping assay, 82.8% for protocol B rRT-PCR, and 58.6% for protocol A rRT-PCR. Our results showed that the multiplex Seeplex assays and the cRT-PCR yielded higher detection rates than rRT-PCRs for detecting the influenza A (H1N1) virus. Although the multiplex Seeplex assays had the advantage of simultaneous detection of several viruses, they were time-consuming and troublesome. Our results show that, although rRT-PCR had the advantage, the detection rates of the molecular assays varied depending upon the source of the influenza A (H1N1)v virus. Our findings also suggest that rRT-PCR sometimes detected virus in extremely low abundance and thus required validation of analytical performance and clinical correlation.

Detection of a Microsporidium, Nosema ceranae, from Field Population of the Bumblebee, Bombus terrestris, via Quantitative Real-Time PCR (서양뒤영벌 야외개체군에서 Real-Time PCR을 이용한 Nosema ceranae의 검출)

  • Lee, Dae-Weon
    • Korean Journal of Microbiology
    • /
    • v.49 no.3
    • /
    • pp.270-274
    • /
    • 2013
  • The bumblebee, Bombus terrestris, has played an important role as one of the alternative pollinators since the outbreak of honeybee collapse disorder. Recently, pathogens and parasites such as viruses, bacteria and mites, which affect the life span and fecundity of their host, have been discovered in B. terristris. In order to detect the microsporidian pathogen, Nosema spp. in the field populations of B. terristris, we collected adults and isolated their genomic DNA for diagnostic PCR. The PCR primers specific for Nosema spp. were newly designed and applied to gene amplification for cloning. Only small subunit ribosomal RNA (SSU rRNA) gene of N. ceranae was successfully amplified among examined genes and sequenced, which indicates that N. ceranae mainly infects the examined field population of B. terristris. To detect of SSU rRNA gene, two regions of SSU rRNA gene were selected by primary PCR analysis and further analyzed in quantitative real-time PCR (qRT-PCR). The qRT-PCR analysis demonstrated that SSU rRNA of N. ceranae was detected at concentration as low as $0.85ng/{\mu}l$ genomic DNA. This result suggests that the detection via qRT-PCR can be applied for the rapid and sensitive diagnosis of N. ceranae infection in the field population as well as risk assessment of B. terristris.

Real-Time RT-PCR for Validation of Reovirus Type 3 Safety During the Manufacture of Mammalian Cell Culture-Derived Biopharmaceuticals (세포배양 유래 생물의약품 생산 공정에서 Reovirus Type 3 안전성 검증을 위한 Real-Time RT-PCR)

  • Lee, Dong-Hyuck;Jeong, Hyo-Sun;Kim, Tae-Eun;Oh, Seon-Hwan;Lee, Jung-Suk;Kim, In-Seop
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.228-236
    • /
    • 2008
  • Validation of viral safety is essential in ensuring the safety of mammalian cell culture-derived biopharmaceuticals, because numerous adventitious viruses have been contaminated during the manufacture of the products. Mammalian cells are highly susceptible to Reovirus type 3 (Reo-3), and there are several reports of Reo-3 contamination during the manufacture of biopharmaceuticals. In order to establish the validation system for the Reo-3 safety, a real-time RT-PCR method was developed for quantitative detection of Reo-3 in cell lines, raw materials, manufacturing processes, and final products as well as Reo-3 clearance validation. Specific primers for amplification of Reo-3 RNA was selected, and Reo-3 RNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be $3.2{\times}10^0\;TCID_{50}/ml$. The real-time RT-PCR method was proven to be reproducible and very specific to Reo-3. The established real-time RT-PCR assay was successfully applied to the validation of Chinese hamster ovary (CHO) cell artificially infected with Reo-3. Reo-3 RNA could be quantified in CHO cell as well as culture supernatant. When the real-time RT-PCR assay was applied to the validation of virus removal during a virus filtration process, the result was similar to that of virus infectivity assay. Therefore, it was concluded that this rapid, specific, sensitive, and robust assay could replace infectivity assay for detection and clearance validation of Reo-3.

Implementation of a Deep Learning-Based Computer-Aided Detection System for the Interpretation of Chest Radiographs in Patients Suspected for COVID-19

  • Eui Jin Hwang;Hyungjin Kim;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1150-1160
    • /
    • 2020
  • Objective: To describe the experience of implementing a deep learning-based computer-aided detection (CAD) system for the interpretation of chest X-ray radiographs (CXR) of suspected coronavirus disease (COVID-19) patients and investigate the diagnostic performance of CXR interpretation with CAD assistance. Materials and Methods: In this single-center retrospective study, initial CXR of patients with suspected or confirmed COVID-19 were investigated. A commercialized deep learning-based CAD system that can identify various abnormalities on CXR was implemented for the interpretation of CXR in daily practice. The diagnostic performance of radiologists with CAD assistance were evaluated based on two different reference standards: 1) real-time reverse transcriptase-polymerase chain reaction (rRT-PCR) results for COVID-19 and 2) pulmonary abnormality suggesting pneumonia on chest CT. The turnaround times (TATs) of radiology reports for CXR and rRT-PCR results were also evaluated. Results: Among 332 patients (male:female, 173:159; mean age, 57 years) with available rRT-PCR results, 16 patients (4.8%) were diagnosed with COVID-19. Using CXR, radiologists with CAD assistance identified rRT-PCR positive COVID-19 patients with sensitivity and specificity of 68.8% and 66.7%, respectively. Among 119 patients (male:female, 75:44; mean age, 69 years) with available chest CTs, radiologists assisted by CAD reported pneumonia on CXR with a sensitivity of 81.5% and a specificity of 72.3%. The TATs of CXR reports were significantly shorter than those of rRT-PCR results (median 51 vs. 507 minutes; p < 0.001). Conclusion: Radiologists with CAD assistance could identify patients with rRT-PCR-positive COVID-19 or pneumonia on CXR with a reasonably acceptable performance. In patients suspected with COVID-19, CXR had much faster TATs than rRT-PCRs.

Loop-mediated isothermal amplification assay for the rapid detection of swine influenza virus (등온증폭법을 이용한 돼지인플루엔자바이러스 신속 진단법 개발)

  • Kim, Eun-Mi;Jeon, Hyo-Sung;Kim, Ji Jung;Kim, Hee-Jung;Shin, Yeun-Kyung;Song, Jae-Young;Yeo, Sang-Geon;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.2
    • /
    • pp.107-116
    • /
    • 2015
  • In this study, we developed a rapid, sensitive and specific reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for detection of swine influenza viruse (SIV) including major subtypes of swine influenza viruses H1N1, H1N2 and H3N2, and a novel subtype of influenza A virus that accidentally infected in pig population. The RT-LAMP was completed in 40 min at $58^{\circ}C$ and the sensitivity of the RT-LAMP ($1copy/{\mu}L$) was 10-fold higher than conventional reverse transcription-polymerase chain reaction (RT-PCR) ($10copy/{\mu}L$) and the same to real time RT-PCR ($1copy/{\mu}L$). Also, the result of the RT-LAMP can be confirmed without any detection system. Therefore, the RT-LAMP could be a alternative diagnostic method for SIV detection in national SIV monitoring system and clinical diagnostic laboratory in the future.

Development and Validation Study of Biological Agent Detection Kit (생물학작용제 검출 키트 개발 및 성능시험 연구)

  • Joe, Hae Eun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.575-580
    • /
    • 2019
  • In biological warfare, it is important to identify biological agents for proper treatment. We focused on developing a real-time RT-PCR kit that can detect multiple species of biological agents. AccuPower(R) Biothreat Real-Time RT-PCR Kit(v3.0) could detect Bacillus anthracis, Yersinia pestis, Vibrio cholerae, Francisella tularensis, Salmonella typhi, Rickettsia prowazekii, Variola virus, Hantaan virus, Yellow fever virus, Brucella spp., Shigella dysenteriae in a single reaction. The results showed that the kit was verified to be able to detect at least 0.005 ng of nucleotide and 10,000 CFU/ml of bacteria. Therefore, the kit is expected to be used as a rapid and sensitive detection kit for 11 species of biological agents within 2 hours.

Rapid Detection and Monitoring Therapeutic Efficacy of Mycobacterium tuberculosis Complex Using a Novel Real-Time Assay

  • Jiang, Li Juan;Wu, Wen Juan;Wu, Hai;Ryang, Son Sik;Zhou, Jian;Wu, Wei;Li, Tao;Guo, Jian;Wang, Hong Hai;Lu, Shui Hua;Li, Yao
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.9
    • /
    • pp.1301-1306
    • /
    • 2012
  • We combined real-time RT-PCR and real-time PCR (R/P) assays using a hydrolysis probe to detect Mycobacterium tuberculosis complex (MTBC)-specific 16S rRNA and its rRNA gene (rDNA). The assay was applied to 28 non-respiratory and 207 respiratory specimens from 218 patients. Total nucleic acids (including RNA and DNA) were extracted from samples, and results were considered positive if the repeat RT-PCR threshold cycle was ${\leq}35$ and the ratio of real-time RT-PCR and real-time PCR load was ${\geq}1.51$. The results were compared with those from existing methods, including smear, culture, and real-time PCR. Following resolution of the discrepant results between R/P assay and culture, the overall sensitivity, specificity, positive predictive values (PPV), and negative predictive values (NPV) of all samples (including non-respiratory and respiratory specimens) were 98.2%, 97.2%, 91.7%, and 99.4%, respectively, for R/P assay, and 83.9%, 89.9%, 72.3%, and 94.7%, respectively, for real-time PCR. Furthermore, the R/P assay of four patient samples showed a higher ratio before treatment than after several days of treatment. We conclude that the R/P assay is a rapid and accurate method for direct detection of MTBC, which can distinguish viable and nonviable MTBC, and thus may guide patient therapy and public health decisions.

Comparison of clinical diagnostic performance between commercial RRT-LAMP and RT-qPCR assays for SARS-CoV-2 detection

  • Kim, Hye-Ryung;Park, Jonghyun;Han, Hyung-Soo;Kim, Yu-Kyung;Jeon, Hyo-Sung;Park, Seung-Chun;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.3
    • /
    • pp.163-168
    • /
    • 2021
  • The rapid and reliable detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) plays a key role in isolating infected patients and preventing further viral transmission. In this study, we evaluated the clinical diagnostic performances of a commercial real-time reverse transcription loop-mediated isothermal amplification (RRT-LAMP) assay (Isopollo® COVID-2 assay, M-monitor, Daegu, Korea) using eighty COVID-19 suspected clinical samples and compared these with the results of a commercial real-time reverse transcription polymerase chain reaction (RT-qPCR) assay (AllplexTM 2019-nCoV rRT-QPCR Assay, SeeGene, Seoul, Korea). The results of the RRT-LAMP assay targeting the N or RdRp gene of SARS-CoV-2 showed perfect agreement with the RT-qPCR assay results in terms of detection. Furthermore, the RRT-LAMP assay was completed in just within a 20-min reaction time, which is significantly faster than about the 2 h currently required for the RT-qPCR assay, thus enabling prompt decision making regarding the isolation of infected patients. The RRT-LAMP assay will be a valuable tool for rapid, sensitive, and specific detection of SARS-CoV-2 in human or unexpected animal clinical cases.

Measurement of DNA Damage with Fpg/Endo III FLARE Assay and Real Time RT-PCR in SD Rats Exposed to Cumene

  • Kim, Soo-Jin;Rim, Kyung-Taek;Lee, Seong-Bae;Kim, Hyeon-Yeong
    • Molecular & Cellular Toxicology
    • /
    • v.4 no.3
    • /
    • pp.211-217
    • /
    • 2008
  • To clarify the DNA damage from reactive oxygen species, we measured the DNA damage through Fpg/Endo III FLARE (Fragment Length Analysis with Repair Enzyme) assay and real time RT-PCR. The 80 SD rats assigned to 4 dose groups exposed to cumene vapor for 90 days. With Fpg/Endo III FLARE assay in hepatocytes, we found the OTM (Olive Tail Moment) and TL (Tail Length) significantly increased in no-enzyme treated and Fpg-treated control and 8 ppm groups with 28 days exposure. In Endo III-treated 8 ppm group, significantly increased the values with 90 days exposure. With lymphocytes, it was founded the values significantly increased in no-enzyme treated 800 ppm group in 28 and 90 days. It was significantly increased in Endo III-treated 80 ppm for 28 days and 800 ppm for 90 days. From the above findings, FLARE assay was suggested as being available as a biological marker for DNA damage induced by cumene exposure in SD rats. And we used real time RT-PCR for the OGG1 mRNA expression, it had dose-dependent biologic effects in 1 day exposure, but decrease the levels of rOGG1 mRNA. Our findings provide evidence that cumene exposure may cause suppression of rOGG1 in the rat hepatocytes or lymphocytes.

Rapid Detection Method for Human Rotavirus from Vegetables by a Combination of Filtration and Integrated Cell Culture/Real-Time Reverse Transcription PCR (Filtration과 Integrated Cell Culture/Real-Time Reverse Transcription PCR 기법을 이용한 채소류에서 Human Rotavirus 신속 검출)

  • Hyeon, Ji-Yeon;Chon, Jung-Whan;Song, Kwang-Young;Hwang, In-Gyun;Kwak, Hyo-Sun;Lee, Jung-Soo;Kim, Moo-Sang;Lee, Jung-Bok;Seo, Kun-Ho
    • Korean Journal of Microbiology
    • /
    • v.47 no.2
    • /
    • pp.117-123
    • /
    • 2011
  • The purpose of this study was to evaluate and compare different elution and concentration methods for optimization of human rotavirus (HRV) detection method using real-time RT-PCR and cell culture techniques. The leafy vegetable samples (lettuce, Chinese cabbage) were artificially inoculated with HRV. Viruses were extracted from the vegetables by two different elution buffers, buffer A (100 mM Tris-HCl, 50 mM glycine, 3% beef extract, pH 9.5) and buffer B (250 mM Threonine, 300 mM NaCl, pH 9.5), and the extracted viruses were concentrated by filtration and PEG precipitation sequentially. To determine infectivity of the viruses, the viruses recovered from the samples were infected to the MA-104 cells, and integrated cell culture real-time RT-PCR was performed at 1, 48, 72, 96, 120, 144, 168 h post-infection (p.i.). The elution buffer A was more efficient in extracting the virus from the produce samples tested than the buffer B, 29.54% and 18.32% of recoveries, respectively. The sensitivity of real-time RT-PCR method was markedly improved when the virus was concentrated by the filtration method. When the viruses were eluted and concentrated by buffer A and filtration, respectively, the average recovery rate was approximately 51.89%. When the viruses recovered from samples were infected to MA-104 cell, infectious HRV was detected within 48 h p.i. by ICC/real-time RT-PCR, whereas cytopathic effects were not observed until 72 h p.i. The optimized detection method evaluated in this study could be useful for rapid and reliable detection of HRV in fresh produce products and applied for detection of other food-borne viruses.