Implementation of C-HMI based Real-time Control and Monitoring for Remote Wastewater Reclamation and Reusing System (C-HMI 기반의 원격지 중수도 설비 실시간 제어와 모니터링 구현)

  • Lee, Un-Seon;Park, Man-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.717-722
    • /
    • 2013
  • The wastewater reclamation and reusing system has been rising as an alternative of water resource exhaustion that the whole world is experiencing. In order to be able to bring about improvement of the existing wastewater reclamation and reusing system, this research has developed of Conversion-Human Machine Interaction (C-HMI) based real-time control and monitoring system such as a sensor module and gate module, web monitoring system. This system was communication almost-error-free in various environment and situation. As a result, we have achieved our goal that has to doing work correctly as a sensor and gateway module that communication error is less than 0.2% throughout the embodied system and add that it can be easily controled and configured as an interface equipment to a complex sensor of water quality. According to this, the construction of a database capable of analyzing and assessing collection, storage and various elements of reliable water quality and flow rate data can be possible.

Development of a remote monitoring system for gas detection at the subway station (지하철 역내 가스 검출 원격 모니터링 시스템 구현)

  • Park, Yong-Man;Kim, Hei-Sik;Kim, Gyu-Sik;Lee, Moon-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

A Study on Track Record and Trajectory Control of Robot Manipulator with Eight Joints Based on Monitoring Simulator for Smart Factory

  • Kim, Hee-jin;Jang, Gi-won;Kim, Dong-ho;Han, Sung-hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_1
    • /
    • pp.549-558
    • /
    • 2020
  • We describe a new approach to real-time implementation of track record and trajectory control of robotic manipulator with eight joints based on monitoring simulator. Trajectory generator uses the kinematic equations of the arm to convert the task description into a series of set points for each of the joint control loops, while the joint controllers, with simple algorithms for just one joint can move at a fast sampling rate, guaranteeing a smooth motion. The proposed control scheme is robust, fast in computation, and suitable for real-time control. Moreover, this scheme does not require any accurate parameter information, nor values of manipulator parameters and payload. Reliability of the proposed technology is veriefied by monitoring simulation and experimental of robot manipulator for the smart factory with eight degrees of freedom.

Confirmation of the Efectiveness of Remote Chemical Spills and Leak Monitoring System through Acetone Pool Evaporation Experiments (아세톤 풀 증발 실험을 통한 원격 유·누출 모니터링 시스템의 효용성 확인)

  • Eun Hee, Kim;Seul Gi, Lee;Byung Chol, Ma
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.25-31
    • /
    • 2022
  • In this study, the spill and leak system is developed to provide real-time remote monitoring of industrial complexes where chemical accidents have been occurring every year. The spill and leak monitoring system uses IR-RCD equipment mounted on a 70m-high steel tower to detect chemical substances, thereby detecting chemical accidents such as leaks, fires, and explosions in real time. If IR-RCD equipment can actually detect chemical substances at a long distance, accurate and rapid initial response can be expected. Therefore, in order to confirm that IR-RCD equipment can detect chemical leakage accidents occurring at a long distance, acetone was selected as the experimental substance and a detection experiment was designed. The experiment was conducted using the acetone pool evaporation method at the wharf which was located 1.5 km away from IR-RCD equipment, and it was confirmed whether IR-RCD equipment could detect acetone in real time through the control monitor.

Bio-Signal Data Collection and Monitoring System Using Time Series DB. (시계열 DB를 이용한 생체신호 데이터 수집 및 모니터링 시스템)

  • Kang, Dong-Yoon;Joo, Moon-Il;Hussain, Ali;Kim, Hee-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.211-212
    • /
    • 2021
  • Recently, as interest in health increases, the wearable market that can collect various biometric information is expanding. In addition, telemedicine and healthcare services through these bio-signals are expected to become common. In this paper, we introduce a service that can store bio-signals collected through IoT equipment in a database and monitor them in real time through the web. By implementing a system for collecting and storing biometric data and real-time monitoring, it can be utilized for various health management diagnosis.

  • PDF

Combustion Stability for Utility Gas Turbines : Development of a Real-Time Assessment Software (발전용 가스터빈의 실시간 연소안정성 평가 소프트웨어 개발)

  • In, Byeung Goo;Song, Won Joon;Cha, Dong Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.306-315
    • /
    • 2017
  • This study introduces a software for real-time assessment of combustion stability for utility gas turbines. The software was written with LabView, and implemented the time-domain kurtosis as a parameter to proactively access the instantaneous combustion stability during operation of the industrial gas turbine. The simple time-domain assessment algorithm incorporated in the software is advantageous over conventional frequency-domain signal processing of dynamic pressure signal since it reduces the computational cost, thereby making the algorithm more appropriate for real-time monitoring of combustion stability. Benchmark data obtained from a model gas turbine combustor were used for the reproducibility test of the software. The assessment obtained from the software agreed well with previously published results, indicating that incorporation of the software could enhance the performance of systems monitoring the combustion stability for gas turbines during power generation.

Real-time FECG monitoring system using digital signal processing (디지탈 신호처리에 의한 실시간 태아 심전도 감시 시스템)

  • 김남현;김원기;윤대희;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.580-585
    • /
    • 1990
  • This paper presents a real time FECG signal monitoring system in which an adaptive multichannel noise canceller is implemented using a Texas Instruments TMS32020 digital signal processor. Abdominal ECG signal is applied as the desired output and 3 chest ECG signals as the reference input signals of the adaptive multichannel noise canceller whose coefficients are updated using the LMS algorithms.

  • PDF

Real Time CUSUM Control of Plasma Impedance Matching Network (플라즈마 임피이던스 정합망 실시간 CUSUM 제어)

  • Kim, Woo-Suk;Kim, Byung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1844-1845
    • /
    • 2007
  • A CUSUM control chart was used to monitor semiconductor plasma equipment. The performance of plasma monitoring was evaluated with various combinations of design variables involved in CUCUM control chart. Experimental data collected by using a real-time matching monitoring system include electrical positions of impedance and phase positions, and reflected power. The evaluation revealed that by determining specific design variables plasma states could be more strictly monitored.

  • PDF

Supervisory Monitoring of Railway Signalling Devices by Spying Technique (스파잉 기법에 의한 철도신호제어설비 집중감시기법)

  • Kim, Byung-Chun;Choi, Kyu-Hyoung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1592-1594
    • /
    • 2005
  • This paper presents a method to construct a supervisory monitoring system for railway signaling devices which can provide the real-time operation information of signalling devices to several maintenance depots. Spying technique has been applied to acquire the real-time data transmitted among railway signaling devices without interfering the railway signalling system function.

  • PDF

In-service Real-time and Continuous Objective Video Quality Assessment for DTV Broadcasting

  • Han, Chan-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2013
  • This article presents a simple and reasonable in-service, real-time, and continuous single-ended objective video quality assessment model for DTV broadcasting using a multiburst signal at the bottom of the transient effect area, similar to Vertical Interval Test Signals. The issue of in-service video-quality monitoring in DTV broadcasting is addressed, and an effective method of quality monitoring is presented. The proposed method is also implemented and tested in a range of situations using a simulated HDTV broadcasting network.