• Title/Summary/Keyword: Real grid

Search Result 710, Processing Time 0.028 seconds

OPTIMUM STORAGE REALLOCATION AND GATE OPERATION IN MULTIPURPOSE RESERVOIRS

  • Hamid Moradkhani
    • Water Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.57-62
    • /
    • 2002
  • This research is intended to integrate long-term operation rules and real time operation policy for conservation & flood control in a reservoir. The familiar Yield model has been modified and used to provide long-term rule curves. The model employs linear programming technique under given physical conditions, i.e., total capacity, dead storage, spillways, outlet capacity and their respective elevations to find required and desired minimum storage fur different demands. To investigate the system behavior resulting from the above-mentioned operating policy, i.e., the rule curves, the simulation model was used. Results of the simulation model show that the results of the optimization model are indeed valid. After confirmation of the above mentioned rule curves by the simulation models, gate operation procedure was merged with the long term operation rules to determine the optimum reservoir operating policy. In the gate operation procedure, operating policy in downstream flood plain, i.e., determination of damaging and non-damaging discharges in flood plain, peak floods, which could be routed by reservoir, are determined. Also outflow hydrograph and variations of water surface levels for two known hydrographs are determined. To examine efficiency of the above-mentioned models and their ability in determining the optimum operation policy, Esteghlal reservoir in Iran was analyzed as a case study. A numerical model fur the solution of two-dimensional dam break problems using fractional step method is developed on unstructured grid. The model is based on second-order Weighted Averaged Flux(WAF) scheme with HLLC approximate Riemann solver. To control the nonphysical oscillations associated with second-order accuracy, TVD scheme with SUPERBEE limiter is used. The developed model is verified by comparing the computational solutions with analytic solutions in idealized test cases. Very good agreements have been achieved in the verifications.

  • PDF

Evaluation and Analysis of Scheduling Algorithms for Peak Power Reduction (전력 피크 감소를 위한 스케줄링 알고리즘의 성능 평가 및 분석)

  • Sung, Minyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2777-2783
    • /
    • 2015
  • Peak power reduction is becoming increasingly important not only for grid operators but also for residential users. The scheduling of electric loads tries to reduce the power peak by splitting the power-on period of an electric device into multiple smaller ones and by interleaving the on-periods of every device in a holistic way. This paper analyzes the performance of EDF, LSF, TCBM, and lazy scheduling algorithms and proposes the enhancement schemes. For analysis, we have implemented the scheduling policies in a simulation environment for distributed control systems. Through extensive experiments using real power traces, we discuss their performance characteristics in terms of power deviation, switch count, and temperature violation ratio. To prevent excessive switching, we propose to employ the concept of limited preemptibility and evaluate its effect on performance. It is found that the best performance is achieved when the scheduler capacity is dynamically adjusted to the actual power demand. The experiment results show that, by load scheduling, the probability of having a power deviation greater than 150W is reduced from 21.5% down to 3.2%.

Inundation Simulation on a Vertical Dock Using Finite Element Storm Surge Model (유한요소 폭풍해일 모형을 이용한 직립안벽에 대한 범람모의)

  • Suh, Seung-Won;Lee, Hwa-Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.4
    • /
    • pp.235-246
    • /
    • 2012
  • Typhoon induced surge simulations are done to make an establishment of coastal disaster prevention plan. To apply efficient run-up and overtopping on vertical harbor docks, in which prevailing wet-dry scheme cannot be satisfied due to infinite steepness, an imaginary internal barrier concept introduced and analyzed. Before real application on the Mokpo harbor area, feasibility tests are done on an idealized simple geometry and as a result it is found that the moderate width of the barrier might be 1 m. The threshold value of the minimum wet depth $H_{min}$ for land area, which behaves sensitive role in inundation area and depth, depends on grid size. However it is revealed that 0.01 m is adequate value in this fine finite element with 10 m spacing. A hypothetical typhoon of 100 years return period in central pressure and maximum velocity is generated based on historical tracks. Simulation of possible inundation on Mokpo area is performed with asymmetrical vortex of hypothetical typhoon and wave coupling. Model results show general agreement in pattern compared to other's prediction, however possibility of inundation enlargement is expected in harbor area.

Minimizing Redundant Route Nodes in USN by Integrating Spatially Weighted Parameters: Case Study for University Campus (가중치가 부여된 공간변수에 의거하여 USN 루트노드 최소화 방안 -대학 캠퍼스를 사례로-)

  • Kim, Jin-Taek;Um, Jung-Sup
    • Journal of the Korean Geographical Society
    • /
    • v.45 no.6
    • /
    • pp.788-805
    • /
    • 2010
  • The present USN (Ubiquitous Sensor Networks) node deployment practices have many limitations in terms of positional connectivity. The aim of this research was to minimize a redundancy of USN route nodes, by integrating spatially weighted parameters such as visibility, proximity to cell center, road density, building density and cell overlapping ratio into a comprehensive GIS database. This spatially weighted approach made it possible to reduce the number of route nodes (11) required in the study site as compared to that of the grid network method (24). The field test for RSSI (Received Signal Strength Indicator) indicates that the spatially weighted deployment could comply with the quality assurance standard for node connectivity, and that reduced route nodes do not show a significant degree of signal fluctuation for different site conditions. This study demonstrated that the spatially weighted deployment can be used to minimize a redundancy of USN route nodes in a routine manner, and the quantitative evidence removing a redundancy of USN route nodes could be utilized as major tools to ensure the strong signal in the USN, that is frequently encountered in real applications.

Electric Power Energy Saving and Efficient Measures in Buildings using the Smart-Meter (스마트미터를 활용한 건축물의 전력에너지 절감 및 효율화 방안)

  • Hwang, Hyun Bae;Jung, Byeong Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.365-372
    • /
    • 2014
  • In this paper, We implement a power-saving and efficient measures in buildings using the smart-meter. In order to save electric power energy, We propose an improved automatic power-factor controller(APFC) and demand control measures. This is achieved by controlling directly circuit breakers and the capacitor bank feeders in real time via a two-way smart-meter's ICT skills. Improved APFC is minimizing installation costs by series-parallel connecting heterologous capacitors to form a more diverse capacitor banking and controlling using the smart-meter. In order to suppress the demand power, We have designed a smart-meter with communication functions using Atmel's AVR465 and tested an operated lodging building for 24-hours. As a result, We made sure to always retained more than 95% power factor and did not occur over compensation.

The Study of Security Life Cycler Energy Service Platform or Universal Middleware (유니버설미들웨어상의 생명주기기반 보안에너지 서비스플랫폼 연구)

  • Lee, Hae-Jun;Hwang, Chi-Gon;Yoon, Chang-Pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.291-293
    • /
    • 2017
  • Security services that support electric energy service gateway require relatively high reliability. In particular, the application services that accompany communications and data are run organically. Each of the security services should support a secure service platform that supports a secure, scalable life cycle for existing services which should be extends security layer of Universal Middleware such as OSGi platform. In this convergence platform, it is the study of security transfer modular services that allow independent life cycle management of systems through Universal middleware. First, It is modular in terms of energy consumption service and data, enabling real-time operation, communications, remote management and applications. Second, the life cycle of the secure module to support the life cycle of secure, delete, start and updating of the security module by applying the security policy module layer concept. It is modular in terms of power generation and accountability, enabling us to distinguish between reliability and accountability in a large volume of data models in the smart grid, the service was intended to be standardized and applied to the security service platform.

  • PDF

Multimodal Imaging of Sarcopenia using Optical Coherence Tomography and Ultrasound in Rat Model

  • Jeon, Byeong Hwan;Chae, Yu-Gyeong;Hwang, Sang Seok;Kim, Dong Kyu;Oak, Chulho;Park, Eun-Kee;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.55-59
    • /
    • 2014
  • Sarcopenia, or reduced muscle mass and volume, is due to various factors such as senile change, neuronal degeneration, drug, malignancy, and sepsis. Sarcopenia with the aging process has been evidenced by the decline in muscle mass by 0.5 to 1% per year with 3-5% reduction in muscle strength for 10 years between the ages of 40 and 50, and a 1-2% of decline of mass every year in people aged 60-70. Therefore, early diagnosis and understanding the mechanism of sarcopenia are crucial in the prevention of muscle loss. However, it is still difficult to image changes of muscle microstructure due to a lack of techniques. In this study, we developed an animal model using denervated rats to induce a rapid atrophy in the tibialis anterior (TA) and imaged its structural changes using optical coherence tomography (OCT) along with histologic and ultrasound analyses. Ultrasound showed changes of overall muscle size. Histology revealed that the atrophic TA muscle displayed an increased size variability of muscle fiber and inflammatory changes. Three dimensional OCT imaged the changes of perimysial grid and muscle fiber structure in real time without sacrifice. These observed advantages of multimodal imaging using OCT and ultrasound would provide clinical benefits in the diagnosis of sarcopenia.

Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers (보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

Study on the Harmonic Extraction Technique of the Power Conditioning System using High Performance DSP Controller (고성능 DSP 제어기를 사용한 태양광인버터의 하모닉 추출기법에 대한 연구)

  • Lee, Jeong-Eun;Min, Jun-Ki;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.266-273
    • /
    • 2010
  • The main function of the power conditioning system (PCS) is grid-connection with renewable system. The level of total harmonic distortion(THD) caused by the PCS should be maintained less than 5% according to the IEEE-1547 regulation. The THD is measured by the dedicated instrument, not by the PCS in the domestic products. There should be the necessity for harmonic measurement by the PCS in order to cope with degradation or fault condition. In this paper, the real-time harmonic measurement technique using highperformance DSP controller is presented. The proto-system is manufactured using 32-bit floating DSP processor and tested with 256-point DFT(Discrete Fourier Transform) algorithm. The test result shows that the harmonic calculation time is less than 1 [ms]. It can be used as a auxiliary method for predicting the fault in the PCS system.

Decision-Making of Determining the Start Time of Charging / Discharging of Electrical Vehicle Based on Prospect Theory

  • Liu, Lian;Lyu, Xiang;Jiang, Chuanwen;Xie, Da
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.803-811
    • /
    • 2014
  • The moment when Electrical Vehicle (EV) starts charging or discharging is one of the most important parameters in estimating the impact of EV load on the grid. In this paper, a decision-making problem of determining the start time of charging and discharging during allowed period is proposed and studied under the uncertainty of real-time price. Prospect theory is utilized in the decision-making problem of this paper for it describes a kind of decision making behaviors under uncertainty. The case study uses the parameters of Springo SGM7001EV and adopts the historical realtime locational marginal pricing (LMP) data of PJM market for scenario reduction. Prospect values are calculated for every possible start time in the allowed charging or discharging period. By comparing the calculated prospect values, the optimal decisions are obtained accordingly and the results are compared with those based on Expected Utility Theory. Results show that with different initial State-of-Charge ($SoC_0$) and different reference points, the optimal start time of charging can be the one between 12 a.m. to 3 a.m. and optimal discharging starts at 2 p.m. or 3p.m. Moreover, the decision results of Prospect Theory may differ from that of the Expected Utility Theory with the reference points changing.