• Title/Summary/Keyword: Real grid

Search Result 709, Processing Time 0.034 seconds

Study on Optimal Real Time Pricing Model for Smart Grid in a Power Retailer Market (스마트 그리드 환경의 전력소매시장을 위한 최적의 실시간 가격결정 모형에 대한 연구)

  • Moon, Joon-Yung;Shin, Ki-Tae;Park, Jin-Woo
    • The Journal of Society for e-Business Studies
    • /
    • v.17 no.2
    • /
    • pp.105-114
    • /
    • 2012
  • Recently, global warming, energy shortage, and environmental disruption have been serious problems in every nation. It became more and more important to reduce the emission of CO2 and to use of energy efficiently. Smart grid was also introduced using the rapidly developing information technology. It deployed the mutual communication concept between customers and the suppliers in the electricity supply. There were increasing demands to adopt the smart meter and to present incentive for efficient energy usage in many developed countries. The objective of this research was to develop the optimal real time pricing model which maximized the profit of the power retailer and reduced the usage of energy. The simulation study was given to show the usefulness of the model. Simulation considered the customer demand response rate and price elasticity rate. The price elasticity rate was compared in the condition of fixed value according to time and variable value according to the customers. The optimal price model could maximize the profit of the power retailer and reduce the energy usage of the consumers.

Leakage detection and management in water distribution systems

  • Sangroula, Uchit;Gnawali, Kapil;Koo, KangMin;Han, KukHeon;Yum, KyungTaek
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.160-160
    • /
    • 2019
  • Water is a limited source that needs to be properly managed and distributed to the ever-growing population of the world. Rapid urbanization and development have increased the overall water demand of the world drastically. However, there is loss of billions of liters of water every year due to leakages in water distribution systems. Such water loss means significant financial loss for the utilities as well. World bank estimates a loss of $14 billion annually from wasted water. To address these issues and for the development of efficient and reliable leakage management techniques, high efforts have been made by the researchers and engineers. Over the past decade, various techniques and technologies have been developed for leakage management and leak detection. These include ideas such as pressure management in water distribution networks, use of Advanced Metering Infrastructure, use of machine learning algorithms, etc. For leakage detection, techniques such as acoustic technique, and in recent yeats transient test-based techniques have become popular. Smart Water Grid uses two-way real time network monitoring by utilizing sensors and devices in the water distribution system. Hence, valuable real time data of the water distribution network can be collected. Best results and outcomes may be produced by proper utilization of the collected data in unison with advanced detection and management techniques. Long term reduction in Non Revenue Water can be achieved by detecting, localizing and repairing leakages as quickly and as efficiently as possible. However, there are still numerous challenges to be met and future research works to be conducted in this field.

  • PDF

Estimation of minimum BESS capacity for regulating the output of wind farms considering power grid operating condition in Jeju Isalnd (제주지역 계통운전조건을 고려한 풍력발전단지용 최소 BESS용량 산정)

  • Jin, Kyung-Min;Kim, Seong Hyun;Kim, Eel-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.39-45
    • /
    • 2013
  • This paper presents the estimation of minimum BESS capacity for regulating the output of wind farms considering power grid operating condition in Jeju Island. To analyze the characteristics of wind farm outputs with a BESS, the real data of wind farms, Sung-San, Sam-dal and Hang-Won wind farm, located in the eastern part of Jeju island is considered. The wind farms are connected to Sung-san substation to transfer the electric power to Jeju power grid. Consequently, at PCC (Point of Common Coupling), it can see a huge wind farm connected to the substation and thus it can be expected that the smoothing effect is affected by not only the different wind speeds for each area but also the different mechanical inertia of wind turbines. In this paper, two kinds of simulation have been carried out. One is to analyze the real data of wind farm outputs during a winter season, and the other is to connect a virtual BESS to eliminate the unintended generating power changes by the uncontrolled wind farm outputs as shown in the former data. In the conclusion, two kinds of simulation results show that BESS installed in the substation is more efficient than each wind farms with BESS, respectively.

Modeling and Control of a Doubly-Fed Induction Generator (DFIG) Wind Power Generation System for Real-time Simulations

  • Byeon, Gil-Sung;Park, In-Kwon;Jang, Gil-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.61-69
    • /
    • 2010
  • This paper presents a study of a DFIG wind power generation system for real-time simulations. For real-time simulations, the Real-Time Digital Simulator (RTDS) and its user friendly interface simulation software RSCAD are used. A 2.2MW grid-connected variable speed DFIG wind power generation system is modeled and analyzed in this study. The stator-flux oriented vector control scheme is applied to the stator/rotor side converter control, and the back-to-back PWM converters are implemented for the decoupled control. The real-wind speed signal extracted by an anemometer is used for a realistic, reliable and accurate simulation analysis. Block diagrams, a mathematical presentation of the DFIG and a control scheme of the stator/rotor-side are introduced. Real-time simulation cases are carried out and analyzed for the validity of this work.

On Parameter Estimation of Growth Curves for Technological Forecasting by Using Non-linear Least Squares

  • Ko, Young-Hyun;Hong, Seung-Pyo;Jun, Chi-Hyuck
    • Management Science and Financial Engineering
    • /
    • v.14 no.2
    • /
    • pp.89-104
    • /
    • 2008
  • Growth curves including Bass, Logistic and Gompertz functions are widely used in forecasting the market demand. Nonlinear least square method is often adopted for estimating the model parameters but it is difficult to set up the starting value for each parameter. If a wrong starting point is selected, the result may lead to erroneous forecasts. This paper proposes a method of selecting starting values for model parameters in estimating some growth curves by nonlinear least square method through grid search and transformation into linear regression model. Resealing the market data using the national economic index makes it possible to figure out the range of parameters and to utilize the grid search method. Application to some real data is also included, where the performance of our method is demonstrated.

A Study on the Optimal Design for Smart Distribution System (스마트 배전시스템의 최적 구성 방안에 관한 연구)

  • Ji, Seong-Ho;Son, Jun-Ho;Song, Seok-Hwan;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.834-836
    • /
    • 2009
  • The authors have been discussed the optimal voltage regulation method and on-line real time method using artificial neural networks in the distribution system interconnected with Distributed Generation and Storage(DSG) systems. However, these methods have difficulty in dealing with the random load variations and operation characteristics of a number of DSG systems. To overcome these problems, this paper shows the basic concepts of smart grid system which is considered as one of the power delivery system in the near future and presents an evaluation method on the impacts of customer voltages by the operation of smart grid system. The smart grid system can change the system configuration in a flexible manner by using the static switches and offer the different power qualities in power services through the power quality control centers.

  • PDF

Control and Operation of a Small Scale Distributed Energy System (소규모 분산에너지시스템의 제어구조 및 운전 (마이크로터빈 중심))

  • Hong, Won-Pyo;Cho, Hoon-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1139_1141
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for grid-connected operation. The system comprises of a permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in grid-connected operation mode of a DG system. The control strategies for grid connected operation mode of DG system is also presented.

  • PDF

Best practices for GridFTP service in WAN (WAN 상에서의 GridFTP 최적화 구축)

  • Choi, Youn-Keun;Kim, Sung Jun;Sung, Jin Woo;Lee, Sang Dong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.527-529
    • /
    • 2007
  • We build the striped and parallel gridftp server on WAN and test to find the best parameters for high performance. Also we check the various problems about gridftp service as production level and propose a best configuration for real service environment.

  • PDF

A Study on the Power Loss Monitoring Methods with AMI systems (지능형 원격검침시스템을 이용한 전력손실 감시방법에 대한 연구)

  • Myoung, No-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.67-74
    • /
    • 2013
  • Major utilities have been focusing on R&D and nationwide business of AMI system which plays a vital role in SmartGrid whose concept is to maximize energy efficiency and optimize electric power facility management with exchanging real time information between utilities and consumers based on ICT technologies in power grid. In this paper, we suggest a power loss monitoring method using KEPCO's AMI system which is operating in fields and with the acquisition of AMI data and analyses verify the validation of a power loss monitoring method.

Analysis of Proportional Control for Grid Connected Inverter With LCL Filter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.247-249
    • /
    • 2008
  • There are many types of grid-connected inverter controllers; Synchronous Reference Frame (SRF)-based controller is the most popular methods. SRF-based controller is capable for reducing both of zero-steady state error and phase delay. However, SRF-based controller has a complex algorithm to apply in real application such as digital processor. Resonant controller is also reduced zero-steady state error, but its transfer function has a high order. In this paper, a simple proportional control is applied for grid connected inverter with LCL filter. LCL filter is a third order system. Applying a simple proportional controller is not increased the order of closed loop transfer function. By this technique, the single phase model is easily obtained. To reduce steady state error, proportional gain is set as high as possible, but it may produce instability. To compromise between a minimum steady state error and stability, the single phase model is evaluate through Root Locus and Bode diagram. PSIM simulation is used to verify the analysis.

  • PDF