• Title/Summary/Keyword: Reagent Management

Search Result 29, Processing Time 0.027 seconds

Reagent Cabinet Hazard Situation Identification System Utilizing Multiple Sensor Data (다중 센서 데이터를 활용한 시약장 위험상황 식별 시스템)

  • Lee, Hyunju;Choi, Hyungwook;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.63-68
    • /
    • 2018
  • Recently, safety accidents that occur in laboratories have occurred in various forms, so that a system that can reduce safety accidents in laboratories is required. The existing system identifies the danger situation according to the change of the temperature and the humidity, but the type of the danger situation is not known and the operation of the device is manually performed. Therefore, in this paper, we propose a system that identifies the danger situation of a reagent cabinet using multiple sensors and automatically operates the device. The internal environment of the reagent cabinet is measured in real time through the sensors and the sensor data is used to identify the danger situation. Also, when a danger situation is identified, the appropriate device is selected and operated automatically. In this way, identification of the danger situation of the reagent cabinet and automatic operation of the device will reduce the safety accidents occurring in the reagent cabinet.

Study on Safety Management Activity of Blood Test Room of Nuclear Medicine Department (핵의학과 혈액검사실의 안전 관리 활동에 대한 고찰)

  • Sim, Seong-Jae;Shin, Young-Kyun;Moon, Hyeong-Ho;Yoo, Seon-Hee;Jo, Shi-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.104-110
    • /
    • 2011
  • Purpose: The object evaluation method about medical institutes of these days increases credibility of consumers about medical services by conducting a certification system about medical institutes. In addition, as nuclear medicine test rooms and diagnosis test medicine room adopt many kinds of international certification systems, the matters regarding safety management of test rooms are being regarded as important. Since the blood test rooms of nuclear medicine are exposed to many harmful factors such as infection from clinical specimen and radioactive isotope reagent, there is a need to pay lots of attention to the safety management of staff and patients. Therefore, this study discusses safety management activities of staff and patients, which are conducted in the blood test rooms of the nuclear medicine department in Asan Medical Center. Materials and Methods: In the blood test rooms of the nuclear medicine department in Asan Medical Center, the matters regarding comprehensive safety management by the person in charge of safety management are offered and all staff members of the test rooms apply them into work. Safety management education is regularly conducted according to established regulations, and infection is prevented through implementation of wearing personal protectors and hand sanitation during test work. In addition, technical safety guides and accident guides for interruption of electric power are provided against emergencies. Through infection management guides, infection prevention and preparation methods for infection are learned and radioactive isotope management, safety management about reagent use and safety guides about harmful chemical substances are being applied to work. Results: The blood test rooms of the nuclear medicine department apply safety management regulations to work. Under the situation where hand sanitation should be conducted, hands are washed to prevent infection between staff and patients, and for preventing infection from clinical specimen, personal protectors are worn. The reagent, which is classified as harmful substance, is separately stored to be easily recognized, radioactive wastes and general medical wastes are also safely managed. Through these lots of safety management activities, safety management awareness of staff members is enhanced, and patients are protected from many dangers. Conclusion: Staff members of the blood test rooms of the nuclear medicine department should be fully aware of safety management regulations and apply them to work. When better safety management suggestions are made, they need to be examined and applied for increasing quality of safety management for staff and patients.

  • PDF

Effective Coagulation and Fenton Reagent Oxidation of Effluent from Biological Landfill Leachate Treatment (생물학적 처리 침출수의 응집 및 펜톤산화 처리)

  • Won, Jong-Choul;Namkoong, Wan;Park, Ki-Hyuk;Cho, Joon-Ho;Yoon, Cho-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.811-817
    • /
    • 2000
  • The objectives of this study are to determine optimal operation condition of chemical coagulation with ferric chloride($FeCl_3$) and fenton reagent oxidation for effluents of a biological denitrification treatment and an existing lagoon treatment of landfill leachate, and to investigate the effect of alkalinity on fenton oxidation. In jar-tester, optimum dosage of ferric chloride for removal of COD was $1,500mgFe^{3+}/L$, removal efficiencies of $COD_{Cr}$ and $COD_{Mn}$ under this condition were about 55% and 64%, respectively. After chemical precipitation($1,500mgFe^{3+}/L$) of biological treatment effluent, optimum $Fe^{2+}/H_2O_2$ ratio of fenton oxidation was 1.5, the maximum removal efficiency of COD was about 80%, and optimum dosages of ferrous sulfate and hydrogen peroxide were $600mgFe^{2+}/L$ and $400mgH_2O_2/L$, respectively. The removal efficiency of COD was decreased as alkalinity was increased.

  • PDF

Usability of Urinary Reagent Strips in Diagnosis of Meningitis (뇌수막염의 진단에서 뇨검사 시험지를 이용한 뇌척수액 검사의 유용성)

  • Jeong, Jin Yeong;Park, Sang Kyu
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.265-270
    • /
    • 1997
  • Purpose: Rapid diagnosis and prompt treatment remain the cornerstone of management of patients with meningitis. Examination of cerebrospinal fluid(CSF) for glucose, protein, cells, and organisms is necessary for accurate diagnosis, but in many parts of the world facilities do not exist to do so. We tested CSF samples from 69 children with suspected meningitis with urinary reagent strips and analyzed the results to know the usability of urinary reagent strips in diagnosis of meningitis. Methods: 69 CSF samples obtained from children with suspected meningitis were analysed. Each sample was divided into two; one was sent to the laboratory for routine diagnostic evaluation, and the other was tested with the reagent strip(Combur10 Test M). Laboratory values of CSF glucose, protein, and leucocytes for each CSF sample were plotted against the corresponding reagent-strip category. Results: There was good agreement between the dipstick and laboratory values for CSF protein and cell count but not for glucose. Conclusion: Rapid diagnosis of meningitis could be made with three component of the Combur10 test strip. It is easy to do and would be of particular value to those working in parts of the world where no laboratory facilities exist.

  • PDF

Reagent management system with sensors and RFID (센서와 RFID를 활용한 시약 관리시스템)

  • Kang, Hee-Beom;Jung, Han-Gil;Cung, Chee-Oh;Park, Sang-No;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.651-653
    • /
    • 2015
  • Common Embedded boards like the Arduino, Raspberry Pi, BeagleBone Black, leverages smart home systems, machine tools and various products in our day to day life. Managing and dealing frequent large scale incidents involving recent reagents and hazardous materials can be dangerous and difficult to detect in advance like in an event of an accidents or fires. In this paper I have done research by utilizing an Embedded (BeagleBone Black) boards sensors and RFID management system to detect a hazardous situation like fire in real time and avoiding it by sending out an alert message to the admin user to minimizing the risk. This system provides immediate information to the administrator of any hazardous situation and prevents any accidents from occurring.

  • PDF

The Coating Performance of UV Curable Urethane Acrylate Coatings for Fancy Veneer Overlayed Plywood Flooring

  • Lee, Byoung-Hoo;Kim, Hyun-Joong;Lee, Young-Kyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.23-35
    • /
    • 2004
  • The goal of study was to investigate the influence of the acrylated urethane oligomer on mechanical properties, the chemical resistance and thermal resistance of the UV curable urethane acrylate coatings for fancy veneer overlayed plywood flooring. The pencil hardness and abrasion resistance of the coated fancy veneer overlayed plywood floorings increased with increasing the acrylate functionality of the acrylated urethane oligomer. In the case of the UV cured film containing hexa-functional acrylated aliphatic urethane oligomer, high discoloration of the coated fancy veneer overlayed plywood flooring was observed near the cracks at the beginning of the chemical treatment. In this study, it was found that the degradation of the UV cured film caused by an alkaline reagent was higher than that of the UV cured film caused by an acidic treatment.

Determination of Veterinary Antibiotic Residues: III. Analytical Methods_A Review (시료 중 잔류 항생제 분석 방법: III. 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.649-669
    • /
    • 2016
  • This study explored the analytical conditions for 21 veterinary antibiotics which have been popularly sold in South Korea in 2014 but have not yet been targeted in EPA method 1694. Most of the selected antibiotics were separated by a reverse-phase C18 column with a combination of (buffered) water and organic polar solvent, which was commonly methanol and acetonitrile in the gradient elution mode. Volatile additives such as formic acid, ammonium acetate and ammonium formate were usually added to the mobile phases to minimize asymmetrical and tailing of antibiotics' peaks and to increase their ionization in mass spectrometry. The analytical methods of aminoglycoside antibiotics were distinct from those of the other antibiotics in terms of adoption of ion-pair chromatography (IPC) and hydrophilic interaction liquid chromatography (HILIC) capable of retaining and separating extremely polar compounds due to their hydrophilicity. Trifluoroacetic acid or heptafluorobutyric acid was frequently added to the mobile phase as an ion-pair reagent for the IPC. Tandem mass spectrometry was numerously applied to the detection of antibiotics using positive electrospray ionization (ESI) and the selected reaction monitoring (SRM) mode. All reviewed analytical methods had been/were validated by evaluating recovery, limits of detection and quantification, decision limit or detection capability of the methods.

Comparison of Dissolved Ammonium Analytical Method in Seawater: Spetrophotometry and Fluorometry (해수 중 용존 암모늄 분석방법 비교: 분광광도법과 형광법)

  • SON, PURENA;PARK, JOONSEONG;RHO, TAEKEUN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.25 no.4
    • /
    • pp.81-96
    • /
    • 2020
  • Berthlot's reaction spectrophotometric method is generally used for the analysis of dissolved ammonium in seawater, but in recent years, a fluorescence method using an orthophthaldialdehyde-sulfite (OPA) fluorescent reagent is actively used internationally. In this study, we investigated the effects of the detection limit between the analysis methods, the reagent refractive index inherent in the spectrophotometric method, and the use of different calibration curves to understand the cause of the difference in dissolved ammonium concentration (about 0.31 𝜇M) observed in the seawater samples and a nutrient reference material between two institutions (KIOST (spectrophotometric method, one-order linear regression gradient only), Australia CSIRO (fluorescence method, quadratic formula)) conducted onboard the Australian R/V Investigator in 2017. The method detection limit (0.063 𝜇M) and the reagent refractive index background value (0.054 𝜇M) of the spectrophotometric method measured in this study could explain the difference in dissolved ammonium concentration values of the two institutes about 20% and 17%, respectively. However, when the concentration of the calibration curve of the spectrophotometric method was calculated using the same quadratic as the fluorescence method or the slope and intercept of linear regression, the difference in the dissolved ammonium concentration between the two institutions was reduced to less than the detection limit of the spectrophotometric method. Therefore, the difference in the concentration of dissolved ammonium between the two institutions, found in the nutrient reference materials and the seawater field sample during the international onboard nutrient inter-comparison experiment, may be attributed to be the effect of the different calibration curves used in the two methods rather than the effect of the difference in two analytical methods. When comparing the dissolved ammonium data from seawater samples in the future, it is recommended to pay attention to the information on the baseline, number of standard solutions, and calibration curve used in the analysis.

Implementation of Microbial Identification Query System for Laboratory Medicine (진단검사의학을 위한 세균동정 쿼리시스템의 구현)

  • Koo Bong Oh;Shin Yong Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.1 s.33
    • /
    • pp.113-124
    • /
    • 2005
  • The work of investigation in the laboratory medicine includes various kinds of investigations and microbes and it is too complicated to draw needed results in time. So, we aim to improve work performance of the laboratory medicine. For this study, we implemented the scheduling system in microbe investigation using agent environment and the workflow management system to manage the schedule of investigation, and the query system to check the schedule. And preliminary report and final report of microbe investigation can be announced automatically using agent. The scheduling system implemented could identify the lack or waste of resources and thus enable efficient management and distribution of resources. The query system could check the schedule and retrieve the Processing status in short time, enabled the automated report, and reduced possible interrupts and the delay of work that can be occurred in confirming process. It also enables users to access from local and remote sites. Also, this system can reduce the conflicts among People that may occur in unexpected situations because it enables doctors to confirm those situations such as the malfunction of instrument and the lack of agar or reagent, and the efficiency of work process can be expected.

  • PDF

A Study on the Development of Soil-based PTMs for Analysis of Benzo[a]pyrene - Focusing on the Evaluation of Homogeneity and Stability for the Certification of Benzo[a]pyrenecandidate Reference Materials - (Benzo[a]pyrene 분석용 토양 숙련도 표준시료 개발에 관한 연구 - 후보 표준물질의 인증을 위한 균질성, 안정성 평가를 중심으로 -)

  • Lee, Minhyo;Lee, Guntaek;Joo, Changkyu;Kim, Yonghun;Lee, Bupyoel;Choe, Sunghun;Kim, Myeongock;Hong, Sukyoung;Kim, Gumhee;Lee, Wonseok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.49-58
    • /
    • 2014
  • This study was implemented as a part of the experiment to develop two kinds of soil-based Benzo[a]pyrene (BaP) proficiency testing materials (PTMs) for soil analysis. A test was carried out for the check of solubility of the reference material (high purity reagent) using several solvents. Another test was also conducted for the evaluation of homogeneity and stability of two kinds of candidate soil reference materials. The test analysis of BaP in terms of the candidate materials was conducted according to the Standard Soil Analytical Methods by Ministry of Environment. Dissolution of the reference material was shown to vary depending on solvent type and was higher in the order of Dichloromethane > Acetone > Acetone/MeOH (9 : 1) > N-hexane. In addition, the slope on calibration curve for BaP standard solutions was largest on BaP standard solutions prepared with dichloromethane of the tested solvents. Such tendency appeared egually in the commercial BaP standard solution. Therefore, it is thought to be reasonable to use dichloromethane as the solvent in case of the standard stock solution that is used for the measurement of BaP concentration in soil. ISO 13528 and IUPAC protocol were used for verification of homogeneity on the two kinds of soil candidate materials, Both candidate materials were sufficiently homogeneous. Stability assessment of the two candidate materials was made according to ISO Guide 35 and the result showed that both batches did not have any long-term and short term stability issues that might occur during shipping. However, monitoring results of BaP concentration in soil showed that BaP concentration of the two batches measured at 15 days after the sample preparation was reduced by about 24~37% compared with that of the samples measured on 0 day of the sample preparation. Identification was done with several treatments such as irradiation and sterilization etc. The major cause was shown to be irradiation to the samples.