• 제목/요약/키워드: Ready Mix Concrete

검색결과 46건 처리시간 0.031초

레디믹스드콘크리트의 조합설계안 분석보고 (An Analysis Report on the Mix Design of Ready Mixed Concrete)

  • 최민수;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.54-57
    • /
    • 1992
  • This report presents the survey findings on the proportioning of ready mixed, concrete mixtures. According to this report, the W/C ratio and S/A ratio, based upon the type 25-210-12, in mix proportion of ready mixed concrete are 53% and 45% respectively. The problems to be improved, coming out in this study, are (1)using the adequate quantity of cement (2) alternation of mix design cope with the change of kinds of aggregates (3)large standard error in the mix proportion.

  • PDF

Mix Design Nomogram을 이용한 콘크리트 파괴에너지 예측 (Prediction of Concrete Fracture Energy using Mix Design Nomogram)

  • 강성후;박선준;정철오
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권3호
    • /
    • pp.133-142
    • /
    • 2006
  • 본 연구에서는 레미콘 제품에 Mix Design Nomogram을 적용하여 배합변수에 따른 파괴에너지 예측뿐만 아니라 파괴에너지에 따른 배합변수 예측을 가능하도록 하는데 그 목적이 있다. Mix Design Nomogram 작성을 위한 실험은 레미콘 생산회사의 실제 시방배합표를 사용하였으며, RILEM 50-FMC 위원회에서 제안한 3점 휨 실험을 실시하였다. 그 결과, 레미콘 제품에 파괴에너지가 예측 가능한 Mix Design Nomogram의 적용 가능성을 확인하였으며, 이를 이용한 프로그램 개발로 레미콘 배합설계 자동화를 위한 가능성을 확인하였다.

배합표에 의한 경기북부 레미콘의 압축강도 추정에 관한 연구 (The Estimation of Compressive Strength of Ready-Mixed Concrete In the North Territory of Gyeonggi on the base of Mix Design)

  • 임창훈;지남용;조홍범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.979-984
    • /
    • 2003
  • Quality control of ready-mixed concrete is most important in the production step because, the performance of hardened concrete is revealed due to ready-mixed concrete. Hardened concrete has several properties physically. Above all things compressive strength of concrete has a greate effect in the design of structures, analysis, and durability. Compressive strength is simple predicted by w/c up to date, but there are some limits because different compressive strengths can be revealed in the same w/c. Therefore this study contributes to the quality control of ready-mixed concrete through statistical analysis for the relation between mix factors in mix design and compressive strength, predictable equation for compressive strength.

  • PDF

레디믹스트 콘크리트의 배합설계(配合設計)를 위한 컴퓨터의 이용에 관한 연구(研究) (Computer Application in Mix Design of Ready Mixed Concrete)

  • 문한영;최재진
    • 대한토목학회논문집
    • /
    • 제6권1호
    • /
    • pp.69-78
    • /
    • 1986
  • 레디믹스트 콘크리트의 품질은 시멘트의 품질, 골재의 입도 및 표면수 등과 같은 사용재료의 변화에 의하여 크게 변화하므로, 사용재료의 변화상태를 신속히 파악하여 배합계산에 반영함으로써 품질변화를 최대한 방지해야 한다. 본 논문에서는 레디믹스트 콘크리트의 배합계산에 컴퓨터를 사용함으로써 재료의 변화상태에 따른 배합수정을 정확하고 신속하게 처리하여 시방배합, 현장배합 및 배치량을 계산할 수 있는 프로그램을 작성하였다.

  • PDF

고강도-경량콘크리트의 배합설계 방안 및 역학적 특성에 관한 연구 (Study on the Mix Design Method and the Mechanical Proerties of High-Strenght Lightweight Concrete)

  • 강훈
    • 레미콘
    • /
    • 7호통권72호
    • /
    • pp.29-41
    • /
    • 2002
  • The purpose of this study is to investigarte the mix design method and the mechanical properties of High stength Lightweight Concrete (HSLC). In the experment, concrete mixing was conducted to select the optimum mix design for HSLC in laboratory. Also, concrete mixing in ready mix design. As a result, it is possible to establish the mix design of HSLC according to the using these experimental results ;the estimate equation for unit weight of HSLC. the relationship between W/C and compressive strength of HSLC and the fluidity of HSLC in the view of workability

  • PDF

레미콘 품질 안정화를 위한 효율적인 단위수량 관리 방안 (Efficient Unit-Water Management Method for Stabilizing the Quality of Ready-mixed Concrete)

  • 최성우;류득현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.327-328
    • /
    • 2021
  • In the manufacturing process of ready-mixed concrete, quantity management directly affects the workability and strength of concrete. Therefore, water quantity is the most important management factor for water quality control of ready-mixed concrete. It can be said that the number of unit water in the mix design, the water quantity due to the surface water contained in the aggregate used, and the water quantity taking into account the concentration of sludge contained in the recycling water when using the recycling water are factors that affect the quantity management of ready-mixed concrete. In this study, as a stable quality control method of ready-mixed concrete, a quantity management method by aggregate surface water and a sludge concentration management method according to the use of recycling water were proposed. Thus, we tried to suggest an efficient quantity management method for stabilizing the quality of ready-mixed concrete.

  • PDF

Investigation of Fiber Distribution in Concrete Batches Discharged from Ready-Mix Truck

  • Sorensen, Christian;Berge, Egil;Nikolaisen, Eirik B.
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권4호
    • /
    • pp.279-287
    • /
    • 2014
  • This paper presents the findings of an investigation of the fiber content variations in concrete being discharged from a ready-mix truck at the construction site. Concrete samples were extracted from the truck drums at the beginning, middle and end of discharge. Subsequently, fibers in each sample were separated from the concrete, and weighed. Presumably, synthetic macro fibers will float towards the top, i.e. towards the drum opening, of the inclined, revolving truck-drum, while, on the other hand, steel fibers will tend to gravitate towards the lower parts of the mixer drum. Accordingly, the discharge batch, containing synthetic macro fibers, will contain a higher amount of synthetic fibers per unit volume at the start of discharge than the average unit volume fiber content of the mix, and the content will gradually decrease further down the batch. The discharge batch of steel fiber concrete will contain fewer fibers per unit volume at the start of discharge than the average unit volume fiber content of the mix, and the content should gradually increase further down the batch. The correctness of the foregoing is partly confirmed. A certain percentage of the truck loads did not comply with the proposed requirements, mainly steel fiber reinforced batches, indicating the necessity of a code or guideline amendment. A change in the Norwegian shotcrete directive was made in 2011, based upon experimental research work (2010), which, in combination with the subsequent University of Life Sciences report (2012), constitutes the foundation of this article.

Dynamic mix design optimization of high-performance concrete

  • Ziaei-Nia, Ali;Shariati, Mahdi;Salehabadi, Elnaz
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.67-75
    • /
    • 2018
  • High performance concrete (HPC) depends on various parameters such as the type of cement, aggregate and water reducer amount. Generally, the ready concrete company in various regions according to the requirements and costs, mix design of concrete as well as type of cement, aggregates, and, amount of other components will vary as a result of moment decisions or dynamic optimization, though the ideal conditions will be more applicable for the design of mix proportion of concrete. This study aimed to apply dynamic optimization for mix design of HPC; consequently, the objective function, decision variables, input and output variables and constraints are defined and also the proposed dynamic optimization model is validated by experimental results. Results indicate that dynamic optimization objective function can be defined in such a way that the compressive strength or performance of all constraints is simultaneously examined, so changing any of the variables at each step of the process input and output data changes the dynamic of the process which makes concrete mix design formidable.

서중 고강도 레미콘 제조 및 품질관리 (Production and Quality Control of Hot Weathered Ready-Mixed High Strength Concrete)

  • 조일호;한정호;방희상;박기청
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.423-428
    • /
    • 1994
  • High strength concrete was placed at the mass concrete slabs, walls, pillars of RC building from August till August. And the construction is going on now. This paper presents mix design, production, quality control and experience with field application of high strength ready-mixed concrete under hot weathered conditions. It is shown to be possible to produce high strength concrete that has 45MPa compressive strength using superplasticizer and cement replaced with 20% fly-ash with appropriate control.

  • PDF

콘크리트 배합표에 의한 현장 콘크리트의 압축강도 추정에 관한 연구 (A Study on the Estimation of Compressive Strength of Ready-mixed Concrete On the basis of Mix-Design)

  • 조홍범;윤상천;지남용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.257-262
    • /
    • 2001
  • There are only a few tests to ensure concrete quality before placing in domestic situ; One is slump test for workability, the other is air content test for durability, the concrete compressive strength which is one of important factors to influence on concrete Quality has been tested after 28 days placing. Methods on early judgement of concrete strength have been introduced for concrete quality management, but such methods are time consuming, expensive, and required special expertise. Therefore, these have difficulty in situ application for concrete management. This study aimed at reviewing application of estimated equation of compressive strength as means for ready-mixed concrete, making an estimated equation which enables to estimate 28 days compressive strength by using regression formula analysis on basis of mixing designs of ready mixed concrete and results of compressive strength.

  • PDF