• 제목/요약/키워드: Reading error

검색결과 121건 처리시간 0.025초

광디스크의 물리어드레스 독출에러를 줄이기 위한 변조 및 검출방법 (New Modulation and Detection Method to Reduce Physical Address Reading)

  • 심재성;김기현;박현수;박인식;서중언;신동호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2505-2507
    • /
    • 2001
  • The RF signal is distorted since the cross-talk noise from adjacent tracks and ISI(Inter Symbol Interference) is also incresed as recording density is increased. These cross-talk noise and ISI are main reason of reading error for the embossed pits on the disc. In this study we suggest a new coding method, spaced modulation technique and a detection technique for the spaced modulation. We report the result shows detection performance is improved when we use the suggested spaced modulation code and the detection technique instead of conventional modulation code.

  • PDF

A Novel RFID Dynamic Testing Method Based on Optical Measurement

  • Zhenlu Liu;Xiaolei Yu;Lin Li;Weichun Zhang;Xiao Zhuang;Zhimin Zhao
    • Current Optics and Photonics
    • /
    • 제8권2호
    • /
    • pp.127-137
    • /
    • 2024
  • The distribution of tags is an important factor that affects the performance of radio-frequency identification (RFID). To study RFID performance, it is necessary to obtain RFID tags' coordinates. However, the positioning method of RFID technology has large errors, and is easily affected by the environment. Therefore, a new method using optical measurement is proposed to achieve RFID performance analysis. First, due to the possibility of blurring during image acquisition, the paper derives a new image prior to removing blurring. A nonlocal means-based method for image deconvolution is proposed. Experimental results show that the PSNR and SSIM indicators of our algorithm are better than those of a learning deep convolutional neural network and fast total variation. Second, an RFID dynamic testing system based on photoelectric sensing technology is designed. The reading distance of RFID and the three-dimensional coordinates of the tags are obtained. Finally, deep learning is used to model the RFID reading distance and tag distribution. The error is 3.02%, which is better than other algorithms such as a particle-swarm optimization back-propagation neural network, an extreme learning machine, and a deep neural network. The paper proposes the use of optical methods to measure and collect RFID data, and to analyze and predict RFID performance. This provides a new method for testing RFID performance.

에지 분석에 의한 자동 독화 실험 (Automatic Lip Reading Experiment by the Analysis of Edge)

  • 이경호;금종주;이상범
    • 한국컴퓨터산업학회논문지
    • /
    • 제9권1호
    • /
    • pp.21-28
    • /
    • 2008
  • 본 논문에서는 입술 주위 영상만으로 독화를 위한 에지 파라미터를 추출하였고, 한국어 5모음 'ㅏ/ㅔ/ㅣ/ㅗ/ㅜ'를 인식하는데 효과적임을 보였다. 발화하는 입주위의 이미지를 $5{\times}5$로 나누고, 각 영역에 소벨 연산자를 적용하여 디지털 에지 수를 구한 후, 이 값들의 관찰 오차를 정규화를 통하여 수정하고, 정규화 된 값을 파라미터로 사용하였다. 파라미터의 견인성을 확인하기 위하여, 자동 독화 시스템을 구축하였다. 인식 실험에 정상인 50명이 동원되었고, 10명의 이미지로 분석하고, 다른 40명의 이미지로 인식 실험을 하였다. 500개의 데이터를 분석하고, 이 분석을 바탕으로 신경망 시스템을 구축하였으며, 400개의 데이터로 인식 실험하였다. 신경망 시스템의 최고 인식 결과는 91.1%였다.

  • PDF

Clinical statistics: five key statistical concepts for clinicians

  • Choi, Yong-Geun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권5호
    • /
    • pp.203-206
    • /
    • 2013
  • Statistics is the science of data. As the foundation of scientific knowledge, data refers to evidentiary facts from the nature of reality by human action, observation, or experiment. Clinicians should be aware of the conditions of good data to support the validity of clinical modalities in reading scientific articles, one of the resources to revise or update their clinical knowledge and skills. The cause-effect link between clinical modality and outcome is ascertained as pattern statistic. The uniformity of nature guarantees the recurrence of data as the basic scientific evidence. Variation statistics are examined for patterns of recurrence. This provides information on the probability of recurrence of the cause-effect phenomenon. Multiple causal factors of natural phenomenon need a counterproof of absence in terms of the control group. A pattern of relation between a causal factor and an effect becomes recognizable, and thus, should be estimated as relation statistic. The type and meaning of each relation statistic should be well-understood. A study regarding a sample from the population of wide variations require clinicians to be aware of error statistics due to random chance. Incomplete human sense, coarse measurement instrument, and preconceived idea as a hypothesis that tends to bias the research, which gives rise to the necessity of keen critical independent mind with regard to the reported data.

주파수 의존형 전자근관장측정기 개발 및 임피던스차를 이용한 자동보정에 의한 성능향상 (Development of Frequency Dependent Type Apex-Locator Improvementation by Auto-calibration Using Impedance Difference)

  • 남기창;김수찬;김덕원;이승종
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.399-402
    • /
    • 1997
  • It is important to find a accurate root canal length or successful endodontic therapy. By X-ray method takes a long time and difficult in a curved canal. After developed electronic apex locator has allowed to measure the root canal length with easy, in a short time also in a curved canal. But most electronic apex locators have the disadvantage which is too short reading or sometimes the measurement itself becomes impossible if there are electrolytes in the canal. To overcome this drawback, impedance ratio method has been developed. In this study, we have developed frequency dependent electronic apex locator to minimize the interference of electrolytes. And based on that also some error in clinic use, we added the other method. Difference of two signals which are used in calculation of impedance ratio was can be represent the status of root canal fluid. As a result, using impedance ratio method and auto-calibration by voltage difference method can reduce the measurement error.

  • PDF

투약.수혈 바코드 시스템 적용 평가 (Evaluation of the Bar Code Medication Administration and Blood Transfusion System in a Tertiary Hospital)

  • 조명숙;송미라;장미라
    • 간호행정학회지
    • /
    • 제18권1호
    • /
    • pp.23-32
    • /
    • 2012
  • Purpose: The purpose of this study was to assess the clinical application of a bar code medication administration and blood transfusion system and to identify its effects from the aspect of patient safety and nurse satisfaction in a tertiary hospital. Methods: The system in this study was PDA with bar code reading capability and wireless networking function. The logs created during application of the system and administration error reports were analyzed. For nurses' satisfaction with the system, data were collected from 337 nurses using the instrument developed by Otieno et al. and analyzed using descriptive statistics. Results: The system application rate was 98.8%, and the main failure cases in the system application included bar code or network related factors. When the system was applied, 0.02% of errors were prevented. The nurses were satisfied with the system from the aspect of patient safety, however relatively less satisfied with the system from the aspect of work efficiency. Conclusion: The results of the study indicate the usefulness for patient safety of applying the bar code medication administration and blood transfusion system to clinical practice. However technological improvements including bar code and network communication are necessary to ensure higher work efficiency in nursing practice.

IEEE 802.11a 무선 랜에 적용할 Low Latency 인터리버 설계 (An interleaver design of low latency for IEEE 802.11a Wireless LAN)

  • 신보영;이종훈;박준;원동윤;송상섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 통신소사이어티 추계학술대회논문집
    • /
    • pp.200-203
    • /
    • 2003
  • By minimizing the burst error of data and correcting the error, we can define the convolution coding and interleaving in IEEE 802.11a wireless tan system. Two step block interleaver was decided by coded bits per OFDM symbol and due to this it comes to the delay time in IEEE 802.11a. This is the point of the question which we must consider. We try to decrease the delay time by all 48-clock from interleavings, and we have proposed a way carried out the interleaving outputs per symbol. So in comparison with the existing interleaver, we can decrease the delay time in reading and writing data, as well as reduce the delay time of bit re-ordering per symbol. Also this scheme is apply in all x-QAM cases.

  • PDF

The Medical Bed System for Preventing Pressure Ulcer Using the Two-Stage Control

  • Kim, Jungae;Lee, Youngdae;Seon, Minju;Lim, Jae-Young
    • International journal of advanced smart convergence
    • /
    • 제10권1호
    • /
    • pp.151-158
    • /
    • 2021
  • The main cause of ulcer is pressure, which starts to develop when the critical body pressure (32mmHg) is exceeded, and when the critical time elapses, ulcer occurs. In this study, the keyboard mechanism of the medical bed with 4 bar links was adopted, and each key can be controlled vertically. A key has one servo drive and one sensor controller which hasseveral body pressure sensors. The sensor controllers and the servo drives are connected to the main controller by two CAN (Car Are Network) in series, respectively. By reading the maximum body pressure value of each keyboard sensor, and by calculating the error value based on the critical body pressure, the fuzzy controller moves each key so that the total error becomes zero. If the fuzzy controller fails, then it prevents ulcer by lifting and lowering the keys of the bed alternatively within a short time. Thus, the controller operates in two-stage. The validity and effectiveness of the proposed approach have been verified through experiments.

서오보형 가속도계의 PMW 제어 (Control of Electromagnetic Accelermeter with Digital PWM Technique)

  • 김정한;오준호;제우성
    • 한국정밀공학회지
    • /
    • 제13권8호
    • /
    • pp.112-119
    • /
    • 1996
  • Among the various type of accelerometer, the servo rebalancing type accelermoter can be suitable for Inertial Navigation System, because of its high sensitivity and good response in low frequency. In this paper, we proposed a new technology to control inductive tuype accelerometer utilizing digital PWM method. The new developed digital PWM control has special design scheme for transmitting measurement value to outer device in its servo ollp. So it has no quantized error of transforming outputs of sensors to digital domain. The quantized error may make serious problem in INS system, because outputs of sensor are integrated once or twice by digital computer and it happens every sensor reading times. Therefore, in order to get the accurate information such as displacement, it is necessary to measure accurately the input current. In addition, Digital Signal Processing needs digital data transmission, digital PWM method is adaptive for this purpose. We realized a practical circuit for digital PWM control, analyzed the stability of the circuit, and designed the controller etc. In this study, we solved many practical problem for this application, and got out good results.

  • PDF

Multimodal audiovisual speech recognition architecture using a three-feature multi-fusion method for noise-robust systems

  • Sanghun Jeon;Jieun Lee;Dohyeon Yeo;Yong-Ju Lee;SeungJun Kim
    • ETRI Journal
    • /
    • 제46권1호
    • /
    • pp.22-34
    • /
    • 2024
  • Exposure to varied noisy environments impairs the recognition performance of artificial intelligence-based speech recognition technologies. Degraded-performance services can be utilized as limited systems that assure good performance in certain environments, but impair the general quality of speech recognition services. This study introduces an audiovisual speech recognition (AVSR) model robust to various noise settings, mimicking human dialogue recognition elements. The model converts word embeddings and log-Mel spectrograms into feature vectors for audio recognition. A dense spatial-temporal convolutional neural network model extracts features from log-Mel spectrograms, transformed for visual-based recognition. This approach exhibits improved aural and visual recognition capabilities. We assess the signal-to-noise ratio in nine synthesized noise environments, with the proposed model exhibiting lower average error rates. The error rate for the AVSR model using a three-feature multi-fusion method is 1.711%, compared to the general 3.939% rate. This model is applicable in noise-affected environments owing to its enhanced stability and recognition rate.