Applications of System Loss Sensitivity Index to Power Systems (손실감도지표의 전력계통 적용)

  • Lee, Sang-Jung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.2
    • /
    • pp.56-61
    • /
    • 2000
  • In the paper, the system loss sensitivity index that implies the incremental system loss with respect to the change of bus power is derived using optimization technique. The index λ reaches $\infty$ at critical loading point and can be applied to actual power systems for following purposes. 1) Evaluation of system voltage stability 2)Optimal investment of reactive power focused on minimizing system loss and maximizing system voltage stability 3)Optimal re-location of reactive power focused on minimizing system loss and maximizing system voltage stability 4)Optimal load shedding in case of severe system contingency focused on minimizing system loss and maximizing system voltage stability. Case studies for each application have proved their effectiveness.

  • PDF

Analysis of the Distribution STATCOM Operating Results for Improving Distribution System Power Quality (전력품질 향상을 위한 배전용 STATCOM 운전결과 분석)

  • 오관일;전영수;박상태;추진부
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.377-385
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. The custom power is similar in nature to the concept of FACTS(Flexibel AC Transmission System). By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources. STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, providing reactive power compensation, voltage regulation and mitigation of voltage flicker. It is shown that the STATCOM has clear advantages in areas such as; providing reactive power compensation and improving power factor.

  • PDF

Operational Analysis of Energy Storage System to Improve Performance of Wind Power System with Induction Generator (농형유도 풍력발전기의 성능개선을 위한 에너지저장장치의 동작특성 분석)

  • Lee, Ji-Heon;Shim, Myong-Bo;Lee, Hye-Yeon;Han, Byung-Moon;Yang, Seung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1138-1145
    • /
    • 2009
  • This paper presents an active and reactive power compensator for the wind power system with squirrel-cage induction generator. The output power of a wind power system changes irregularly according to the variation of wind speed. The developed system is able to continuously compensate the active and reactive power. The 3-phase inverter operates for the compensation of reactive power, while the DC/DC converter with super-capacitors operates for the compensation of active power. The operational feasibility of the proposed model was verified by simulations with PSCAD/EMTDC and the feasibility of hardware implementation was confirmed by experimental works with a scaled hardware model. The proposed compensator can be expected that developed system may be used to compensated the abrupt power variation due to sudden change of wind speed or sudden power-drop by tower effect. It can be also applied for the distributed generation and the Micro-Grid.

Performance Verification of Anti-Islanding of Reactive Power Variation Method using Positive Feedback (정궤환을 이용한 무효전력 변동기반의 단독운전 방지 성능 검증)

  • Jo, Jongmin;Shin, Chang-Hoon;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.105-110
    • /
    • 2019
  • This study proposed a reactive power variation (RPV) method equipped with positive feedback (PF) for detecting the islanding operation of distributed generation systems. The proposed RPV consists of the constant reactive power component and a certain reactive power term and uses the frequency deviation between the rated and the measured frequencies. The constant reactive power is injected from distributed generation system and power factor is to 0.9975 in grid-connected operation. PF is activated from generation of the frequency deviation and the injected reactive power is continuously increased due to PF when islanding occurs. Consequently, the increasing reactive power causes the point of common coupling frequency to deviate from the maximum/minimum threshold level. Performance of the proposed RPV is verified in a 1.7 kW T-type inverter, and the detection times are 53 and 150 ms.

Analysis of reactive species in water activated by plasma and application to seed germination

  • Choi, Ki-Hong;Lee, Han-Ju;Park, Gyungsoon;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.162.1-162.1
    • /
    • 2015
  • The use of plasma has increased in bio-application field in recent years. Particularly, water treated by arc discharge or atmospheric pressure plasma has been actively utilized in bio-industry. In this study, we have developed a plasma activated water generating system. For this system, two kinds of plasma sources; dielectric barrier discharge (DBD) plasma and arc discharge plasma have been used. The discharge energy was calculated using the breakdown voltage and current, and the emission spectrum was measured to investigate the generated reactive species. We also analyzed the amount of reactive oxygen and nitrogen species in water using the chemical methods and nitric oxide sensor. Finally, the influence of plasma generated reactive species on the germination and growth of spinach (Spinacia oleracea) was investigated. Spinach is a green leafy vegetable that contains a large amount of various physiologically active organic compounds. However, it is characterized with a low seed germination rate.

  • PDF

Dyeing Characteristics of Casein Protein Fiber with Acid Dyes and Reactive Dyes

  • Choi, Jae-Hong;Kim, Mi-Hyeon
    • Textile Coloration and Finishing
    • /
    • v.20 no.5
    • /
    • pp.14-22
    • /
    • 2008
  • The present paper focuses on the application of commercial acid dyes and wool reactive dyes to casein protein fabric. Nine acid dyes and six wool reactive dyes were compared their dyeing properties as well as color fastness. The exhaustion yields were higher than 80 % which dramatically increased at pH 3. Excellent wash fastness was obtained with metal-complex acid and wool reactive dyes. Both light and rubbing fastness were overall good, but perspiration fastness was comparatively poor.

A Study on Reduction of Reactive Power by PWH Voltage Converter (PWM 전압형 컨버터에 의한 무효전력 보상에 관한 연구)

  • Park, Min-Ho;Choi, Jae-Ho;Kim, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.269-272
    • /
    • 1988
  • This paper introduces a method to reduce the reactive power required by electronic converters. The instantaeous reactive power is calculated and compensated by the current controlled PWH voltage source converter connected parallel between the power lines and the converter. A high performance current control technique which is based on the current deviation vector is used for the PWM converter as compensator of reactive power. Accurate compensation of the reactive power and t control system ensuring fast response to the sudden change of loaf are attained. The converter structure and control scheme are discussed. Simulation of the system is performed.

  • PDF

Reactive-dyeable Treatment of PET Fabrics via Photografting of Dimethylaminopropyl methacrylamide

  • Huang, Weiwei;Jang, Jin-Ho
    • Textile Coloration and Finishing
    • /
    • v.21 no.2
    • /
    • pp.40-47
    • /
    • 2009
  • Dimethylaminopropyl methacryamide was photografted onto PET fabrics by continuous UV irradiation under ambient conditions. Several factors affecting the photografting were studied including irradiation energy, monomer and photoinitiator concentrations. ATR and ESCA analysis showed the successful grafting of the monomer onto the PET surface. The grafted PET fabrics showed higher zeta potentials below pH 7 compared with the ungrafted PET. The dyeability of the grafted PET fabrics to two $\alpha$-bromoacrylamide reactive dyes was investigated under various dyeing conditions including dye concentration, pH, dyeing temperature and time. The grafting imparted the reactive dyeability to PET fabrics, which was proportional to the grafted monomer content. The reactive dyeing behavior of the grafted PET fabrics was similar to that of conventional wool fabrics.

Corrective-mode based Security constrained Benders decomposition approach toward Preventive-mode Optimal Reactive Power Planning (안전도 제약 Benders 분해법을 적용한 예방모드 무효전력투입 최적화 방안)

  • Jeong, Jong-Hoon;Song, Hwa-Chang;Lee, Byoung-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.184-186
    • /
    • 1999
  • This paper presents a method for security constrained optimal reactive power planning in electric power systems. This method deals with corrective mode optimal reactive power dispatch in each (n-1)contingency system state and determination of the location and amount of reactive sources in preventive mode. In this paper the proposed scheme uses Benders decomposition method to determine the proper amount and location of reactive support in order to maintain a proper voltage profile and minimize active power transmission losses. This method is tested on IEEE 30 bus test system to prove effectiveness.

  • PDF

Reactive Current Assignment and Control for DFIG Based Wind Turbines during Grid Voltage Sag and Swell Conditions

  • Xu, Hailiang;Ma, Xiaojun;Sun, Dan
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.235-245
    • /
    • 2015
  • This paper proposes a reactive current assignment and control strategy for a doubly-fed induction generator (DFIG) based wind-turbine generation system under generic grid voltage sag or swell conditions. The system's active and reactive power constrains during grid faults are investigated with both the grid- and rotor-side convertors (GSC and RSC) maximum ampere limits considered. To meet the latest grid codes, especially the low- and high-voltage ride-through (LVRT and HVRT) requirements, an adaptive reactive current control scheme is investigated. In addition, a torque-oscillation suppression technique is designed to reduce the mechanism stress on turbine systems caused by intensive voltage variations. Simulation and experiment studies demonstrate the feasibility and effectiveness of the proposed control scheme to enhance the fault ride-through (FRT) capability of DFIG-based wind turbines during violent changes in grid voltage.