• Title/Summary/Keyword: Reactive Power Generation

Search Result 227, Processing Time 0.029 seconds

Dynamic Model Study for the Analysis of the STATCOM Characteristics (STATCOM의 특성해석을 위한 동적모델 고찰)

  • Kim, S.H.;Won, D.J.;Han, H.G.;Lee, S.K.;Moon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1039-1041
    • /
    • 1999
  • Recently Advanced Static Var Compensators(ASVC) or STATic Synchronous COMpesator(STATCOM) has been considered as a next generation reactive power controller. [2] STATCOM is a voltage source inverter(VSI) based static VAr compensator with only small capacitors on the do side. The main function of the STATCOM is to keep the bus voltage magnitude at the desired value. [1] This paper compares the PAM STATCOM with PWM STATCOM. The characteristics and the control method of each model is analyzed. And the simulation of STATCOMs based on the above two methods was presented.

  • PDF

The Dynamic Characteristics Analysis of the STATCOM According to the Realization of the STATCOM Output Voltage (STATCOM의 출력전압 구현방식에 따른 동특성 해석)

  • Kim, Seon-Ho;Won, Dong-Jun;Han, Hak-Geun;Lee, Song-Geun;Mun, Seung-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.7
    • /
    • pp.323-331
    • /
    • 2000
  • Recently Advanced Static Var Compensators(ASVC) or STATic Synchronous COMpesator(STATCOM) has been considered as a next generation reactive power controller. The STATCOM is a voltage source inverter(VSI) based on the static VAr compensator with only small capacitors on the dc side. The main function of the STATCOM is to keep the bus voltage magnitude at the desired value. This paper compared the PAM STATCOM with the PWM STATCOM. The characteristics and the control method of each model is analyzed. And the simulation of STATCOMs based on the above two methods is presented.

  • PDF

A Computation of Efficient Generation Voltage for Reactive Power Market (무효전력시장 구축을 위한 효율적인 발전전압 결정에 관한 연구)

  • Jung, Seung-Wan;Song, Sung-Hwan;Yoon, Yong-Tae;Moon, Seung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.201-203
    • /
    • 2004
  • 본 논문에서는 먼저 유효전력 시장과 무효전력 시장을 분리하여 운영한다는 가정하에서 발전기의 무효전력 생산을 위한 최적의 전압값을 산정하고자 한다. 유효전력 시장에서 경제 급전(Economic Dispatch)을 통해 발전기의 유효전력 생산 비용을 최소화시키는 최적의 유효전력량 결정원리를 응용하여, 무효전력 시장에서의 발전기의 무효전력 생산 비용을 최소화시키는 최적의 발전기 전압 profile을 결정하는 무효전력시장 구축 알고리즘을 제시한다. 이 알고리즘에는 기본적으로 주효전력-전압의 조류방정식과 목적함수로서 무효진력 비용의 최소화 문제, 그리고 부하측 전압과 관련된 부등식제약조건의 선형화 문제 등이 포함된다. 이렇게 산출된 발전전압에 의한 무효전력의 가격은 실제 전압제어에 의한 가격산정이라는 측면에서 그 의미를 찾아볼 수가 있다.

  • PDF

Study on the Generation of Chemically Active Species Using Gas-liquid Mixing Plasma Discharging System (기-액 혼합 플라즈마 방전 시스템에서 화학적 활성종의 생성)

  • Kim, DongSeog;Park, YoungSeek
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.4
    • /
    • pp.394-402
    • /
    • 2014
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and oxygen flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the 2nd voltage (4 kV to 15 kV) was increase, RNO degradation was increased and, generated $H_2O_2$ and $O_3$ concentration were increased. The conductivity of the solution was not influencing the RNO degradation, $H_2O_2$ and $O_3$ generation. The pH effect on RNO degradation was not high. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.

Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop (Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구)

  • Lee, K.O.;Choi, J.Y.;Choy, I.;Jung, Y.S.;Yu, G.Y.;Song, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

Equivalent Grid Impedance Estimation Method Using Negative Sequence Current Injection in Three-Phase Grid-connected Inverter (3상 계통 연계형 인버터의 역상분 전류 주입을 이용한 계통 등가 임피던스 추정 기법)

  • Park, Chan-Sol;Song, Seung-Ho;Im, Ji-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.526-533
    • /
    • 2015
  • A new algorithm is proposed for the estimation of equivalent grid impedance at the point of common coupling of a grid-tie inverter output. The estimated impedance parameter can be used for the improvement of the performance and the stability of the distributed generation system. The estimation error is inevitable in the conventional estimation method because of the axis rotation due to PLL. In the conventional estimation error, the d-q voltage and current are used for the calculation of the impedance with active and reactive current injections. Conversely, in the proposed algorithm, the negative sequence current is injected, and then the negative sequence voltage is measured for the impedance estimation. As the positive and negative sequence current controller is independent and the PLL is based on the positive sequence component only, the estimation of the equivalent impedance can be achieved with high accuracy. Simulation and experimental results are compared to validate the proposed algorithm.

Modeling and Analysis of Control Scheme for Voltage Source Inverter Based Grid-connection of Wind Turbine (전압원인버터를 이용한 계통연계형 풍력발전의 출력제어 모의 및 해석)

  • 김슬기;김응상
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.154-163
    • /
    • 2003
  • Grid connection essentially requires a wind energy conversion system (WECS) to not only supply adequate power responding to constantly varying wind speed but also provide a specified level of voltage magnitude and frequency that is acceptable in the electric power network. To satisfy such requirements, appropriate control schemes of a wind turbine to be connected to the power grid should be employed. This paper presents an output control strategy of a grid-connected wind power generation, which consists of a fixed-pitch wind turbine, a synchronous generator and a AC-DC-AC component with a voltage source inverter built in, and performs modelling and analysis of the strategy using PSCAD/EMTDC, an electromagnetic transient analysis software. Real power output control of the voltage source inverter is implemented to extract the maximum energy from wind speed inputted through wind blades and reactive power control, to keep the terminal voltage of WECS at a specific level. SPWM switching method is used to reduce the harmonics and maintain 60 ㎐ of the output frequency. The wind turbine performance and output corresponding to wind variation and the terminal load change is simulated and analysed.

A Study on Decision Plan of Hosting Capacity for Distribution Feeder (배전선로 연계용량 선정방안에 관한 연구)

  • Kim, Seong-Man;Oh, Joon-Seok;Kim, Ok-Hee;Lim, Hyeon-Ok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.653-660
    • /
    • 2021
  • Renewable energy resources are rapidly becoming an integral part of electricity generation portfolios around the world due to declining costs, government subsidies, and corporate sustainability goal. Interacting wind, solar, and load forecast errors can create significant unpredictable impacts on the distribution system, feeder congestion, voltage standard and reactive power stability margins. These impacts will be increasing with the increasing penetration levels of variable renewable generation in the power systems. There is a limit to the maximum amount of renewable energy sources that can be connected in a distribution feeder by the connection rule of transmission & distribution facility in Korea. This study represents the decision plans of hosting capacity for distribution feeders without the need for significant upgrades to the existing transmission infrastructure. Especially, the paper suggests and discusses the hosting capacity standard of feeder cables and minimum load calculation of distribution feeders.

A Calculation Method for the Nonlinear Crowbar Circuit of DFIG Wind Generation based on Frequency Domain Analysis

  • Luo, Hao;Lin, Mingyao;Cao, Yang;Guo, Wei;Hao, Li;Wang, Peng
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1884-1893
    • /
    • 2016
  • The ride-through control of a doubly-fed induction generator (DFIG) for the voltage sags on wind farms utilizing crowbar circuits by which the rotor side converter (RSC) is disabled has being reported in many literatures. An analysis and calculation of the transient current when the RSC is switched off are of significance for carrying out the low voltage ride through (LVRT) of a DFIG. The mathematical derivation is highlighted in this paper. The zero-state and zero-input responses of the transient current in the frequency domain through a Laplace transformation are investigated, and the transient components in the time domain are achieved. With the characteristics worked out from the linear resolving without modeling simplification, the selection of the resistance in the linear crowbar circuit and the value conversion from a linear circuit to a nonlinear one is proposed to setup the attenuation rate. In terms of grid code requirements, the theoretical analysis for the time constant of the transient components attenuation insures the controllability when the excitation of the RSC is resumed and it guarantees the reserved time for the response of the reactive power compensation. Simulations are executed in MATLAB/SIMPOWER and experiments are carried out to validate the theoretical analysis. They indicate that the calculation method is effective for selection of the resistance in a crowbar circuit for LVRT operations.

Antioxidant and Hepatoprotective Activities of Bitter Melon (Momordica charantia Linn.) Leaves against Oxidative Stress (산화적 스트레스에 대한 여주(Momordica charantia Linn.)잎의 항산화 활성 및 간세포 보호능)

  • Jeon, Ahyeong;Cheon, Wonyoung;Yoon, Jimin;Kim, Dae-Jung;Kim, Younghwa
    • Journal of the Korean Society of Food Culture
    • /
    • v.35 no.6
    • /
    • pp.597-604
    • /
    • 2020
  • This study examined the bioactive compound content and the antioxidant activities of bitter melon (Momordica charantia Linn.) leaves. The content of vitamin C, beta-carotene, and total carotenoids was 69.77, 45.68, and 65.08 mg/100 g, respectively. To investigate the antioxidant capacity, bitter melon leaves were extracted using various concentrations of ethanol (60, 80, or 100%). Highest content of total polyphenols (18.07 mg gallic acid equivalent/g) and flavonoids (4.53 mg cathechin equivalent/g) was found in the 100% ethanolic extract of the leaves (E100). Also, the E100 extract showed the highest levels of 2,2'azino-bis-3-ethylbenzothiazoline-6-sulfonic acid (ABTS) and α-α-diphenyl-β-picrylhydrazyl (DPPH) free radical scavenging activities. Reducing power was also the highest (39.21 mg Trolox equivalent/g) in E100 extract. The E100 extract effectively inhibited lipid peroxidation by 91.45% compared to the control group. Also, the E100 extract showed a cytoprotective effect against oxidative stress in HepG2 cells and decreased the generation of intracellular reactive oxygen species. These results suggest that bitter melon leaves could be regarded as a potential source of natural antioxidants.