Browse > Article
http://dx.doi.org/10.6113/JPE.2016.16.5.1884

A Calculation Method for the Nonlinear Crowbar Circuit of DFIG Wind Generation based on Frequency Domain Analysis  

Luo, Hao (School of Electric Power Engineering, Nanjing Institute of Technology)
Lin, Mingyao (School of Electrical Engineering, Southeast University)
Cao, Yang (Guodian Nanjing Automation Co., Ltd)
Guo, Wei (Guodian Nanjing Automation Co., Ltd)
Hao, Li (School of Electrical Engineering, Southeast University)
Wang, Peng (School of Electric Power Engineering, Nanjing Institute of Technology)
Publication Information
Journal of Power Electronics / v.16, no.5, 2016 , pp. 1884-1893 More about this Journal
Abstract
The ride-through control of a doubly-fed induction generator (DFIG) for the voltage sags on wind farms utilizing crowbar circuits by which the rotor side converter (RSC) is disabled has being reported in many literatures. An analysis and calculation of the transient current when the RSC is switched off are of significance for carrying out the low voltage ride through (LVRT) of a DFIG. The mathematical derivation is highlighted in this paper. The zero-state and zero-input responses of the transient current in the frequency domain through a Laplace transformation are investigated, and the transient components in the time domain are achieved. With the characteristics worked out from the linear resolving without modeling simplification, the selection of the resistance in the linear crowbar circuit and the value conversion from a linear circuit to a nonlinear one is proposed to setup the attenuation rate. In terms of grid code requirements, the theoretical analysis for the time constant of the transient components attenuation insures the controllability when the excitation of the RSC is resumed and it guarantees the reserved time for the response of the reactive power compensation. Simulations are executed in MATLAB/SIMPOWER and experiments are carried out to validate the theoretical analysis. They indicate that the calculation method is effective for selection of the resistance in a crowbar circuit for LVRT operations.
Keywords
Crowbar; Doubly-fed induction generator; Laplace transformation; Voltage sags;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Y. He and P. Zhou, "Overview of the low voltage ride-through technology for variable speed constant frequency doubly fed wind power generation systems," Transactions of China Electrotechnical Society, Vol. 24, No. 9, pp. 140-146, Sep. 2009.
2 J. Morren, and S. W. H. De Haan, "Short-circuit current of wind turbines with doubly-fed induction generator," IEEE Trans. Energy Convers., Vol. 22, No.1, pp. 174-180, Mar. 2007.   DOI
3 J. Zhai, B. Zhang, K. Wang, and W. Shao, "Three-phase symmetrical short circuit current characteristic analysis of doubly fed induction generator with crowbar protection," IEEE PES Innovative Smart Grid Technologies, pp. 1-5, May 2012.
4 H. Soliman, M. I. Marei, R. M. El-Sharkawy, K. M. El-Bahrawy, "Analysis of the dynamic behavior of a DFIG during grid disturbances using active crowbar protection," in 12th International Conference on Environment and Electrical Engineering (EEEIC), pp. 160-163, May 2013.
5 M. Ding, T. Hu, P. Han, and D. Wang, "Analysis of low voltage ride through ability of variable speed constant frequency wind turbine based on crowbar protection," in Asia-Pacific Power and Energy Engineering Conference (APPEEC), pp. 1-5, Mar. 2012.
6 Z. Zheng, G. Yang, and H. Geng, "Short circuit current analysis of DFIG-type WG with crowbar protection under grid fault," in IEEE International Symposium on Industrial Electronics (ISIE), pp. 1072-1079, May 2012.
7 Y. Ren and W. Zhang, "A novel control strategy of an active crowbar for DFIG-based wind turbine during grid fault," in IEEE International Electric Machines & Drives Conference (IEMDC), pp. 1137-1142, May 2011.
8 L. Zhang, X. Jin, and L. Zhan, "A novel LVRT control strategy of DFIG based rotor active crowbar," in Asia-Pacific Power and Energy Engineering Conference (APPEEC), pp. 1-6, Mar. 2011.
9 M. Wang, W. Xu, H. Jia, and X. Yu, "A novel method to optimizing the active crowbar resistance for low voltage ride through operation of doubly-fed induction generator based on wind energy," in IEEE International Symposium on Industrial Electronics (ISIE), pp. 957-962, May 2012.
10 A. Zohoori, J. S. Moghani, S. H. Fathi, and V. Mortezapour, "An optimized crowbar for DFIG with AHP algorithm under single phase fault," in 10th International Conference on Environment and Electrical Engineering (EEEIC), pp. 1-4, May 2011.
11 J. Lopez, E. Gubia, P. Sanchis, and X. Roboam, "Wind turbine based on doubly-fed induction generator under asymmetrical voltage dips," IEEE Trans. Energy Convers., Vol. 23, No. 1, pp. 321-330, Mar. 2008.   DOI
12 G. Pannell, D. J. Atkinson, and B. Zahawi, "Analytical study of grid-fault response of wind turbine doubly fed induction generator," IEEE Trans. Energy Convers., Vol. 25, No. 4, pp. 1081-1091, Dec. 2010.   DOI
13 L. Zhang, X. Cai, and J. Guo. "Dynamic responses of DFIG fault currents under constant AC excitation condition," in Asia-Pacific Power and Energy Engineering Conference, pp. 1-4, Mar. 2009.
14 Z. Wu, G. Wang, H. Li, T. Ding, and X. Gao, "Fault current contribution of DFIG under unsymmetrical fault," in 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), pp. 1687-1692, Jul. 2011.
15 X. Gao, G. Wang, Z. Wu, and H. Li, "Fault current contribution of doubly fed induction generator wind turbines under different control strategies," in International Conference on Advanced Power System Automation and Protection (APAP), Vol. 2, pp. 1209-1214, Oct. 2011.
16 Y. Tang, Y. Zhang, and Y. Fan, Dynamic analysis of AC machine, Chapter. 3, pp. 67-75, China Machine Press, 2004.
17 H. L. Zhou, G. Yang, and D. Y. Li, "Short circuit current analysis of DFIG wind turbine with crowbar protection," in International Conference on Electric Machine and Systems (ICEMS), pp. 1-6, Nov. 2009.