• 제목/요약/키워드: Reactive Method

검색결과 1,517건 처리시간 0.025초

Minimize Reactive Power Losses of Dual Active Bridge Converters using Unified Dual Phase Shift Control

  • Wen, Huiqing;Su, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.654-664
    • /
    • 2017
  • This paper proposed an unified dual-phase-shift (UDPS) control for dual active bridge (DAB) converters in order to improve efficiency for a wide output power range. Different operating modes of UDPS are characterized with respect to the reactive current distribution. The proposed UDPS has the same output power capability with conventional phase-shift (CPS) method. Furthermore, its implementation is simple since only the change of the leading phase-shift direction is required for different operating power range. The proposed UDPS control can minimize both the inductor rms current and the circulating reactive current for various voltage conversion ratios and load conditions. The optimal phase-shift pairs for two bridges of DAB converter are derived with respect to the comprehensive reactive power loss model, including the reactive components delivered from the load and back to the source. Simulation and experimental results are illustrated and explained with details. The effectiveness of the proposed method is verified in terms of reactive power losses minimization and efficiency improvement.

Secondary Voltage Control for Reactive Power Sharing in an Islanded Microgrid

  • Guo, Qian;Wu, Hongyan;Lin, Liaoyuan;Bai, Zhihong;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.329-339
    • /
    • 2016
  • Owing to mismatched feeder impedances in an islanded microgrid, the conventional droop control method typically results in errors in reactive power sharing among distributed generation (DG) units. In this study, an improved droop control strategy based on secondary voltage control is proposed to enhance the reactive power sharing accuracy in an islanded microgrid. In a DG local controller, an integral term is introduced into the voltage droop function, in which the voltage compensation signal from the secondary voltage control is utilized as the common reactive power reference for each DG unit. Therefore, accurate reactive power sharing can be realized without any power information exchange among DG units or between DG units and the central controller. Meanwhile, the voltage deviation in the microgrid common bus is removed. Communication in the proposed strategy is simple to implement because the information of the voltage compensation signal is broadcasted from the central controller to each DG unit. The reactive power sharing accuracy is also not sensitive to time-delay mismatch in the communication channels. Simulation and experimental results are provided to validate the effectiveness of the proposed method.

실시간 디지털 시뮬레이터(Hypersim)을 이용한 이차적 전압제어 제어기 구현 (The realization of secondary voltage controller using real-time digital simulator(Hypersim))

  • 김봉식;서상수;이병준;송인준;신정훈;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.269-271
    • /
    • 2006
  • In power system, the reactive power is closely associated with voltage. In addition Reactive power has localized characteristic. Recently wide area blackout caused by reactive power imbalance. Therefore it is important to control reactive power considering its characteristic. Until now maintenance of system voltage has been controlled by shunt compensation rather than generators. However because of a large time-constant, shunt compensators are difficult to manage disturbances immediately. In addition shunt compensation has discrete characteristic, which make disturbances in system. In this paper we studied the voltage maintenance method of local buses by controlling the reactive power output of a generator which is closely related a load bus in addition the proposed method was verified by test system.

  • PDF

동전기정화 및 투수성반응 복합기술에 의한 오염지반의 복원 (Remediation of contaminated soil by the coupled technique of electrokinetic method and permeable reactive method)

  • 정하익;이명호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.348-351
    • /
    • 2006
  • This paper presents preliminary laboratory investigations on the electrokinetic (EK) remediation coupled with permeable reactive barrier (PRB) system. Atomizing slag was adopted as a PRB reactive material for remediation of groundwater contaminated with inorganic and/or organic substances. A series of laboratory experiments were performed with variable conditions such as (i) type of contaminant, (ii) applied electric field strength, (iii) processing time, and (iv) the application of PRB system. From the preliminary investigations, the coupled technology of EK with PRB system would be effective to remediate contaminated grounds without the extraction of pollutants from subsurface due to the reactions between the reactive materials and contaminants.

  • PDF

한전 계통에서의 무효전력 부하 평가에 관한 연구 (Reactive Power Loadability in Korean Power System)

  • 윤종수;원종률;윤용범;장병훈;이기선;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1472-1474
    • /
    • 1999
  • This paper proposes the estimation method about how much reactive power can be increased or decreased under prescribed bus voltage limits in non-linear reactive power and power flow equations. The static nonlinear reactive power voltage problem can be formulated using a linear resistive(I-V) network with voltage dependent current sources. Linear programming model is derived for finding bounds on reactive power. This method was applied to future Korean power system and proved its effectiveness.

  • PDF

송전손실 상태식별법을 이용한 전압안정성 개선효과의 정량적 평가에 관한 연구 (A Study on the Quantatitive Evaluation of Voltage Stability Improvement Effect By the T/L-Loss System Identification Method)

  • 최종기;이봉용;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.45-47
    • /
    • 1994
  • The simulation of reactive power compensation in 5-bus and 25-bus system was conducted using transmission-line loss system identification method. Sensitivities of maximum load-power with respect to reactive power compensation was identified by the simulation. With sufficient reactive power compensation at the first voltage-collapsing load-bus, the first voltage collapse could be prevented until the next voltage-collapsing load-bus lost its voltage stability. And the total compensated reactive power at the first voltage-collapsing bus means reactive power margin of voltage collapse or distance to voltage collapse. This quantity can be useful for determining the size of compensating devices or the site to compensate.

  • PDF

Effect of Fineness Modulus of Reactive Aggregate on Alkali Silica Reaction

  • Jun, Ssang-Sun;Jin, Chi-Sub
    • International Journal of Concrete Structures and Materials
    • /
    • 제4권2호
    • /
    • pp.119-125
    • /
    • 2010
  • In this study, the effects of the fineness modulus of reactive aggregate on ASR expansion and ASR products have been investigated. The reactive aggregate used was metamorphic aggregate originated from Korea. ASR tests were conducted according to accelerated mortar bar test. The morphology and chemical composition of products formed in mortar bars, 5 years after the mortar bar test had been performed, were studied by scanning electron microscopy equipped with energy dispersive spectroscopy. Test results indicated that ASR expansion of mortar bars decrease in linear proportion to the fineness modulus of reactive aggregate. SEM images indicated that mortar bars showed reactive products formed in cement paste, within air voids and within cracks through particles except for the mortar bar with the fineness modulus of 3.25. The EDS analysis of the reactive products showed presence of silica, calcium and sodium, typical of ASR product composition.

무효전력 기회비용을 반영한 전력시장 입찰전략 연구 (Bidding Strategies with the Opportunity Cost of Reactive Power in a Competitive Market)

  • 이광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권1호
    • /
    • pp.67-72
    • /
    • 2004
  • This paper addresses the bidding strategies of generating firms in a competitive market where the firms are provided with payment for generating reactive power. Reactive support for voltage control is an integral and critical part of power system operations. Since reactive support is unbundled in a competitive market under open access transmission, it is treated as one of ancillary services. The operation costs and opportunity costs for reactive support are compensated by payment to the firms, hence their bidding strategies will be affected. The opportunity costs are evaluated from the foregone profits of a generator in making sales in real power market by providing reactive support instead of real power. Game theory approach is used to analysis the transaction strategies of real power by the bimatrix method in this paper. Through computing the Nash equilibrium in a sample system, an incentive of a generator for improving the reactive generating capacity is found to be effective and the variations of the profits are analyzed as the demand power factor changes.

반응성 골재의 혼입량이 모르타르의 알칼리-실리카 반응 팽창에 미치는 영향 (Effects of Content of Reactive Aggregate on Alkali-Silica Reaction Expansion)

  • 이주현;전쌍순;서기영;진치섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.435-438
    • /
    • 2005
  • The effect of content of reactive aggregate on alkali-silica reaction was investigated through the ASTM C 1260 method. The replacement proportions of fine aggregate by reactive aggregate were 25, 50, 75 and $100\%$, respectively. Reactive aggregate and fine aggregate(non-reactive aggregate) used are a metamorphic rock and andesite rock, respectively. The results indicate that the mortar-bar containing $25\%$ replacement of fine aggregate by reactive aggregate shows the lowest expansion but expansion in excess of $0.1\%$ at 16 days, which can distinguished between deleterious and potentially reactive. Although content of reactive aggregate is a small amount, it can cause detrimental expansion due to alkali-silica reaction.

  • PDF

Canonical Sampling Method for Initial Conditions for Reactive Flux Calculations Using Nose-Hoover Chains

  • Lee, Song-Hi;Pak, Young-Shang
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권4호
    • /
    • pp.533-538
    • /
    • 2004
  • Canonical sampling method has been presented to generate the initial conditions for reactive flux studies of organic reactions in water. Velocity Verlet version of Nose-Hoover chain dynamics algorithm has been employed to sample the initial conditions according to canonical distribution. The unstable normal mode of a transition state has been introduced to define a dividing plane separating reactant and product regions in reaction processes. This method has been implemented and tested for the case iels-Alder reaction of methyl vinyl ketone (MVK) and cyclopentadiene (CPD) in water, providing a reliable tool for further reactive flux molecular dynamics studies in condensed media.