• Title/Summary/Keyword: Reactive Method

Search Result 1,521, Processing Time 0.031 seconds

Real and Reactive power coordination control of Distributed Generation System for Distribution Voltage Regulation (배전계통 적정전압 유지를 위한 유효 무효전력 협조제어)

  • Kim, Tae-Eung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.153-155
    • /
    • 2000
  • This paper reveals some correlations between LDC voltage control method and the output of DGS, and also presents a method for determining the amounts of real, reactive Power of DGS for proper voltage regulation of power distribution system with LDC. Proposed method has been applied to a 22.9 kV class power distribution system, and those results show that the distribution system voltage profile is improved.

  • PDF

Developing a Reactive System Model from a Scenario-Based Specification Model (시나리오 기반 명세 모델로부터 반응형 시스템 모델 개발)

  • Kwon, Ryoung-Kwo;Kwon, Gi-Hwon
    • Journal of Internet Computing and Services
    • /
    • v.13 no.1
    • /
    • pp.99-106
    • /
    • 2012
  • It is an important and a difficult task to analyze external inputs and interactions between objects for designing and modeling a reactive system consisting of multiple object. Also the reactive system is required huge efforts on confirm it can satisfy requirements under all possible circumstances. In this paper, we build from requirements to a scenario-based specification model using LSC(Live Sequence Chart) extending MSC(Message Sequence Chart) with richer syntax and semantic. Then the reactive system model satisfying all requirements for each object in this system can be automatically created through LTL Synthesis. Finally, we propose a method of reactive system development by iterative process transforming a reactive system model to codes.

A Study on Reduction of Reactive Power by PWH Voltage Converter (PWM 전압형 컨버터에 의한 무효전력 보상에 관한 연구)

  • Park, Min-Ho;Choi, Jae-Ho;Kim, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.269-272
    • /
    • 1988
  • This paper introduces a method to reduce the reactive power required by electronic converters. The instantaeous reactive power is calculated and compensated by the current controlled PWH voltage source converter connected parallel between the power lines and the converter. A high performance current control technique which is based on the current deviation vector is used for the PWM converter as compensator of reactive power. Accurate compensation of the reactive power and t control system ensuring fast response to the sudden change of loaf are attained. The converter structure and control scheme are discussed. Simulation of the system is performed.

  • PDF

Stabilization of a Two-link Inverted Pendulum with a Rate Gyro (자이로를 이용한 두 링크 도립진자의 자세안정화)

  • Cho, Baek-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.1
    • /
    • pp.28-34
    • /
    • 2012
  • Human generally uses three methods to keep balance. One of them is using reactive momentum such as swing an upper body or arms. In this study, we proposed a balancing controller for the reactive momentum method using an inverted pendulum. We simplified a human or a humanoid robot as a two-link inverted pendulum having two edges. In addition, we proposed a distinctive condition for controller transition. If a human is pushed, he has to change a balancing controller from using an ankle torque to using a reactive momentum or changing foot placement. When the balancing controller is changed from using an ankle torque to using a reactive momentum, it is required a proper timing to keep a stability and make smooth movement. In the experiment, the proposed controller and distinctive condition were verified.

Adaptive method for the purification of zinc and arsenic ions contaminated groundwater using in-situ permeable reactive barrier mixture

  • Njaramba, Lewis Kamande;Nzioka, Antony Mutua;Kim, Young-Ju
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.283-288
    • /
    • 2020
  • This study investigated the purification process of groundwater contaminated with zinc and arsenic using a permeable reactive barrier with a zero-valent iron/pumice mixture. We determined the removal rates of the contaminants for 30 days. In this study, column reactor filled with the zero-valent iron/pumice reactive mixture was used. Experimental results showed that the mixture exhibited an almost complete removal of the zinc and arsenic ions. Arsenic was removed via co-precipitation and adsorption processes while zinc ions were asorbed in active sites.The purification process of water from the metal ionscontinued for 30 days with constant hydraulic conductivity because of the enhanced porosity of the pumice and interparticle distance between the zero-valent iron and pumice. Contaminants removal rates and the remediation mechanism for each reactive system are described in this paper.

A Method for Calculating Reactive Power Service Charges using Reactive Power Markets (무효전력 시장을 이용한 무효전력요금 산정 방법의 고찰)

  • Sohn, Hyoung-Suk;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.484-487
    • /
    • 2003
  • With the restructuring of the electric power industry during the past decade, operation and control strategies have undergone a shift in paradigm. Certain activities that were earlier considered as part of the integrated electricity supply(such as voltage and frequency control) are now treated as separate services and often independently managed and accounted for. This paper examines the management of reactive power services in deregulated electricity markets around the world. From the review several diverse methods for handling reactive power within the deregulated market framework emerges. While in many of the markets, proper financial compensation mechanisms exist to compensate the providers for their service, some others continue to handle reactive power through regulatory frameworks and technical operation guidelines.

  • PDF

On-line Tests of on the Yang-Yang Pumped Storage Plant for the Reactive Power Limits and the OEL Dynamics (양양양수 온라인 무효전력 운전범위 시험과 과여자제한기(OEL) 동특성 시험)

  • Kim, Dong-Joon;Moon, Young-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1343-1350
    • /
    • 2007
  • This paper describes the tests on the reactive power output limit and the Over-Excitation Limiter (OEL) dynamics of a generation unit. The suggested test methods on reactive limit can identify the allowable maximum/minimum reactive power at 100% rated MW in the steady-state unit operation condition. The on-line OEL test method can identify the time characteristics of OEL with the generation output at 50% of the rated MW. These methods are validated by applying to four Yang-Yang pumped storage units with 282 rated MVA each.

Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement (Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선)

  • Kim, Dong-Uk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.539-547
    • /
    • 2018
  • Grid-connected inverter is required to cut off the power supplied to the grid at the islanding condition, immediately. For this reason, an islanding detection is an indispensable function for grid-connected distributed generation system. Slip-Mode frequency Shift (SMS) islanding detection method is very popular method to determine the grid state. SMS method supplies the reactive power to the load according to the grid frequency. In the islanding condition of grid, this injected reactive power pulls out the grid frequency from the allowable range, then the inverter system can detect the islanding condition of the grid. The SMS method can detect the islanding state well and does not generate any harmonics of the grid current. However, the reactive power would be generated and the power quality is reduced even though the grid is not islanding condition, but normal condition. In this paper, a modified SMS method is proposed to remove the reactive power in the normal condition. The performance of the proposed method is evaluated by 600W single phase inverter experimental results.

STUDY ON THE REAL TIME VOLTAGE-REACTIVE POWER CONTROL USING THE FUZZY THEORY (FUZZY 이론을 이용한 전압.무효전력의 순서제어에 관한 연구)

  • Song, K.Y.;Kim, S.Y.;Cho, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.231-234
    • /
    • 1990
  • This paper shows real-time control technique of voltage-reactive power using the fuzzy theory. Here, major benefits of applying the fuzzy set theory as follow. First, heuristic knowledge of operator has been used in the operation and control of power system. Second, difficulties in traditional multi-objective numerical solution methods have been solved. Also, to achieve optimizing process on the voltage-reactive power control conventional search method have been used.

  • PDF

Harmonic and Reactive power compensation of standby power supply(SPS) using digital controller (디지탈 제어기에 의한 예비전원장치 (SPS)에서의 고조파 및 무효전력보상)

  • Park, Ga-Woo;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.498-501
    • /
    • 1994
  • This paper presents a digital calculation method of instantaneous reactive power component for standby power supply(SPS) system. Reactive current is defined in time domain, calculated instantaneously by using a TMS320C25. The theoretical analysis is verified by the digital simulation and experimental results.

  • PDF