• 제목/요약/키워드: Reactive Fuel

검색결과 121건 처리시간 0.026초

A Study for burning behavior of Hydro-Reactive metal fuel using Ultrasound (초음파를 이용한 해수반응 연료의 연소거동 고찰 연구)

  • Seo, Mu-Kyung;Kang, To;Cho, Seung-Wan;Kim, Hak-Joon;Song, Sung-Jin;Kim, Jun-Hyung;Yoo, Ji-Chang;Jung, Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.451-454
    • /
    • 2011
  • Hydro-Reactive metal Fuel (HRF) which has more fuel than general solid propellant reducing oxidizing agent is suitable for ultrahigh speed rocket motor in the water. However, burning rate of HRF has not been studied yet. Through the earlier studies, we established ultrasonics measurement system measuring burning rate of solid propellant as a function of pressure in a single test and verified its reliability. In this paper, we will measure burning rate of HRF using ultrasound with previous development measurement system.

  • PDF

A Study on the Characteristics of Hydro-reactive Metal Fuel Solid Propellants (수반응 금속연료 고체추진제의 특성연구)

  • Kim, Jun-Hyung;Seo, Tae-Seok;Jung, Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.429-431
    • /
    • 2011
  • The characteristics of hydro-reactive metal fuel(HRF) propellant on motor performances such as specific impulse and chamber temperature were analyzed by thermodynamic calculation methods. The thermal analysis and burning rate experiments of HRF propellants were also carried out for studying effects of metal fuels on combustion properties.

  • PDF

A Knowledge Based System for Reactive Power/Voltage Control Including Contingency (상정사고를 고려한 무효전력/전압제어 전문가 시스템)

  • 박영문;김두현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • 제39권8호
    • /
    • pp.779-791
    • /
    • 1990
  • This paper presents a knowledge based system to solve reactive power/voltage control problem in a power system. A need is recognized for new methods to alleviate a bus voltage limit violation more quickly when a power system becomes an emergency state due to contingency. To cope with this object, a set of indices concept which is used to make bus order list of reactive power injection priority is introduced. A set of indices, based on the overall system conditions, consists of steady state stability index, reactive power transmittance indes, voltage severity index and generator fuel cost index. This scheme and empirical rules of the knowledge on the basis of the human expert result in fast decision-making of the reactive power compensation devices since only the amount of devices is determined by the inference in the knowledge based system when the voltage violation is detected. In this approach, control devices such as shunt capacitor (reactor), transformer tap settings and generator voltages are utilized. Also the developed system herein can be used to minimize control action taken or generator fuel cost according to the user's option on the weighting factor. The results of a case study are also presented.

  • PDF

Feasibility of a methane reduced chemical kinetics mechanism in laminar flame velocity of hydrogen enriched methane flames simulations

  • Ennetta, Ridha;Yahya, Ali;Said, Rachid
    • Advances in Energy Research
    • /
    • 제4권3호
    • /
    • pp.213-221
    • /
    • 2016
  • The main purpose of this work is to test the validation of use of a four step reaction mechanism to simulate the laminar speed of hydrogen enriched methane flame. The laminar velocities of hydrogen-methane-air mixtures are very important in designing and predicting the progress of combustion and performance of combustion systems where hydrogen is used as fuel. In this work, laminar flame velocities of different composition of hydrogen-methane-air mixtures (from 0% to 40% hydrogen) have been calculated for variable equivalence ratios (from 0.5 to 1.5) using the flame propagation module (FSC) of the chemical kinetics software Chemkin 4.02. Our results were tested against an extended database of laminar flame speed measurements from the literature and good agreements were obtained especially for fuel lean and stoichiometric mixtures for the whole range of hydrogen blends. However, in the case of fuel rich mixtures, a slight overprediction (about 10%) is observed. Note that this overprediction decreases significantly with increasing hydrogen content. This research demonstrates that reduced chemical kinetics mechanisms can well reproduce the laminar burning velocity of methane-hydrogen-air mixtures at lean and stoichiometric mixture flame for hydrogen content in the fuel up to 40%. The use of such reduced mechanisms in complex combustion device can reduce the available computational resources and cost because the number of species is reduced.

Effects of Nickel and Iron Oxide Addition by Milling under Hydrogen on the Hydrogen-Storage Characteristics of Mg-Based Alloys

  • Song, Myoung Youp;Baek, Sung Hwan;Park, Hye Ryoung;Mumm, Daniel R.
    • Korean Journal of Metals and Materials
    • /
    • 제50권1호
    • /
    • pp.64-70
    • /
    • 2012
  • Samples of pure Mg, 76.5 wt%Mg-23.5 wt%Ni, and 71.5 wt%Mg-23.5 wt%Ni-5 wt%$Fe_2O_3$ were prepared by reactive mechanical grinding and their hydriding and dehydriding properties were then investigated. The reactive mechanical grinding of Mg with Ni is considered to facilitate nucleation and to shorten diffusion distances of hydrogen atoms. After hydriding-dehydriding cycling, the 76.5 wt%Mg-23.5 wt%Ni and 71.5 wt%Mg-23.5 wt%Ni-5 wt%$Fe_2O_3$ samples contained $Mg_2Ni$ phase. In addition to the effects of the creation of defects and the decrease in particle size, the addition of Ni increases the hydriding and dehydriding rates by the formation of $Mg_2Ni$. Expansion and contraction of the hydride-forming materials (Mg and $Mg_2Ni$) with the hydriding and dehydriding reactions are also considered to increase the hydriding and dehydriding rates of the mixture by forming defects and cracks leading to the fragmentation of particles. The reactive mechanical grinding of Mg-Ni alloy with $Fe_2O_3$ is considered to decrease the particle size.

The Characteristics of the Flame Propagation Velocity and Volume Integral of Reaction Rate with the Variation of Fuel Injection Velocity for a Liftoff Flame (부상화염에서 연료유량에 따른 화염전파속도와 체적연소반응속도의 변화 특성에 관한 연구)

  • Ha, Ji-Soo;Kim, Tae-Kwon;Park, Jeung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권4호
    • /
    • pp.466-475
    • /
    • 2009
  • A numerical analysis of reactive flow in a liftoff flame is accomplished to elucidate the characteristics of flame propagation velocity and volume integral of reaction rate with the variation of fuel injection velocity at the fuel rich region, fuel lean region and diffusion flame region. The increase of fuel injection velocity enhances flame propagation velocity, but its effect on the flame propagation velocity is not much greater under 4%. The increase of fuel injection velocity affects directly and linearly on the flame surface area in the fuel rich region and so enhances volume integral of reaction rate to accommodate the increment of fuel.

Experimental and Numerical Investigation for NOx Reduction with Fuel Lean Reburning System (NOx저감을 위한 연료희박 재연소 기법의 실험 및 수치적 연구)

  • Kim, Hak-Young;Baek, Seung-Wook;Son, Hee;Kim, Se-Won
    • Journal of the Korean Society of Combustion
    • /
    • 제14권2호
    • /
    • pp.18-25
    • /
    • 2009
  • Fuel lean reburning method is very attractive way in comparison with conventional reburning method for reducing NOX. Meanwhile, the knowledge of the how flue gas re-circulated, temperature distribution and species concentration is crucial for the design and operation of an effective fuel lean reburning system. For this reason, numerical analysis of fuel lean reburning system is a very important and challenge task. In this work, the effect of fuel lean reburn system on NOX reduction has been experimentally and numerically conducted. Experimental study has been conducted with a 15kW lab scale furnace. Liquefied Petroleum Gas is used as main fuel and reburn fuel. To carry out numerical study, the finite-volume based commercial computational fluid dynamics (CFD) code FLUENT6.3 was used to simulate the reacting flow in a given laboratory furnace. Steady state, three dimensional analysis performed for turbulent reactive flow and radiative heat transfer in the furnace.

  • PDF

Determining the Reference Voltage of 345 kV Transmission System Considering Economic Dispatch of Reactive Power (무효전력 경제급전을 고려한 345㎸ 송전계통의 기준 전압 설정 방법)

  • Hwang, In-Kyu;Jin, Young-Gyu;Yoon, Yong-Tae;Choo, Jin-Boo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제67권5호
    • /
    • pp.611-616
    • /
    • 2018
  • In the cost based pool market in Korea, there is no compensation of reactive power because the fuel cost for reactive power is relatively low compared to that of active power. However, the change of energy paradigm in the future, such as widespread integration of distributed renewable energy source, will prevent the system operator from mandating the reactive power supply without any compensation. Thus, in this study, we propose the reference voltage of the 345 kV transmission system that minimizes the reactive power supply. This is closely related to the economic dispatch of reactive power aiming at minimizing the compensation cost for the reactive power service. In order to verify the effectiveness of the proposed reference voltage, the simulations are performed using the IEEE 14 bus system and the KEPCO real networks. The simulation results show that a voltage lower than the current reference value is recommended to reduce the reactive power supply and also suggest that the current voltage specification for the 345 kV system needs to be reviewed.

The Modeling of Power conversion system with PEM fuel cell (연료전지를 이용한 전력변환장치 시스템 모델링)

  • Han, Kyung-He;Kwon, Sam-Yung;Park, Hyun-June;Lee, Byung-Song;Baek, Soo-Hyun
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1984-1989
    • /
    • 2008
  • A powered system with fuel cell is regarded as a high current and low voltage source. Effects of the loads on the electrical power source are important to optimize the integrated power system. The design parameters of the system should be chosen by taking into account the characteristics of the fuel cell, so the costs of the power system at given operating conditions can be reduced. Furthermore, the dynamics characteristic of the system is crucial to acquire performance in applications, particularly interactions between loads and the fuel cell system. Currently, no integrated simulation has been approached to analyze interrelated effects. Therefore, the dynamic models of power conversion system with a PEM fuel cell that includes the PEM fuel cell stack, DC/DC converter and associated controls is developed. Electric lads for the system are derived by using a power theory that separates a load current into active, reactive, distortion or a mixed current component. Dependency of the DC capacitor on the loads are analyzed.

  • PDF

An Improved Anti-Islanding Algorithm for Utility Interconnection of Multiple Distributed Fuel Cell Powered Generations

  • Jeraputra Chuttchaval;Hwang In-Ho;Choi Se-Wan;Aeloiza Eddy C.;Enjeti Prasad N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.192-199
    • /
    • 2006
  • This paper presents an improved anti-islanding algorithm for utility interconnection of multiple distributed fuel cell powered generations (DFPGs). A cross-correlation method is proposed and implemented in conjunction with the anti-islanding algorithm developed in the previous work [I]. While the power control algorithm continuously perturbs $({\pm}5%)$ the reactive power supplied by the DFPG, the proposed algorithm calculates the cross-correlation index of a rate of change of the frequency deviation with respect to $({\pm}5%)$ the reactive power to confirm islanding. If this index is above 50%, the algorithm further initiates $({\pm}10%)$ the reactive power perturbation and continues to calculate the correlation index. If the index exceeds 80%, the occurrence of islanding can be confirmed. The proposed method is robust and capable of detecting the occurrence of islanding in the presence of several DFPGs, which are independently operating. Viability of the cross-correlation method is verified by the simulation. Experimental results are presented to support the findings of the proposed method.