• Title/Summary/Keyword: Reactive Case

Search Result 524, Processing Time 0.028 seconds

Film Properties of TiO2 Made by Activated Reactive Evaporation (활성화 반응으로 제작된 TiO2의 박막특성)

  • Park, Yong-Gwon;Choi, Jae-Ha
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.3
    • /
    • pp.151-154
    • /
    • 2001
  • $TiO_2$ thin film has wide application because of its high capacitanca, reflection, and good transmissivity in visible range. $TiO_2$ thin film can be made by thermal deposition method, reactive evaporation method, activated reactive evaporation(ARE) method. In the case of thermal deposition, the oxygen deficiency can occur because the melting point of Ti is very high. While in the case of reactive evaporation, high density $TiO_2$ can not be made, because reactive gas($O_2$) and evaporated material(Ti) are not fully combined, activated reactive evaporation, $TiO_2$ is easily deposited at lower gas pressure compared with reactive evaporation because the ionized reactive gas is made by plasma. Therefore, activated reactive evaporation is very useful to deposit the material having the high melting point. In this work, we formed $TiO_2$ thin film by activated reactive evaporation method. The surface of $TiO_2$ thin film was analyzed by X-ray photoelectron spectroscopy. The surface morphology which was analyzed by atomic force microscopy(AFM) shows that feature of the film surface is uniform. The dielectric capacitance, withstanding voltage were $600{\mu}F/cm^2$, 0.4V respectively. In further work, we can increase the withstanding voltage by improving the deposition parameter of substrates.

  • PDF

A case of reactive arthritis after Salmonella enteritis in in a 12-year-old boy

  • Chun, Peter;Kim, Young-Jin;Han, Young-Mi;Kim, Young-Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.7
    • /
    • pp.313-315
    • /
    • 2011
  • Reactive arthritis comprises a subgroup within infection-associated arthritides in genetically susceptible hosts. Researchers and clinicians recognize two clinical forms of reactive arthritis which occurs after genitourinary tract infection and after gastrointestinal tract infection. Chlamydia infection has been implicated as the most common agent associated with post-venereal reactive arthritis. Studies have proposed Shigella infection, Salmonella infection, or Yersinia infection as the microorganisms responsible for the post-dysenteric form. The human leukocyte antigen (HLA)-B27 antigen is the best-known predisposing factor. We report a case of HLA-B27-associated reactive arthritis after Salmonella enteritis at Pusan National University hospital.

Active/Reactive Compound Compensation in Distribution System

  • Sul, Yong-Tae
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.46-52
    • /
    • 1997
  • In this paper th use of compensation based on a combination of active plus reactive power at distribution model system is proposed. The basic voltage-power relationships for the linearized case on an infinite bus are used and the compensation angle is defined based on the voltage magnitude response to small power injection. Compensation is supplied at several locations, and the system is subjected to varying fault scenarios, with its response observed under different system conditions. As number of control issues for a storage-based active/reactive power compensator as a bus voltage regulator are explored to compare the effectiveness of active/reactive again reactive-only compensation.

  • PDF

Optimum Allocation of Reactive Power in Real-Time Operation under Deregulated Electricity Market

  • Rajabzadeh, Mahdi;Golkar, Masoud A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.337-345
    • /
    • 2009
  • Deregulation in power industry has made the reactive power ancillary service management a critical task to power system operators from both technical and economic perspectives. Reactive power management in power systems is a complex combinatorial optimization problem involving nonlinear functions with multiple local minima and nonlinear constraints. This paper proposes a practical market-based reactive power ancillary service management scheme to tackle the challenge. In this paper a new model for voltage security and reactive power management is presented. The proposed model minimizes reactive support cost as an economic aspect and insures the voltage security as a technical constraint. For modeling validation study, two optimization algorithm, a genetic algorithm (GA) and particle swarm optimization (PSO) method are used to solve the problem of optimum allocation of reactive power in power systems under open market environment and the results are compared. As a case study, the IEEE-30 bus power system is used. Results show that the algorithm is well competent for optimal allocation of reactive power under practical constraints and price based conditions.

3-D simulator for development of reactive/deliberative hybrid autonomous robot architecture (자율로봇을 위한 reactive/deliberative hybrid 제어 구조 개발을 위한 3차원 시뮬레이터)

  • Yoon, Do-Young;Kim, Young-Chul;Oh, Sang-Rok;Park, Gwi-Tae;Cho, Woong-Ryul;Suh, Il-Hong;Kim, Kwang-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2880-2882
    • /
    • 2000
  • In the case of designing autonomous robot architecture using deliberative and reactive control methods, we can use mixed hybrid form as well as purely reactive scheme or purely deliberative scheme respectively according to its own goal and environment within the robot operates, It needs time and endeavors to design robot control architecture in either case above. In our research, we implemented a 3-dimensional robot simulator in order to help designing reactive/deliberative autonomous robot control architecture by offering methods which is capable of selecting design parameters and confirming its performances. It can be used, of course, to design purely reactive or purely deliberative architecture. The architecture and performance of simulator is shown and a sample hybrid robot architecture designed with the simulator is introduced in this article.

  • PDF

Dye-resist Properties of Reactive Dye-resist Agents in Reactive Dyeing of Silk

  • Park, Sung-Hee;Oh, Myung-Joon;Koh, Joon-Seok
    • Textile Coloration and Finishing
    • /
    • v.19 no.5
    • /
    • pp.8-16
    • /
    • 2007
  • The dye-resist effect of reactive dye-resist agents in reactive dyeing of silk was investigated. The dichlorotriazine-based dye-resists achieved a higher effectiveness than others since they make a charge barrier of diffusion in the silk fiber periphery due to high reactivity of dichlorotriazine group. Similarly, in the case of hetero-multifunctional dye-resist agent, the dye-resist agent containing both a dichlorotriazine and an ${\alpha}$-bromoacrylamide reactive groups achieved better resist effectiveness than those containing both a monochlorotriazine and an ${\alpha}$-bromoacrylamide groups. Also, their resist effectiveness was improved by increasing the number of sulfonate groups in the dye-resist agents and the number of reactive groups in the reactive dyes applied to them.

The Effects of Intermediate Drying after Padding on the Resist-Discharge Printing of Cotton Fabrics with Reactive/Reactive Dyes (패딩 후 중간건조가 반응/반응염료에 의한 면직물 방발염에 미치는 영향)

  • Park, Geon Yong
    • Textile Coloration and Finishing
    • /
    • v.7 no.4
    • /
    • pp.33-38
    • /
    • 1995
  • In resist-discharge printing of cotton fabrics with reactive/reactive dyes the effects of intermediate drying on the white and the colored resist-dischargeabilities were studied. From the results of resist-discharge printing in case of 75% pick up, it was found that the most effective condition of intermediate drying which could at once prevent bleeding and improve the resist-dischargeability was 11$0^{\circ}C$ x 1min. The drying condition of 10$0^{\circ}C$ x 2min or 12$0^{\circ}C$ x 1min can be also recommended. It is important to pay close attention to the intermediate drying temperature and time. Because in case of 75% pick up when drying was carried on at 11$0^{\circ}C$ or 12$0^{\circ}C$ for more than 1 minute the resist-dischargeability was greatly lowerd by the fast fixation of ground color caused by high temperature, and in case of 100 % pick up the insufficient drying of ground color caused the resist-dischargeability to lower with giving rise to various troubles such as bleeding and smearing.

  • PDF

Assessing pollutants' migration through saturated soil column

  • Smita Bhushan Patil;Hemant Sharad Chore;Vishwas Abhimanyu Sawant
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.95-106
    • /
    • 2023
  • In the developing country like India, groundwater is the main sources for household, irrigation and industrial use. Its contamination poses hydro-geological and environmental concern. The hazardous waste sites such as landfills can lead to contamination of ground water. The contaminants existing at such sites can eventually find ingress down through the soil and into the groundwater in case of leakage. It is necessary to understand the process of migration of pollutants through sub-surface porous medium for avoiding health risks. On this backdrop, the present paper investigates the behavior of pollutants' migration through porous media. The laboratory experiments were carried out on a soil-column model that represents porous media. Two different types of soils (standard sand and red soil) were considered as the media. Further, two different solutes, i.e., non-reactive and reactive, were used. The experimental results are simulated through numerical modeling. The percentage variation in the experimental and numerical results is found to be in the range of 0.75- 11.23 % and 0.84 - 1.26% in case of standard sand and red soil, respectively. While a close agreement is observed in most of the breakthrough curves obtained experimentally and numerically, good agreement is seen in either result in one case.

Development of Generator Reactive Capability Test Method in Generation Stations (발전기 무효전력 성능시험 절차 개발)

  • Shin, Man-Su;Jeong, Tae-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.936-941
    • /
    • 2011
  • Generation cooperations have focused on active power directly related to economic value. So, utility cooperation have taken expense to stabilize power system, although generator has responded quickly with variation of power system voltage and is controlled at real time. As a reactive power source, it is necessary for generator's capabilities to be verified. But domestic generators scarcely have been tested and operated to reactive power capability. In case of power system fault, operators would not quickly take a follow-up actions about reactive power disturbance. Therefore generator reactive power capability verification strategy must be developed, several generators is tested as examples since 2004. This paper is extracted from the test results.

Reactive Power Capability Verification Strategy (발전기 무효전력 성능시험 절차서 정립)

  • Shin, Man-Su;Lee, Ju-Hyun;Lim, Ick-Heon;Ryu, Ho-Seon;Shin, Jung-Seon;Byun, Seong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.87-88
    • /
    • 2006
  • Generator has responded quickly with variation of power system voltage and is controlled at real time. As a reactive power source, generator is revalued better than power condenser and as a reactive power sink, is revalued. But Domestic generators scarcely have been tested and operated to reactive power capability. In case of power system fault, operators wouldn't quickly take a follow-up measures about reactive power disturbance. Therefore generator reactive power capability verification strategy must be developed, several generators is tested as a exhibition since 2004. This paper is extract from the test contents.

  • PDF