• 제목/요약/키워드: Reaction Accuracy

Search Result 396, Processing Time 0.021 seconds

RELATIONSHIP BETWEEN CHANGES IN EVENT-RELATED POTENTIALS AND CHANGES IN CONTINUOUS PERFORMANCE TEST UNDER THE INFLUENCE OF METHYLPHENIDATE IN ATTENTION-DEFICIT/HYPERACTIVITY DISORDER (주의력 결핍 ${\cdot}$ 과잉행동장애 아동에서 Methylphenidate에 의한 사건관련전위와 연속과제수행 변화사이의 상관성)

  • Choi, Young;Lee, Mu-Suk;Lee, Mi-Suk
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.273-286
    • /
    • 1997
  • Objective:This study was designed to evaluate effects of methylphenidate(MPH) on event-related potentials(ERP) and continuous performance test(CPT) in attention-deficit hyperactivity disorder (ADHD) and to see the correlation between changes in ERP and changes in performance. Method:ERP and CPT were used to examine the acute effects of MPH(0.5mg/kg) in eleven ADHD boys(89-103 months old). Results:1) After MPH administration, P3 latency to nontarget stimuli at Fz was significantly decreased (p<0.01) and P2 amplitudes to target stimuli at Pz and at Oz and P3 amplitude to target stimuli at Cz were significantly increased(p<0.05). 2) Commission error and omission error in the CPT-X and commission error in the CPT-AX were decreased(p<0.01), and hits and perceptual sensitivity(d') in the CPT-X and d′ in the CPT-AX were increased(p<0.01). 3) The change of P3 latency to nontarget stimuli at Fz and the change of d′ in the CPT-X were negatively correlated(p<0.05), and the change of P2 amplitude to target stimuli at Pz and d′ in the CPT-AX were positively correlated(p<0.05). Conclusion:MPH improves change orienting reaction, the delivery of task relevant information, accuracy and perceptual sensitivity in ADHD. And the increase of ability to discriminate targets from non-targets reflects reduced evaluation time in large memory component task and enhanced change orienting reaction in simple task.

  • PDF

Preimplantation Genetic Diagnosis for Single Gene Disorders (단일 유전자 질환에 대한 착상전 유전진단)

  • Lee, Hyoung-Song;Kim, Min-Jee;Kang, Inn-Soo
    • Journal of Genetic Medicine
    • /
    • v.6 no.2
    • /
    • pp.131-145
    • /
    • 2009
  • Preimplantation genetic diagnosis (PGD) has become an assisted reproductive technique for couples who are at risk that enables them to have unaffected baby without facing the risk of pregnancy termination after invasive prenatal diagnosis. The molecular biology and technology for single-cell genetics has reached an extremely high level of accuracy, and has enabled the possibility of performing multiple diagnoses on one cell using whole genome amplification. These technological advances have contributed to the avoidance of misdiagnosis in PGD for single gene disorders. Polymerase chain reaction (PCR)-based PGD will lead to a significant increase in the number of disorders diagnosed and will find more widespread use, benefiting many more couples who are at risk of transmitting an inherited disease to their baby. In this review, we will focus on the molecular biological techniques that are currently in use in the most advanced centers for PGD for single gene disorders, including biopsy procedure, multiplex PCR and post-PCR diagnostic methods, and multiple displacement amplification (MDA) and the problems in the single cell genetic analysis.

  • PDF

Validation of the LC-MS/MS Method for Ginsenoside Rb1 Analysis in Human Plasma (LC-MS/MS를 이용한 인체 혈장에서 Ginsenoside Rb1의 분석법 검증)

  • Han, Song-Hee;Kim, Yunjeong;Jeon, Ji-Young;Hwang, Minho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1753-1757
    • /
    • 2012
  • A new liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay for the quantification of ginsenoside Rb1 in human plasma was developed and validated. The separation was performed on a Agilent C18 column ($4.6mm{\times}150mm$, particle size 5 ${\mu}m$) with a gradient elution of 0.1% formic acid in water and 0.1% formic acid in methanol and a flow rate of 0.9 mL/min. The analyte was determined using electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode (m/z 1131.714${\rightarrow}$365.303). Human plasma samples were extracted with acetone : water (50:50) by the liquid-liquid extraction method. The method was linear over the dynamic range of 10~500 ng/mL with a correlation coefficient of r=0.9995. The intra-and inter-day precision over the concentration range of ginsenoside Rb1 was lower than 5.8% (correlation of variance, CV), and the accuracy was between 96.0~104.6%. This LC-MS/MS assay of ginsenoside Rb1 in human plasma is applicable for quantification in a pharmacokinetic study.

Alternative Immunossays

  • Barnard, G.J.R.;Kim, J.B.;Collins, W.P.
    • Korean Journal of Animal Reproduction
    • /
    • v.9 no.2
    • /
    • pp.133-139
    • /
    • 1985
  • An immunoassay may be defined as an analytical procedure involving the competitive reaction between a limiting concentration of specific antibody and two populations of antigen, one of which is labelled or immobillized. The advent of immunoassay has revolutionised our knowledge of reproductive physiology and the practice of veterinary and clinical medicine. Radioimmunoassay (RIA) was the first of these methods to be developed, which meausred the analyte with good sensitivity, accuracy and precision (1,2). The essential components of RIA are:-(i) a limited concentration of antibodies, (ii) a reference preparation, and (iii) an antigen labelled with a radioisotope (usually tritium or iodine-125). Most procedures invelove isolating the antibody-bound fraction and measuring the amount of labelled antigen. Good facilities are available for scintilltion counting, data reduction nd statistical analysis. RIA is undergoing refinement through:-(i) the introduction of new techniques to separate the antibody-bound and free fractions which minimize the misclassification of labelled antigen into these compartments, and the amount of non-specfic binding. (3), (ii) the development of non-extration for the measurement of haptens (4), (iii) the determination of a, pp.rent free (i.e. non-protein bound) analytes (5), and (iv) the use of monoclonal antibodies(6). In 1968, Miles and Hales introduced in important new type of immunoassay which they termed immunora-diometric assay (IRMA) based on t도 use of isotopically labelled specific antibodies(7) in a move from limited to excess reagent systems. The concept of two-site IRMAs (with a capture antibody on a solid-phase, and a second labelled antibody to a different antigenic determinant of the analyte) has enabled the development of more sensitive and less-time consuming methods for the measurement of protein hormones ovar wide concentration of analyte (8). The increasing use of isotopic methos for diverse a, pp.ications has exposed several problems. For example, the radioactive half-life and radiolysis of the labelled reagent limits assay sensitivity and imposes a time limit on the usefulness of a kit. In addition, the potential health hazards associated with the use and disposal of radioactive cmpounds and the solvents and photofluors necessary for liquid scientillation counting are incompatable with the development of extra-laboratory tests. To date, the most practical alternative labels to radioisotopes, for the measurement of analytes in a concentration > 1 ng/ml, are erythrocytes, polystyrene particiles, gold sols, dyes and enzymes or cofactors with a visual or colorimetric end-point(9). Increased sensitivity to<1 pg/ml may be obtained with fluorescent and chemiluminescent labels, or enzymes with a fluorometric, chemiluminometric or bioluminometric end-point. The sensitivity of any immunoassay or immunometric assay depends on the affinity of the antibody-antigen reaction, the specific activity of the label, the precision with which the reagents are manipulated and the nonspecific background signal (10). The sensitivity of a limited reagent system for the measurement of haptens or proteins is mainly dependent upon the affinity of the antibodies and the smalleest amount of reagent that may be manipulated. Consequently, it is difficult in practice to improve on the sensitivity obtained with iodine-125 as the label. Conversely, with excess reagent systems for the measurement of proteins it is theoretically possible to increase assay sensitivity at least 1000 fold with alternative luminescent labels. To date, a 10-fold improvement has been achieved, and attempts are being made to reduce the influence of other variables on the specific signal from the immunoreaction.

  • PDF

Determination of lercanidipine in human plasma by LC-MS/MS (LC-MS/MS를 이용한 혈장 중 레르카니디핀의 분석)

  • Jang, Moon-Sun;La, Sookie;Chang, Kyu Young;Kang, Seung Woo;Han, Sang Beom;Lee, Kyung Ryul;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of lercanidipine in human plasma. After addition of internal standard (amlodipine), plasma was precipitated with acetonitrile and the supernatant was evaporated. The residues were dissolved in 50 % acetonitrile and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring(MRM) mode, lercanindipine were selectively detected without severe interference from human plasma. The standard calibration curve for lercanidipine was linear (r = 0.9994) over the concentration range 0.05-20.0 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of lercanidipine was lower than 11.7 % (correlation of variance, CV), and accuracy was between 94.4-114.8 %. This method has been successfully applied to the pharmacokinetic study of lercanidipine in human plasma.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Characterizing Information Processing in Visual Search According to Probability of Target Prevalence (표적 출현확률에 따른 시각탐색 정보처리 특성)

  • Park, Hyung-Bum;Son, Han-Gyeol;Hyun, Joo-Seok
    • Korean Journal of Cognitive Science
    • /
    • v.26 no.3
    • /
    • pp.357-375
    • /
    • 2015
  • In our daily life, the probability of target prevalence in visual search varies from very low to high. However, most laboratory studies of visual search used a fixed probability of target prevalence at 50%. The present study examined the properties of information processing during visual search where the probability of target prevalence was manipulated to vary from low (20%), medium (50%), to high (80%). The search items were made of simple shape stimuli, and search accuracy, signal detection measures, and reaction times (RTs) were analyzed for characterizing the effect of target prevalence on the information processing strategies for visual search. The analyses showed that the rates of misses increased whereas those of false alarms decreased in the search condition of low target prevalence, whereas the pattern was reversed in the high prevalence condition. Signal detection measures revealed that the target prevalence shifted response criterion (c) without affecting sensitivity (d'). In addition, RTs for correct rejection responses in the target-absent trials became delayed as the prevalence increased, whereas those for hits in the target-present trials were relatively constant regardless of the prevalence. The RT delay in the target-absent trials indicates that increased target prevalence made the 'quitting threshold' for search termination more conservative. These results support an account that the target prevalence effect in visual search arises from a shift of decision criteria and the subsequent changes in search information processing, while rejecting the account of a speed-accuracy tradeoff.

Structure and physical properties of the earth crustal material in the middle of Korean Peninsula : A study on the prescription of standard test by mortar-bar method (한반도 중부권 지각물질의 구조와 물성연구 : 콘크리트 공시체에 의한 표준시험 규정에 대하여)

  • 정진곤;유신애
    • The Journal of Engineering Geology
    • /
    • v.5 no.2
    • /
    • pp.193-200
    • /
    • 1995
  • It has been well known that the alkali-aggregate reaction between the aggregates and cement paste is one of the reasons of a concrete siructre expansion. Because of a serious demage on the concrete stnicture from the expansion, in many countries, the safety of the materials is checked in laboratory by mortar-bar test and the upper limit of expansion in length is 0.1%. The prescriptions are presented in the ASTM C227 and 490 of U.S. which has been international currency and in the KS Handbook F2503, F2546 and L5107 of Korea published by Korean Standards Association. Both of the prescriptions are almost same in their contents. Actually, in the process of preparing and measuring the mortar-bar according to the prescription mentioned above, it seems that there are no problems for its own purpose but a few points are found to be improved upon the methods to increase the accuracy for laboratory work as follows. 1. The prescription of blending ratio(aggregate, cement and water) should be noted by volume not by weight. 2. It is unreasonable to measure the initial length of mortar bars after 24$\pm$2 hours at once regardless the kind of aggregates. 3. It may bring about errors in calculating the expansion ratio under the condition of the denominator value fixed as 254mm. 4. The measuring methods of specific gravity are selected according to the purposes but the pure specific gravity displays the highest accuracy among them.

  • PDF

Abnormal Response Analysis of a Cable-Stayed Bridge using Gradual Bilinear Method (Gradual Bilinear Method를 이용한 사장교의 케이블 손상응답 해석)

  • Kim, Byeong-Cheol;Park, Ki-Tae;Kim, Tae-Heon;Hwang, Ji-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.60-71
    • /
    • 2014
  • Cable-stayed bridge, which is one of the representative long-spanned bridge, needs prompt maintenances when a stay cable is damaged because it may cause structural failure of the entire bridge. Many researches are being conducted to develop abnormal behavior detection algorithms for the purpose of shortening the reaction time after the occurrence of structural damage. To improve the accuracy of the damage detection algorithm, ample observation data from various kinds of damage responses is needed. However, it is difficult to measure an abnormal response by damaging an existing bridge, numerical simulation can be an effective alternative. In most previous studies, which simulate the damage responses of a cable-stayed bridge, the damages has been considered as a load variation without regard to its stiffness variation. The analyses of using these simplification could not calculate exact responses of damaged structure, though it may reserve a sufficient accuracy for the purpose of bridge design. This study suggests Gradual Bilinear Method (GBM) which simulate the damage responses of cable-stayed bridge considering the stiffness and mass variation, and develops an analysis program. The developed program is verified from the responses of a simple model. The responses of a existing cable-stayed bridge model are analyzed with respect to the fracture delay time and damage ratio. The results of this study can be used to develop and verify the highly accurate abnormal behavior detection algorithm for safety management of architecture/large structures.

Determination of Nitrovin in Fishery Products by Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 니트로빈의 정량분석법 개발 및 검증)

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.118-123
    • /
    • 2018
  • The objective of this study was to develop a sensitive method for the identification and determination of nitrovin in fishery products by using a solid-phase extraction (SPE), as performed with a liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted with a mixture of acetonitrile and water, and were then defatted with acetonitrile saturated hexane, after which further clean-up was accomplished with SPE on the hydrophilic-lipophilic balance (HLB) cartridges. The analytes were subsequently ionized in the positive mode of an electrospray ionization (ESI), and where thereby detected in a process of multiple reaction monitoring (MRM). The linearity (expressed as correlation coefficients) of the matrix calibration curves was > 0.985. The limit of the quantification for the nitrovin was measured at 0.001 mg/kg. The accuracy (expressed as average recovery) was noted between 72.1 and 122%. The precision (expressed as coefficient variation) was noted from 2.9 to 16.9%. According to the CODEX CAC/GL-71 guideline accuracy, precision, linearity, and limit of detection were determined in three matrices (which were flatfish, eel and shrimp). The proposed method was suitable for analyzing the associated nitrovin residues. This application and result can also be a factor to contribute to the non-detection drugs management in fishery products.