• Title/Summary/Keyword: Rays

Search Result 2,317, Processing Time 0.025 seconds

ON THE MORPHOLOGY OF POST-LARVAL AND YOUNG STAGES OF OMOBRANCHUS ELEGANS(STEINDACHNER) (앞동갈베도라치 Omobranchus elegans (STEINDACHNER)의 자치어기의 형태)

  • KIM Yong Uk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.297-303
    • /
    • 1979
  • Early morphological changes of Omobranchus slogans (STEINDACHNER) (Family Blennidae) were studied based on the samples of 125 individuals collected from Changseon channel of Nam-hae in June 1973 and May 1979. Descriptions were made with particular emphasis on developmental changes of supraorbital region, fin rays, development of chromatophores and the preopercular spine. In the early stages the lateral profile of the supraorbital region is perpendicular to tile sagittal plane, however, in the later stages it becomes curved. In the early stage of 5.55 mm in total length the number of soft rays of dorsal fin is 18, and that of the anal fin 15. Ventral fin first appears as a premoidal proturberance. It fully developes into a fin composed of two soft rays in the stages of 12.9 mm in total length. The caudal fin rays first appear in the ventral part and in the stages of 6.15 mm in total length it gets one or two soft rays which bear 1-2 segments. In the later stages each ray bears more than 5 segments. Melanophores first appear as two black spots on the central part of the head. They are distributed on the opercle and the antero-dorsal surface of the trunk in the stage of 18mm in total length. At this stage the general chromatophore. pattern is identical to the adult stage. The anal fin bears melanophores at the basal part of the rays, and it is one of the remarkable morphological characters of this species. In early stages the preopercular spine develops reaching the basal part of the pectoral fin. In the later stages of 15 mm in total length relative length of the spine decreases to total length, and ie reaches only the distal margin of the opercular.

  • PDF

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.

Gamma-ray emission from millisecond pulsars - an Outergap perspective

  • Cheng, Kwong Sang
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.3
    • /
    • pp.153-158
    • /
    • 2013
  • In this review paper we explain the following gamma-ray emission features from the millisecond pulsars. (1) Why is the dipolar field of millisecond pulsars so weak but the magnetic pair creation process may still be able to control the size of the outergap? (2) A sub-GeV pulse component could occur in the vicinity of the radio pulse of millisecond pulsars. (3) Orbital modulated gamma-rays should exist in the black widow systems for large viewing angle.

Simulation for Dose-Rate Latchup by Transient Radiation Pulse in CMOS Device (CMOS 소자에서 과도방사선펄스에 의한 Dose-Rate Latchup 모의실험)

  • Lee, Hyun-Jin;Lee, Nam-Ho;Hwang, Young-Gwan
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1185-1186
    • /
    • 2008
  • A nuclear explosion emits a transient radiation pulse like gamma rays. Gamma rays have a high energy and cause unexpected effects in semiconductor devices. These effects are mainly referred to dose-rate latcup and dose-rate upset. By transient radiation pulse in CMOS devices, dose-rate latchup is simulated in this paper.

  • PDF

Anal Fin Deformity in the Longfin Trevally, Carangoides armatus (R$\ddot{u}$ppell, 1830) Collected from Nayband, Persian Gulf

  • Jawad, Laith;Sadighzadeh, Zahra;Salarpouri, Ali;Aghouzbeni, Seyed
    • Korean Journal of Ichthyology
    • /
    • v.25 no.3
    • /
    • pp.169-172
    • /
    • 2013
  • A malformation of the anal fin in longfin trevally, Carangoides armatus, is described and compared with normal specimens. The fish specimen is clearly shown anal fin deformity with missing of 3 spines and 6 rays. The remaining eleven anal fin rays are shorter than those in the normal specimen. The causative factors of this anomaly were discussed.

First record of Bathygobius hongkongensis (Perciformes: Gobiidae) from Jeju Island, Korea

  • Kwun, Hyuck Joon
    • Fisheries and Aquatic Sciences
    • /
    • v.23 no.7
    • /
    • pp.17.1-17.4
    • /
    • 2020
  • Six specimens of Bathygobius hongkongensis were collected for the first time from the eastern coast of Jeju Island, Korea, in September-November 2017. This species is characterized by a pectoral fin with free rays and the division of the first dorsalmost pectoral free ray into three branches; a lower jaw with a mental frenum; and an anterior nostril with a tiny flap. Bathygobius hongkongensis is similar to B. fuscus but differs in having more dorsalmost free pectoral fin rays. The new Korean name proposed for B. hongkongensis is "Nam-bang-mu-nui-mang-duk."

Application Technologies of Pulsed Power with the High Voltage and Current (고전압.대전류 pulsed power의 이용기술)

  • Lee, Hyeong-Ho;Kim, Young-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1678-1680
    • /
    • 1997
  • The pulsed power with the high voltage and current can be used to the fields of high speed pulses of energy in different forms such as electric current and voltage, electron beam, ion beam, x-rays, gamma rays, heat, magnetics fields, sound and shock waves. This paper is directed mainly at electrical engineers working on production and practical application of high speed pulsed power with high voltage and current.

  • PDF

Fermi Large Area Telescope Observations of the Dark Accelerator HESS J1745-303

  • Yeung, Paul
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.319-321
    • /
    • 2016
  • Reviewing the two MeV-GeV investigations in the field of the HESS J1745-303 performed using Fermi Large Area Telescope data, we confirmed that the emission peak comfortably coincides with 'Region A' in the TeV regime, which is the brightest part of this feature. The MeV-TeV spectrum can be precisely described by a single power-law. Also, recent investigation has shown that the MeV-GeV feature is elongated from 'Region A' toward the north-west, which is similar to the case of largescale atomic/molecular gas distribution.

Morphological Changes of Mouse Ovary by X-Ray Irradiation (방사선 조사선량에 따른 생쥐 난소의 형태학적 변화)

  • Yoon, Chul-Ho;Choi, Jong-Woon;Yoon, Surk-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.140-156
    • /
    • 2007
  • This research was performed to investigate the morphological changes of folliculus ovary according to the radiation dose. The whole body radiation of 200 cGy, 400 cGy, and 600 cGy was given to the each groups of 5 months-aged female mouse. Various staining methods used in this research are: Hematosylin-Eosin method, and immunohistochemistrical methods using BrdU, TUNEL, p53, p21, PCNA and inhibin. The minute structural changes of folliculus ovary were observed through an electron microscope with high magnification. The morphological changes of growing folliculus ovary became distinct as the dose of X-rays increased. Especially, the nuclei of granular cells showed manifest condensation and the changes of the transparent zone were distinct. As a result of histochemical reaction according to Masson's trichrome method and reticular fiber method, the changed granular cells, the deformed basilar membrane of folliculus ovary and the abnormal arrangement of the reticular fiber were observed. In the reaction of BrdU, the granular cells of normal folliculus ovary with positive reaction rapidly decreased according to the increase of the dose of X-rays. In TUNEL study, granular cells showing positive reaction in retarded folliculus ovary were expanded to growing folliculus ovary and primordial folliculus ovary according to the increase of the dose of X-rays. In case of 600 cGy of X-rays, oocyte underwent apoptosis. In p53 immunohistochemistry, p53 manifested to be stronger as the dose of X-rays increased. p53 reactivity was manifested distinctively in all cells comprising folliculus ovary following irradiation of 600 cGy. p21 was manifested in granular cells of folliculus ovary and showed very positive reaction around follicular antrum according to the increase of the dose of X-rays. In PCNA, positive reaction was manifested in growing folliculus ovary, mature folliculus ovary and primordial folliculus ovary, but the extent of the reaction decreased as the dose of the X-rays decreased. The finding that the reaction of granular cells around folliculus ovary was stronger than that near follicular membrane indicates that what was damaged first by X-ray was the cells near folliculus ovary and follicular antrum. The reactivity of $inhibin-{\alpha}$ showed difference according to the growing stage of folliculus ovary: $inhibin-{\alpha}$ showed the most strong reaction in mature folliculus ovary with follicular antrum. There was strong reaction in granular cells around follicular membrane but $inhibin-{\alpha}$ did not occur at all in theca cells comprising follicular membrane. $Inhibin-{\alpha}$ in ovary tissue exposed to 400 cGy of X-rays was manifested more strongly than in ovary tissue exposed to 600 cGy of X-rays, which was related to the phenomenon that granular cells of mature folliculus ovary underwent necrosis or apoptosis increasingly due to X-rays. In an electron microscope with high magnification, nuclei and protoplasm of granular cells in growing folliculus ovary abruptly underwent minute structural changes according to the increase of dose of X-rays. Cell residue, by-product of cell decease, neutrophil and macrophage around follicular antrum were observed. The minute structural changes in granular cells showed typical characteristics of apoptosis: the increase of electronic density due to nuclear condensation, fragmentation of nuclei and atrophy of protoplasm. Necrosis of cells was identified but it was not so remarkable. Macrophage with apoptotic bodies was scattered. Proportional to the radiation dose, we found that the generation of heterogeneous substance of normal ovary texture's follicular fluid, the emergence of dyeing characteristic in the basilar membrane of folicle, the generation of apoptosis, and the transformation of macrophages, etc. From this results, we can infer the possible radiation hazard on the ovary of cervix cancer patient with radiation therapy.