• Title/Summary/Keyword: Rays

Search Result 2,309, Processing Time 0.027 seconds

Radiation Protection Effect of Mixed Extracts of Hottuynia, Perilla Frutescens, Camellia Sinnensis in the SD Rat (SD Rat에서 어성초, 자소엽, 녹차 혼합 추출물의 방사선 방호 효과 연구)

  • Jae-Hyeong Park;Geun-Woo Jeong;Seong-Ock Jin;Jae-Gyeong Choi;Sung-Hyun Joo;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.161-169
    • /
    • 2024
  • This study confirmed the radioprotective effects of a mixed extracts of Hottuynia, Perilla Frutescens, and Camellia Sinnensis as natural radioprotectors on the prostate, small intestine, and liver of SD rats. It is known that Hottuynia, Perilla Frutescens, and Camellia Sinnensis have antioxidant effects on the prostate, small intestine, and liver, respectively.In this study, SD rats were irradiated with 8 Gy of gamma rays to confirm the radioprotective effects of a mixed extracts of Hottuynia, Perilla Frutescens, and Camellia Sinnensis. After radiation irradiation, histological analysis of the prostate, small intestine, and liver was performed. After radiation irradiation, histological analysis of the prostate, small intestine, and liver was performed. In the case of the prostate, the HPC+IR Group had less prostate damage and better recovery due to radiation compared to the IR Group. It was confirmed that the prostate size of the HPC+IR Group was 11.48%p and 24.54%p higher than the IR Group on 1st and 7th days. In the case of the small intestine, the HPC+IR Group had less radiation-induced small intestinal damage and recovery was better than the IR Group. The length of small intestine villus in the HPC+IR Group was confirmed to be 23.73%p and 24.27%p higher than the IR Group on the 1st and 7th days. In the case of the liver, the HPC+IR Group had less liver damage due to radiation and had better recovery than the IR Group. This was confirmed through the hepatic portal vein and surrounding cells. The results of this study are considered to be used as basic data for research on natural radiation protection using mixed extracts.

Retrospective Analysis of Clinical Patterns and Antibiotic Utilization in Pediatric Patients Hospitalized with Respiratory Syncytial Virus Pneumonia at a Recently Established General Hospital (신생 대학병원에서 호흡기세포융합바이러스 폐렴으로 입원한 건강한 소아청소년환자에서의 임상 양상 및 항생제 사용에 대한 후향적 분석)

  • Hyejin So;Kyung Min Kim;Eun Young Cho
    • Pediatric Infection and Vaccine
    • /
    • v.31 no.1
    • /
    • pp.75-82
    • /
    • 2024
  • Purpose: As the coronavirus disease 2019 (COVID-19) pandemic ended, the number of patients with respiratory syncytial virus (RSV) pneumonia increased during the spring/summer of 2022. This study aimed to analyze the clinical features and antibiotic usage of children hospitalized for RSV pneumonia in a recently established general hospital in Sejong city. Methods: In this retrospective review, we included inpatients of the Pediatric Department of Chungnam National University Sejong Hospital diagnosed with RSV pneumonia between March 2022 and April 2023. Patients were divided into 2 groups: with and without antibiotic treatment. Demographic data, initial presentations, and clinical courses were reviewed. Results: A total of 116 patients with RSV pneumonia were hospitalized during this period, of which 102 were analyzed, excluding 14 with underlying diseases or who did not fall within the definition of pneumonia. The median age was 17 months. Diagnoses of bacterial infections (acute otitis media and sinusitis) were documented in 9.8% of cases. Intravenous (IV) antibiotics were administered in 46% of cases. The group receiving IV antibiotics showed higher inflammatory levels (C-reactive protein; CRP), more infiltration on initial chest X-rays, and longer fever duration. There was no difference in the length of hospitalization between the groups with and without IV antibiotics. Conclusions: This study showed a tendency for the attending physician to prescribe IV antibiotics to patients with longer fever duration, pulmonary infiltrations on the initial chest X-ray, and higher CRP levels. However, given the high rate of IV antibiotic usage compared to previous studies, care should be taken in antibiotic use.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Study of Animation 3-Dimensional Motion Picture (애니메이션 입체 영화에 대한 연구)

  • Min, Kyung-Mi
    • Cartoon and Animation Studies
    • /
    • s.9
    • /
    • pp.127-142
    • /
    • 2005
  • Not only in Korea but throughout the entire world millions of people are in contact with images. Images have become a medium through which to transmit anything from simple visualizations of moving images to knowledge and information. The age of the internet has arisen thanks to scientific development, and the internet generation's acquisition of information is continuously becoming faster. The spectators, ufo must choose amongst the excessive amount of available information, are changing along with it just as quickly. The method of visual transmission has changed to match the demands of the fast-changing pace of the new generation. In order to receive an instantaneous selection amongst much information, the primary requisite is attracting one's attention, and then presenting a corresponding feeling of satisfaction. The early stages of film arose from the desire to capture one's actual situation as it realty is. Unsatisfied with the still picture, people developed the motion picture. Research has succeeded in reproducing 3-dimensional images more realistic than the actual image we perceive as a result of the difference in visual perspective of both eyes and their response to rays of light From color film to 3-dimensional pictures, people enjoy the magnificent results of this. All fields within the category of film are continuously studying the human desire to pursue their visual side, namely the pursuit of visual images with a maximum sense of reality. The images that millions of people around the world see now are flat. The screen's depth and optical illusions effectively give a sense of reality while conveying information. However, although the flat screen is able to create a sense of depth using the different visual perspective of each eye for the realization of a cubic effect, there are limitations. Entering the 21s1 century, there is a quickly-arising branch within the field of image media which seeks to overcome these limitations Although 3-dimensional images began in films, entering the latter half of the 20th century, due to development of 3-dimensional images using the mediums of the animation field, cellular phones, advertisement screens, television etc., without restriction is designated as 'image.'. With research having started around 1900 and continuing for over 100 years, we are now able to witness the popularization of 3-dimensional films happening before our very eyes. Within our own country, we can frequently see them at amusement parks and museums. In the future, through the popularization of HDTV etc., there is a good outlook for practical use of 3-dimensional images in televisions with advanced picture qualify as well as in other areas. Together with the international current, research on 3-dimensional films has been activated in Korea and is rising as a main current in the film industry. Within this context, the contents and understanding of 3-dimensional images must keep in step with the pace of technical advancements. In order to accelerate of development of film contents to keep in pace with technical developments, this dissertation presents the techniques and technical aspects of future developments, and shows the need to prepare in advance to make the field grow- and thereby avoid having a lack of experts and being conquered by other nations in the field - rather than only advancing the technical aspects and importing the contents. This dissertation aims to stimulate interest and continual research by progressive-thinking people related to the film industry. Part II looks into the definition and types of 3-dimensional motion pictures, the terminology, the fundamentals of image formation, current market fluctuations, and looks into 3-dimensional techniques which can be borrowed and introduced in 3-dimensional animations. Part III concerns 3-dimensional animated films. It analyzes 3-dimensional production techniques while using the introduction of specific animation techniques in the 2004 production Lee Sun Shin and Nelson - Naval Heroes 3-dimensional animation produced in 2004 by Clay & Puppet Stop-Motion Animation & Computer Graphic. Original Korean title: 해전영웅 이순신과 넬슨. as an example, and it also looks into how current film techniques used in animations can be applied in 3-dimensional films. Additionally, the actual stages of the various fields of 3-dimensional animations are presented. Given the current direction and advancement of 3-dimensional films making use of animations and the possible realization of this field, the author plans to weigh the development of this yet unexploited new market Not looking at the current progress of the field, but rather the direction of the hypothetical types of animation techniques, the author predicts the marketability and possibility of development of each area.

  • PDF

Individualized Determination of Lower Margin in Pelvic Radiation Field after Low Anterior Resection for Rectal Cancer Resulted in Equivalent Local Control and Radiation Volume Reduction Compared with Traditional Method (하전방 절제술을 시행한 직장암 환자에서 방사선조사 영역 하연의 개별화)

  • Park Suk Won;Ahn Yong Chan;Huh Seung Jae;Chun Ho Kyung;Kang Won Ki;Kim Dae Yong;Lim Do Hoon;Noh Young Ju;Lee Jung Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.194-199
    • /
    • 2000
  • Purpose : Then determining the lower margin of post-operative pelvic radiation therapy field according to the traditional method (recommended by Gunderson), the organs located in the low pelvic cavity and the perineum are vulnerable to unnecessary radiation. This study evaluated the effect of individualized determination of the lower margin at 2 cm to 3 cm below the anastomotic site on the failure patterns. Materials and Methods . Authors included ぉ patients with modified Astler-Coiler (MAC) stages from B2 through C3, who received low anterior resection and post-operative pelvic radiation therapy from Sept. 1994 to May 1998 at Samsung Medical Center, Sungkyunkwan University. The numbers of male and female patients were 44 and 44, and the median age was 57 years (range: 32-81 years). Three field technique (posterior-anterior and bilateral portals) by 6, 10, 15 MV X-rays was used to deliver 4,500 cGy to the whole pelvis followed by Sn cGy's small field boost to the tumor bed over 5.5 weeks. Sixteen patients received radiation therapy by traditional field margin determination, and the lower margin was set either at the low margin of the obturator foramen or at 2 cm to 3 cm below the anastomotic site, whichever is lower. In 72 patients, the lower margin was set at 2 cm to 3 cm below the anastomotic site, irrespectively of the obturator foramen, by which the reduction of radiation volume was possible in 55 patients ($76\%$). Authors evaluated and compared survival, local control, and disease-free survival rates of these two groups. Results : The median follow-up period was 27 months (range : 7-58 months). MAC stages B2 in 32($36\%$), B3 in 2 ($2\%$), Cl in 2 ($2\%$), C2 in 50 ($57\%$), and C3 in 2 ($2\%$) Patients, respectively. The entire patients' overall survival rates at 2 and 4 years were $94\%$ and $68\%$, respectively, and disease-free survival rates at 2 and 4 years were $86\%$ and $58\%$, respectively. The first failure sites were local only in 4, distant only in 14, and combined local and distant in 1 patient, respectively. There was no significant difference with respect to local control and disease-free survival rates ( p=0.42, p=0.68) between two groups of different lower margin determination policies. Conclusion : The new concept in the individualized determination of the lower margin depending on the anastomotic site has led to the equivalent local control and disease-free survival rates, and is expected to contribute to the reduction of unnecessary radiation-related morbidity by reduction of radiation volume, compared with the traditional method of lower margin determination.

  • PDF

Postoperative Radiation Therapy for Chest Wall Invading pT3N0 Non-small Cell Lung Cancer: Elective Lymphatic Irradiation May Not Be Necessary (흉벽을 침범한 pT3N0 비소세포폐암 환자에서 수술 후 방사선치료)

  • Park, Young-Je;Ahn, Yong-Chan;Lim, Do-Hoon;Park, Won;Kim, Kwan-Min;Kim, Jhingook;Shim, Young-Mog;Kim, Kyoung-Ju;Lee, Jeung-Eun;Kang, Min-Kyu;Nam, Hee-Rim;Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.253-260
    • /
    • 2003
  • Purpose: No general consensus has been reached regarding the necessity of postoperative radiation therapy (PORT) and the optimal techniques of its application for patients with chest wall invasion (pT3cw) and node negative (NO) non-small cell lung cancer (NSCLC). We retrospectively analyzed the PT3cwN0 NSCLC patients who received PORT because of presumed inadequate resection margin on surgical findings. Materials and Methods: From Aug. 1994 till June 2000, 21 pT3cwN0 NSCLC patients received PORT at Samsung Medical Center; all of whom underwent curative on-bloc resection of the primary tumor plus the chest wall and regional lymph node dissection. PORT was typically stalled 3 to 4 weeks after operation using 6 or 10 MV X-rays from a linear accelerator. The radiation target volume was confined to the tumor bed plus the immediate adjacent tissue, and no regional lymphatics were included. The planned radiation dose was 54 Gy by conventional fractionation schedule. The survival rates were calculated and the failure patterns analyzed. Results: Overall survival, disease-free survival, loco-regional recurrence-free survival, and distant metastases-free survival rates at 5 years were 38.8$\%$, 45.5$\%$, 90.2$\%$, and 48.1$\%$, respectively. Eleven patients experienced treatment failure: six with distant metastases, three with intra-thoracic failures, and two with combined distant and intra-thoracic failures. Among the five patients with intra-thoracic failures, two had pleural seeding, two had in-field local failures, and only one had regional lymphatic failure in the mediastinum. No patients suffered from acute and late radiation side effects of RTOG grade 3 or higher. Conclusion: The strategy of adding PORT to surgery to improve the probability, not only of local control but also of survival, was justified, considering that local control was the most important component in the successful treatment of pT3cw NSCLC patients, especially when the resection margin was not adequate. The incidence and the severity of the acute and late side effects of PORT were markedly reduced, which contributed to improving the patients' qualify of life both during and after PORT, without increasing the risk of regional failures by eliminating the regional lymphatics from the radiation target volume.

The Developmental Effects of Radiation on ICR Mouse Embryos in Preimplantation Stage (착상전기(着床前期)에 있어서 ICR Mouse의 태아(胎兒)에 대한 방사선(放射線) 개체(個體) Level 영향(影響)의 연구(硏究))

  • Gu, Yeun-Hwa
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.273-284
    • /
    • 1996
  • Embryos and fetuses are more sensitive to various environmental agents than are adults or children. The biological effects such as intrauterine death and malformation are closely connected with prenatal exposure very various agents. The sensitivity of these embryonic/fetal effects depends on the stage of pregnancy. From the viewpoint of fetal development, embryonic and fetal stages can be divided into three stages : Preimplantation, organogenetic and fetal. Each stage corresponds to 0 to 4.5days, 4.5 to 13.5days, and 13.5days of gestation in mice, respectively. Many studies on the biologcal effects of mice irradiated by ${\gamma}-rays$ at various stages during organogenesis and fetal period have been performed. Based on these results, the dose-effect and dose-response relationships in malformations, intrauterine death, or retardation of the physical growth have been practically modeled by the ICRP(International Commission on Radiological Protection) and other international bodies for radiation protection. Many experimental studies on mice have made it clear that mice embryos in the preimplantation period have a higher sensitivity to radiation for lethal effects than the embryos/fetuses on other prenatal periods. However, no eratogenic effects of radiation at preimplantation stages of mice have been described in many textbooks. It has been believed that 'all or none action results' for radiation of mice during the preimplantation period were applied. The teratogenic and lethal effects during the preimplantation stage are one of the most important problems from the viewpoint of radiological protection, since the preimplantation stage is the period when the pregnancy itself is not noticed by a pregnant woman. There are many physical or chemical agents which affect embryos/fetuses in the environment. It is assumed that each agents indirectly effects a human. Then, a safety criterion on each agent is determined independently. The pregnant ICR mice on 2, 48, 72 or 96 hours post-conception (hpc), at which are preimplantation stage of embryos, were irradiated whole body Cesium-gamma radiation at doses of 0.1, 0.25, 0.5, 1.5, and 2.5 Gy with dose rate of 0.2 Gy/min. In the embryos from the fetuses from the mice irradiated at various period in preimplantation, embryonic/fetal mortalities, incidence of external gross malformation, fetal body weight and sex ratio were observed at day 18 of gestation. The sensitivity of embryonic mortalities in the mice irradiated at the stage of preimplantation were higher than those in the mice irradiated at the stage of organogenesis. And the more sensitive periods of preimplantation stage for embryonic death were 2 and 48 hpc, at which embryos were one cell and 4 to 7 cell stage, respectively. Many types of the external gross malformations such as exencephaly, cleft palate and anophthalmia were observed in the fetuses from the mice irradiated at 2, 72 and 96 hpc. However, no malformations were observed in the mice irradiated at 48 hpc, at which stage the embryos were about 6 cell stage precompacted embryos. So far, it is believed that the embryos on preimplantation stage are not susceptible to teratogens such as radiation and chemical agents. In this study, the sensitivity for external malformations in the fetuses from the mice irradiated at preimplantation were higher than those in the fetuses on stage of organogenesis.

  • PDF

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF