• Title/Summary/Keyword: Ray-sum

Search Result 56, Processing Time 0.033 seconds

Structural Analysis of 2-Benzyl-3-[3-(4-bromo-phenyl)-1-phenyl-1H-pyrazol-4yl]-4,6-dioxo-5-phenyl-octahydro-pyrrolo[3,4-C]pyrrole-1-carboxylic Acid Ethyl Ester through X-ray Crystallography

  • Ganapathy, Jagadeesan;Pramesh, M.;Perumal, P.T.;Sanmargam, Aravindhan
    • Journal of Integrative Natural Science
    • /
    • v.8 no.3
    • /
    • pp.192-203
    • /
    • 2015
  • In view of the growing medicinal importance of pyrazole and its derivatives, the single crystal X-ray diffraction study was carried out for the potential active 2-Benzyl-3-[3-(4-bromo-phenyl)-1-phenyl-1H-pyrazol-4yl]-4,6-dioxo-5-phenyl-octahydro-pyrrolo[3,4-C]pyrrole-1-carboxylic acid ethyl ester ($C_{37}H_{31}BrN_4O_4$, H2O). In the title compound are two molecules exist in the asymmetric unit. It crystallizes in the monoclinic space group $P{\hat{i}}$ with unit cell dimension $a=13.361(18){\AA}$, $b=13.424(17){\AA}$ and $c=21.649(2){\AA}$ [${\alpha}=80.745(9)^{\circ}$, ${\beta}=79.770(10)^{\circ}$ and ${\gamma}=60.788(6)^{\circ}$]. The pyrazole ring adopts planar conformation. The sum of the bond angles at nitrogen atom of the pyrazole ring indicates the $Sp^2$ hybridized state. The crystal structure is stabilized by intramolecular C-H...O hydrogen bond interaction.

A study on the visible wave of transmittance pressable ceramic core (열가압성형도재 코어의 가시광선 투과율에 관한 연구)

  • Jung, In-Ho;Lee, Sang-Deok;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the transmittance differences of pressable ceramic core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 2 groups (0.6mm, 0.8mm) which have each 3 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown. Also, When making all ceramic core with dead pulp (nervous treatment tooth) when used as a restorative esthetic think is more efficient to improve.

A study on the transmittance due to thickness of zirconium core (지르코니아 코어의 두께에 따른 분광광도계 투과율에 관한 연구)

  • Jung, In-Ho;Park, Myung-Ja;Kim, Joo-Won
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.129-136
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the transmittance differences of zirconium core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 3 groups (0.6mm, 0.8mm, 1.0mm) which have each 12 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown.

SCATTERING CORRECTION FOR IMAGE RECONSTRUCTION IN FLASH RADIOGRAPHY

  • Cao, Liangzhi;Wang, Mengqi;Wu, Hongchun;Liu, Zhouyu;Cheng, Yuxiong;Zhang, Hongbo
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.529-538
    • /
    • 2013
  • Scattered photons cause blurring and distortions in flash radiography, reducing the accuracy of image reconstruction significantly. The effect of the scattered photons is taken into account and an iterative deduction of the scattered photons is proposed to amend the scattering effect for image restoration. In order to deduct the scattering contribution, the flux of scattered photons is estimated as the sum of two components. The single scattered component is calculated accurately together with the uncollided flux along the characteristic ray, while the multiple scattered component is evaluated using correction coefficients pre-obtained from Monte Carlo simulations.The arbitrary geometry pretreatment and ray tracing are carried out based on the customization of AutoCAD. With the above model, an Iterative Procedure for image restORation code, IPOR, is developed. Numerical results demonstrate that the IPOR code is much more accurate than the direct reconstruction solution without scattering correction and it has a very high computational efficiency.

XMCD and PES study of a compensated-ferrimagnetic half-metal Mn3Ga

  • Seong, Seungho;Lee, Eunsook;Kim, Hee Yeon;Kim, Younghak;Baik, Jaeyoon;Kang, J.S.
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1190-1195
    • /
    • 2018
  • By employing soft X-ray magnetic circular dichroism (XMCD), soft X-ray absorption spectroscopy (XAS), and photoemission spectroscopy (PES), we have investigated the electronic structure of the candidate zero-moment half-metallic $Mn_3Ga$. We have studied the ball-milled and annealed $Mn_3Ga$ powder samples that exhibit nearly zero magnetization. Mn 2p XAS revealed that Mn ions in $Mn_3Ga$ are nearly divalent for both of the Mn ions having the locally octahedral symmetry and those having the locally tetrahedral symmetry. The measured Mn 2p XMCD spectrum of $Mn_3Ga$ is very similar to that of ferrimagnetic $MnFe_2O_4$ having divalent Mn ions. The sum-rule analysis of the Mn 2p XMCD spectrum shows that both the spin and orbital magnetic moments of Mn ions in $Mn_3Ga$ are negligibly small, in agreement with the nearly compensated-ferrimagnetic ground state of $Mn_3Ga$. The valence-band PES spectrum of $Mn_3Ga$ agrees well with the calculated density of states, supporting the half-metallic electronic structure of $Mn_3Ga$.

Allanite Mineralization in the Mt. Eorae Area (어래산지역(御來山地域)의 갈렴석광상(褐簾石鑛床))

  • Oh, Mihn-Soo
    • Economic and Environmental Geology
    • /
    • v.22 no.2
    • /
    • pp.151-166
    • /
    • 1989
  • A study of rare-earth mineralization in Kyemyungsan metasedimentary formation of Precambrian Ogcheon Group was carried out in the Mt. Eore Area near Choongju City based on the thorium (Th) and uranium (U) count data of geophysical airborne survey. This rare-earth mineralization was found in the magnetite-bearing banded quartizite which contains diagnostically some amounts of the metamict allanite. The brown colored allanites are distributed as aggregates of fine grains and sometimes banded structures with magnetite (inter growth) along the banding. The ore bed is displaced by the small faults and granite intrusions, and separated 5 ore blocks. The dimensions of the outcrop are 50-80 m in width, 1,500 m in length with the strike of $N70-80^{\circ}E$ and dip of $50-80^{\circ}NW$. In the field, the values of total gamma ray count of GR-101A scintillometer were able to measure more than 400 cps and maximum 1,500 cps, which data are coincided with the values of GR-310 gamma ray spectrometer and the gamma ray count of well logging data. The chemical compositions of the allanites from EPMA data are ranged from$\sum^{TR_2O_3}$ 18.57% to 26.00%, and the cerium oxides ($Ce_2O_3$) of allanite are positive relation with $La_2O_3$, MgO, FeO, MnO and negative relation with $SiO_2$, $Al_2O_3$, $Nd_2O_3$. The result of Neutron Activation Analysis (N.A.A.), Multi-Channel Analysis (M.C.A.) and wet chemistry of 25 outcrop samples for the elements of REE, Zr, U, Th shows strong anomalies. The good correlation elements with the thorium (Th) are the elements of La, Ce, LREE, $TR_2O_3$, Pr, Sm, Yb, Lu by the increasing order.

  • PDF

Application of X-ray Computer Tomography (CT) in Cattle Production

  • Hollo, G.;Szucs, E.;Tozser, J.;Hollo, I.;Repa, I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.12
    • /
    • pp.1901-1908
    • /
    • 2007
  • The aim of this series of experiments was to examine the opportunity for application of X-ray computer tomography (CT) in cattle production. Firstly, tissue composition of M. longissimus dorsi (LD) cuts between the $11-13^{th}$ ribs (in Exp 1. between the $9-11^{th}$ ribs), was determined by CT and correlated with tissue composition of intact half carcasses prior to dissection and tissue separation. Altogether, 207 animals of different breeds and genders were used in the study. In Exp. 2 and 3, samples were taken from LD cuts, dissected and chemical composition of muscle homogenates was analysed by conventional procedures. Correlation coefficients were calculated among slaughter records, tissues in whole carcasses and tissue composition of rib samples. Results indicated that tissue composition of rib samples determined by CT closely correlated with tissue composition results by dissection of whole carcasses. The findings revealed that figures obtained by CT correlate well with the dissection results of entire carcasses (meat, bone, fat). Close three-way coefficients of correlation (r = 0.80-0.97) were calculated among rib eye area, volume of cut, pixel-sum of adipose tissue determined by CT and intramuscular fat or adipose tissue in entire carcasses. Estimation of tissue composition of carcasses using equations including only CT-data as independent variables proved to be less reliable in prediction of lean meat and bone in carcass ($R^2 = 0.51-0.86$) than for fat (($R^2 = 0.83-0.89$). However, when cold half carcass weight was also included in the equation, the coefficient of determination exceeded $R^2 = 0.90$. In Exp. 3 tissue composition of rib samples by CT were compared to the results of EUROP carcass classification. Findings revealed that CT analysis has higher predictive value in estimation of actual tissue composition of cattle carcasses than EUROP carcass classification.

The Crystal Structure of Nicotine Dihydroiodide (Nicotine Dihydroiodide의 結晶構造)

  • Koo, Chung-Hoe;Kim, Hoon-Sup
    • Journal of the Korean Chemical Society
    • /
    • v.9 no.3
    • /
    • pp.134-141
    • /
    • 1965
  • Crystals of nicotine dihydroiodide, are orthorhombic with space group $p2_12_12_1$.The unit cell of dimensions a=7.61, b=11.01, e=17.27${\AA}$, contains four formula units. The structure has been determined by X-ray diffraction method and has been refined to give the R-index, ${\sum}{\mid}{\mid}F_{\circ}{\mid}-{\mid}F_c{\mid}{\mid}{\div}{\sum}{\mid}F_{\circ}{\mid}$, of 0.16 and 0.14 for $F_{okl}\;and\;F_{hol}$ respectively.The mean lengths of C-C and C-N bonds in pyridine ring are 1.40 and $1.35{\AA}$ and those in pyrolidine ring 1.56 and $1.48{\AA}$ respectively, though accurate measurement of bond length has not been attempted. The six atoms in the pyridine ring are coplanar and on the other hand $C_6,\;C_7,\;C_8$ and $N_2$ atoms in pyrrolidine ring form a plane within accuracy of the analysis, and $C_9$ atom is distant $0.22{\AA}$ out of the plane consist of $C_6,\;C_7,\;C_8$ and $N_2$ aoms. The normals to the two planes form an angle of $94^{\circ}$ with each other. Iodine atom is distant $3.55{\AA}$ from nitrogen atom in pyridine ring and the other iodine atom $3.58{\AA}$ from nitrogen atom in pyrrolidine ring, so that the nitrogen and iodine atoms are firmly linked.It seems that the only forces binding nicotine dihydroiodide molecules together in the crystal are Van der Waals forces.

  • PDF

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

Voltage Stability Enhancement by Optimal Placement of UPFC

  • Kowsalya, M.;Ray, K.K.;Shipurkar, Udai;Saranathan
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.310-314
    • /
    • 2009
  • This paper presents the improvement of the voltage profiles of power system networks by the inclusion of Unified Power Flow Controller (UPFC). The mathematical model of the UPFC is incorporated in the load flow algorithm and the L-index is calculated for the different values of the control parameter r $and{\gamma}$. The positioning of the UPFC device is changed to minimize the sum of the squares of the L-indices at all load buses. The test cases considered for the improvement of voltage profile with the WSCC 9-bus and IEEE 30 bus system. With the best position of UPFC along with the control parameters the improvement in voltage profile of the power system networks are obtained. The results obtained are quite encouraging compared with other techniques used to identify the best location of UPFC.