• 제목/요약/키워드: Ray Density

검색결과 1,743건 처리시간 0.035초

The Propagation of Cosmic Ray in Protoplanetary Disks

  • Roh, Soonyoung;Fujii, Yuri I.;Inutsuka, Shu-ichiro;Suzuki, Takeru;Momose, Munetake
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.72.4-73
    • /
    • 2016
  • For the development of magneto rotational instability, which drives mass accretion in protoplanetary disks, sufficient ionization degree is needed. Cosmic rays are believed to be one of the dominant ionization sources for protoplanetary disk gas. In previous studies, ionization rates are computed by considering the effect of attenuation of the cosmic ray (CR) intensity as a function of column density in an unmagnetized cloud. However, in reality particles should sweep up larger column density to reach at the midplane of disk due to their gyromotion. In this study, we investigate the propagation of CR protons in a protoplanetary disk by solving transport and energy loss equations. We discuss the change in CR intensity due to magnetic field in a protoplanetary disk.

  • PDF

DMF 처리한 초극세 PET 섬유의 물성 및 염색성 (Physical and Dyeing Properties of PET Ultramicrofiber Treated with DMF)

  • 정동석;이문철
    • 한국염색가공학회지
    • /
    • 제14권5호
    • /
    • pp.277-283
    • /
    • 2002
  • Poly(ethylene terephthalate)(PET) filaments of regular(monodenier 2.08d) and ultramicrofiber (monodenier 0.05d) were treated with dimethylformamide(DMF) to observe the structure change of the PET such as shrinkage, density, X-ray diffraction of the UMF treated with DMF were measured. Also, dyeing experiments were performed to see the effects of DMF. The dyeability was improved by DMF treatments, and the equilibrium dye uptake increased in spite of the increase in the density and birefringence and crystallinity. The heat shrinkage appeared in PET UMF treated PET UMF treated with DMF at $80^\circ{C}$ by TMA, DSC, and Reovibron analysis and $T_m$ peak was shown by DSC analysis.

종격동 지방종 및 지방육종: 3례 보고 (Mediastinal lipoma and liposarcoma)

  • 김원곤;김주현
    • Journal of Chest Surgery
    • /
    • 제16권3호
    • /
    • pp.375-380
    • /
    • 1983
  • The lipomatous of the mediastinum are fairly uncommon tumors. Since 1971, two patients with proven mediastinal lipoma and one primary liposarcoma of the mediastinum have been treated at the Seoul National University Hospital. This report reviews our experience with the review of literature. Case 1.: A 3 year old body revealed a huge round homogenous mass density in the posterior mediastinum in routine chest X-ray. The tumor mass, lipoma, was successfully removed and postoperative course was uneventful. Cases 2.: An asymptomatic 24 year old male was operated on with the preoperative diagnosis of mediastinal lipoma. His preoperative chest X-ray and CT films showed a huge anterior to middle mediastinal tumor, right, with fat density. There is no postoperative problem after successful removal of the tumor mass. Case 3. : A 24 year old female was hospitalized with the complaints of cough and chest pain. A mediastinal mass was removed, which proved to be a liposarcoma on pathologic examination. About one year later, she was found to have recurrent liposarcoma in the right chest area at the OPD follow-up. She was lost to follow-up since then.

  • PDF

Impacts of halloysite clay nanoparticles on the structural and γ-ray shielding properties of the epoxy resin

  • K.G. Mahmoud;M.I. Sayyed;S. Hashim;Aljawhara H. Almuqrin;Abu El-Soad A.M
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1585-1590
    • /
    • 2023
  • In this study, halloysite nanoparticles-doped epoxy resin was synthesised using the casting method. The MH-300A density metre revealed that the density of the fabricated composites changed from 1.132 to 1.317 g/cm3 as the halloysite nanoparticle concentration increased. The Fourier transform infrared was recorded for the synthesised composites. Furthermore, the γ-ray shielding properties of the synthesised composites were evaluated using Monte Carlo simulation and a theoretical programme, XCOM. The linear attenuation coefficient of the epoxy resin increased by 43% (at γ-energy of 15 keV) and 14% (at γ-photon energy of 662 keV) when the concentration of the halloysite nanoparticles was increased from 0 wt% to 40 wt%, respectively.

Modeling of Ultrasonic Testing in Butt Joint by Ray Tracing

  • Nam, Young-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제15권4호
    • /
    • pp.441-447
    • /
    • 2001
  • Ultrasonic wave generation and propagation were modeled to simulate an ultrasonic test. A ray model was used for the modeling. Actual sound pressure distribution of the incident wave from an angle probe was analyzed using an ultrasonic visualization method to incorporate the actual sound pressure distribution in the model. In this method, the sound pressure was expressed by the density of rays and the reflection coefficient of ultrasonic beams. Reflection and mode conversion of rays were computed by the Snells law. Simulation programs for the problem of ultrasonic testing of a butt joint are built using this ray modeling. Simulation results for ultrasonic wave scattering from a defect and A-scan display in ultrasonic testing agreed with the actual experiment results.

  • PDF

COLOR DISTRIBUTIONS OF 29 GALACTIC GLOBULAR CLUSTERS

  • Sohn, Young-Jong;Byun, Yong-Ik;Yim, Hong-Suh;Rhee, Myung-Hyun;Chun, Mun-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • 제15권1호
    • /
    • pp.1-26
    • /
    • 1998
  • The structure of the magnetic funnel element in the intermediate polar is con-sidered in terms of an important site for the X-ray absorption and the reemis-sion of the X-ray as the optical light. In this paper the column density and the optiacl depth vary with the filling factor, which is introduced to characterize the structure of matter in the magnetic funnel element. The results of the en-ergy dopendence of the X-ray spectrum and the modulation depth of the X-ray light curve are discussed.

  • PDF

Development of hand-held coded-aperture gamma ray imaging system based on GAGG(Ce) scintillator coupled with SiPM array

  • Jeong, Manhee;Hammig, Mark
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2572-2580
    • /
    • 2020
  • Emerging gamma ray detection applications that utilize neutron-based interrogation result in the prompt emission of high-energy (>2 MeV) gamma-rays. Rapid imaging is enabled by scintillators that possess high density, high atomic number, and excellent energy resolution. In this paper, we evaluate the bright (50,000 photons/MeV) oxide scintillator, cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)). A silicon photomultiplier (SiPM) array is coupled to a GAGG(Ce) scintillator array (12 × 12 pixels) and integrated into a coded-aperture based gamma-ray imaging system. A resistor-based symmetric charge division circuit was used reduce the multiplicity of the analog outputs from 144 to 4. The developed system exhibits 9.1%, 8.3%, and 8.0% FWHM energy resolutions at 511 keV, 662 keV, and 1173.2 keV, respectively. In addition, a pixel-identification resolution of 602 ㎛ FWHM was obtained from the GAGG(Ce) scintillator array.

디지털 X선 영상센서 적용을 위한 진공증착 CsI 특성평가 (The X-ray Detection Characteristic of vacuum evaporated CsI for Digital X-ray Image Sensor)

  • 신정욱;박지군;최장용;석대우;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.15-18
    • /
    • 2003
  • In recent years, there has been keen interest in phosphor materials responding X-ray. Cesium iodide of the materials is a material with a high $\gamma$-ray stopping power due to its relative high density and atomic number. CsI is noted for its high resistance to thermal and mechanical shock due to the absence of a cleavage plane. To design the structure of CsI detector, we analysed the structure with SEM and XRD and measured UV meter.

  • PDF

골밀도 측정을 위한 Digital X-Ray 영상 처리 방법 (Digital X-Ray Image Processing Method for Bone Mineral Density Measurement)

  • 한기서;염진수;류광렬;허창우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.239-242
    • /
    • 2006
  • 골다공증은 해면골의 골소주 두께 감소 및 파단에 기인한 전체적인 골질이 저하되는 질병이다. 골다공증을 예방과 조기진단을 하기 위해서는 골밀도를 측정하여야 한다. 보다 나은 이미지를 얻기 위해 Digital X-Ray로 골밀도를 측정하여 영상 처리하기 위한 방법을 제시한다. 먼저 디지털 센서에서 증감지와 렌즈간 거리가 가까워서 증감지의 중심과 주변부의 광 경로차이가 발생하므로 왜곡이 발생하는데 이를 균일화하여야 한다. 그리고 X-Ray장비의 조건에 따라 영상에 많은 차이를 보이므로 영상의 밝기를 보정하는 과정이 필수적이다.

  • PDF

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.