• Title/Summary/Keyword: Rating power

Search Result 516, Processing Time 0.021 seconds

Modified Kolmogorov-Smirnov Statistic for Credit Evaluation (신용평가를 위한 Kolmogorov-Smirnov 수정통계량)

  • Hong, C.S.;Bang, G.
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.6
    • /
    • pp.1065-1075
    • /
    • 2008
  • For the model validation of credit rating models, Kolmogorov-Smirnov(K-S) statistic has been widely used as a testing method of discriminatory power from the probabilities of default for default and non-default. For the credit rating works, K-S statistics are to test two identical distribution functions which are partitioned from a distribution. In this paper under the assumption that the distribution is known, modified K-S statistic which is formulated by using known distributions is proposed and compared K-S statistic.

Development of AMR System using Hybrid Communication Network (복합 통신망을 이용한 AMR 시스템 개발)

  • Kim Younghyun;Park Byungseok;Lim Yonghoon;Hyun Duckhwa
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.718-722
    • /
    • 2004
  • 본 논문에서는 전력선 통신 및 무선 통신망을 이용하여 전력 사용량을 자동적으로 검침 및 관리할 수 있는 시스템, AMR(Automated Metering Rating)을 개발한다. 본 시스템은 원격 검침 및 수요 관리, 전력정보 제공 등 지능형 부가 서비스를 지원할 수 있는 있도록 설계하고, 이렇게 설계된 시스템은 실제 환경에 설치하여 성능 시험을 수행한다.

  • PDF

Input-Series-Output-Parallel Connected DC/DC Converter for a Photovoltaic PCS with High Efficiency under a Wide Load Range

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.9-13
    • /
    • 2010
  • This paper proposes an input-series-output-parallel connected ZVS full bridge converter with interleaved control for photovoltaic power conditioning systems (PV PCS). The input-series connection enables a fully modular power-system architecture, where low voltage and standard power modules can be connected in any combination at the input and/or at the output, to realize any given specifications. Further, the input-series connection enables the use of low-voltage MOSFETs that are optimized for a very low RDSON, thus, resulting in lower conduction losses. The system costs decrease due to the reduced current, and the volumes of the output filters due to the interleaving technique. A topology for a photovoltaic (PV) dc/dc converter that can dramatically reduce the power rating and increase the efficiency of a PV system by analyzing the PV module characteristics is proposed. The control scheme, consisting of an output voltage loop, a current loop and input voltage balancing loops, is proposed to achieve input voltage sharing and output current sharing. The total PV system is implemented for a 10-kW PV power conditioning system (PCS). This system has a dc/dc converter with a 3.6-kW power rating. It is only one-third of the total PV PCS power. A 3.6-kW prototype PV dc/dc converter is introduced to experimentally verify the proposed topology. In addition, experimental results show that the proposed topology exhibits good performance.

A Study on Utilization Ratio and Operation of Transmission Lines (송전선로의 이용률 평가 및 합리적 운영에 관한 연구)

  • Kim, Dong-Min;Bae, In-Su;Cho, Jong-Man;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.426-432
    • /
    • 2006
  • This paper describes the concepts of Static Line Rating (SLR) and Dynamic Line Rating (DLR) and the computational methods to demonstrate them. Calculation of the line capacity needs the heat balance equation which is also used for computing the reduced tension in terms of line aging. SLR is calculated with the data from the worst condition of weather throughout the year. Even now, the utilization ratio is obtained from this SLR data in Korea. DLR is the improved method compared to SLR. A process for DLR reveals not only improved line ratings but also more accurate allowed line ratings based on line aging and real time conditions of weather. In order to reflect overhead transmission line aging in DLR, this paper proposes the method that considers the amount of decreased tension since the lines have been installed. Therefore, the continuous allowed temperature for remaining life time is newly acquired. In order to forecast DLR, this paper uses weather forecast models, and applies the concept of Thermal Overload Risk Probability (TORP). Then, the new concept of Dynamic Utilization Ratio (DUR) is defined, replacing Static Utilization Ratio (SUR). For the case study, the two main transmission lines which are responsible for the north bound power flow in the Seoul metropolitan area are chosen for computing line rating and utilization ratio. And then line rating and utilization ratio are analyzed for each transmission line, so that comparison of the present and estimated utilization ratios becomes available. Finally, this paper proves the validity of predictive DUR as the objective index, with simulations of emergency state caused by system outages, overload and so on.

A New Low-Cost Active Power Filter to Suppress Neutral Current Harmonics in Three-Phase Four-Wire System (3상 4선식 배전계통에서 중성선 전류 제거를 위한 새로운 저가형 능동전력필터)

  • 장민수;최세완;김기영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.359-365
    • /
    • 2002
  • Three-phase four-wire electrical distribution systems have been widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads, the neutral conductor carries excessive harmonic currents resulting in wiring failure of the neutral conductor, overloading of the distribution transformer and a voltage drop between the neutral and the ground. This paper proposes a reduced rating active power filter to suppress neutral current harmonics in three-phase four-wire electrical distribution systems. The proposed system is simple in control and the VA rating of the inverter could be significantly reduced since only the fundamental current due to unbalanced loading flows through the inverter switch. The experimental results on a prototype validate the proposed control approach.

A Economic feasibility of Superconducting Fault Current Limiter in Korean Power System (초전도한류기의 계통도입을 위한 경제적 타당성 검토)

  • Kim Jong Yul;Lee Seong Ryul;Yoon Jae Young
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.421-423
    • /
    • 2004
  • As power system grows more complex and power demands increase, the fault current tends to gradually increase. In the near future, the fault current will exceed a circuit breaker rating for some substations, which is an especially important issue in the Seoul metropolitan area because of its highly meshed configuration. Currently, the Korean power system is regulated by changing the 154kV system configuration from a loop connection to a radial system, by splitting the bus where load balance can be achieved, and by upgrading the circuit breaker rating. A development project applying 154kV Superconducting Fault Current Limiter(SFCL) to 154kV transmission systems is proceeding with implementation slated for after 2010. In this paper, the expected price of SFCL in order to assure the economic feasibility is evaluated comparing with upgrading cost of ciui.1 breakers. The results show that the SFCL should be developed under seven times of price of circuit breaker to be competitive against upgrading circuit breakers.

  • PDF

PWM Method of Voltage Type Converters with Large Modulation Ratio (변조율이 큰 전압형 컨버터의 PWM 변조방법)

  • 이사영;오봉환;김봉희;박현준;김길동;이승학;이미영
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.287-290
    • /
    • 1998
  • This paper presents PWM method which modulates two third period only during one cycle of power converter. This method is compared with the conventionl sinusoidal modulation method applying to the power converter with large capacity necessitating low switching frequency. The presented modulation method enables to reduce power semiconductor rating, minimize switching loss, and improve the current wave form.

  • PDF

Solar Cell Simulator for GEO communication spacecraft (정지궤도 통신위성용 태양전지 전원 시뮬레이터 개발)

  • 정규범;최재동;최성봉;이상석;신동희
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.138-142
    • /
    • 1998
  • This paper has been analyzed, modeled, designed, fabricated, and tested for solar cell simulator which has solar array characteristics. The main purpose is the development of solar cell simulator to test electrical power subsystem for GEO Communication Spacecraft. The maximum power of the simulator is about 5 ㎾, which is consist of 12 independent simulator modules with 420 W power rating. The 12 simulator modules are independently controlled like as real solar array system.

  • PDF

Feasibility Study of Superconducting Fault Current Limiter Application to Korean Power System

  • Kim, Hak-Man;Kim, Jong-Yul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.103-106
    • /
    • 2003
  • The short circuit current problem is one of the operational problems that need to be solved by power system engineers in Korea. It is an important issue in the Seoul metropolitan area especially because of highly meshed configuration. Currently, it is regulated by changing 154 kV system configuration from loop connection to radial system, by splitting of the bus where load balance can be achieved, and by upgrading circuit breaker rating. A development project for 154 kV/2 KA SFCL application to 154 kV transmission system after 2010 is proceeding. In this paper, a feasibility study of superconducting fault current limiter (SFCL) is carried out in Seoul metropolitan area to find out the effects of its application and feasibility. This study shows that it can reduce fault current considerably, and as it can minimize the upgrading of circuit breaker rating, the economic potential of SFCL is evaluated positively.

A Study of Output Filter Design for Current/Voltage Source Converter in High-Power Hybrid System (전류형/전압형 컨버터를 이용한 대전력 하이브리드시스템용 출력필터 구조 연구)

  • Kim, Tae-Sik;Kwak, Sang-Shin;Kwon, Woo-Hyen
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.228-230
    • /
    • 2009
  • 본 논문에서는 전류형 인버터(CSI)와 전압형 인버터(VSI)를 조합하여 유도성 부하에 정현파 전류를 공급하는 시스템에서, LC 소자를 추가함으로써 전압형 인버터의 VA rating을 줄일 수 있는 방법을 제안하였다. 전력제어용 스위칭 소자인 SCR은 대용량인 장점이 있는 반면에 턴오프 제어가 되지 않고, 비선형 특성으로 인해 고조파가 발생한다. 이러한 단점을 개선하기 위해 전압형 인버터를 사용하여, SCR를 OFF하고 부하에 정현파 전압/전류를 제공한다. 또한, 출력단에 수동 LC 필터를 추가하여 전압원 인버터의 VA rating을 저감시키는 구조를 연구하고 이를 Psim을 이용한 시뮬레이션을 통해 검증하였다.

  • PDF