• 제목/요약/키워드: Rated Power

검색결과 755건 처리시간 0.026초

도통손실을 감소시킨 강압형 영전류-영전압 컨버터에 관한 연구 (A Study on the BUCK ZC-ZVS Converter with Reduced Conduction Losses)

  • 이요섭;이원석;이성백
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.686-691
    • /
    • 1999
  • In a switching power supply, the high frequency switching makes the passive components small, but the losses and the stresses of switches are increased by the switching frequency. Therefore, zero crossing technology using resonant is used to improve defect in high switching. In generally, zero crossing switching consists of Zero Current Switching(ZCS) and Zero Voltage Switching(ZVS). This paper proposes A Buck ZC-ZVS Converter with Reduced Conduction Losses. Comparing with a conventional Buck ZC-ZVS Converter, the proposed converter operates with the smaller rated power. This is achieved by changing the auxiliary switch position, which reduces its rating power. Simulation results using Pspice program about test circuit with rated 160W(30V, 5.3A) at 30kHz and experiment result under same condition were described in the paper.

  • PDF

차축의 중량 분포와 타이어의 공기압이 트랙터 작업의 연료 효율에 미치는 영향 (Effects of Distribution of Axle Load and Inflation Pressure of Tires on Fuel Efficiency of Tractor Operations)

  • 이진웅;김경욱;김동현;최규정
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.303-313
    • /
    • 2011
  • This study was conducted to investigate the effects of axle weight distribution and inflation pressure of tire on the fuel economy of tractors as well as operational range of tractor engine in terms of engine speed and power when a 4WD tractor of 38.2 kW rated power at 2500 rpm is used for plowing and flooded-field rotavating in paddy fields. (1) Plowing operation required an average engine power of 9.6~13.5 kW which equals 25~35% of rated PTO power. Engine speed ranged from 1,320.4 to 1,737.4 rpm, work velocity from 3.4 to 4.8 km/h, and fuel consumption from 3.2 to 4.2 L/h, respectively. (2) Flooded-field rotavating required an average engine power of 11.5~18.5 kW which equals 30~48.4% of rated PTO power. Out of this 6.2~12.2 kW was used for PTO power. Engine speed ranged from 1,557 to 2,067 rpm, work velocity from 2.5~5.4 km/h and fuel consumption from 3.2~5.5 L/h, respectively. (3) Axle weight distribution, inflation pressure of tire and moisture content of soil did not affect significantly the specific volumetric fuel consumption but affected significantly the fuel consumption per unit area of operation. Fuel savings amounted to 65% in plowing operation and 20% in flooded-field rotavating when the axle weight distribution and inflation pressure of tire were optimally adjusted. (4) Optimal adjustment of axle weight distribution and inflation pressure of tire are expected to save fuel consumption by 10~65% per unit area of operation in plowing and 10~20% in flooded-field rotavating.

횡류형 터빈을 적용한 수직축 풍력발전시스템의 성능평가를 위한 실험 연구 (An Experimental Study for the Performance Analysis of a Vertical-type Wind Power Generation System with a Cross-flow Wind Turbine)

  • 조현성;정광섭;김철호
    • 한국산학기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.1272-1278
    • /
    • 2014
  • 본 최근 성장하고 있는 해상 풍력의 실험연구에서 풍동시험이 수직형 횡류 풍력발전시스템의 성능을 조사하기 위해 실시되었다. 풍동의 시험 부분은 제한된 크기로 인해 실제 풍력 발전의 입구 안내 베인을 약 1/5로 축소시켰고, 터빈 임펠러의 지름을 모형 임펠러의 1/2로 감소시켰다. 임펠러 블레이드 갯수는 풍력 발전 시스템의 출력에 대한 또 다른 중요한 변수이기 때문에 8개와 16개로 변경하여 시험하였다. 실험 분석 결과, 모형 풍력 터빈의 출력 제동력은 정격 풍속 12m/s에서 블레이드 갯수가 8개 보다 16개일 때 82% 출력이 증가된 278와트로 측정되었고, 정격 제동력은 정격 작동 조건에서 3.9kW로 계산되었다.

유한요소법과 SUMT를 이용한 동기형 릴럭턴스 전동기의 용량에 따른 회전자 구조 최적설계 (Optimum Design Criteria Based on the Rated Watt of a Synchronous Reluctance Motor Using a Coupled FEM & SUMT)

  • 권선범;이중호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권8호
    • /
    • pp.364-369
    • /
    • 2005
  • This paper deals with an automatic optimum design based on a rated output for a synchronous reluctance motor (SynRM). The focus of this paper is the motor design relative to the output power on the basis of rotor shape of a SynRM in each rated watt. And optimization algorithm is used by means of sequential unconstrained minimization technique(SUMT). The coupled Finite Elements Analysis (FEA) & Preisach model have been used to evaluate nonlinear solutions. The proposed procedure allows to define the rotor geometric dimensions according to rated watt starting from an existing motor or a preliminary design.

프라이자흐 모델이 결합된 유한요소법을 이용한 동기형 릴럭턴스 전동기의 용량에 따른 회전자 구조 설계 (Design Standard Computation based on A Rated Watt of Synchronous Reluctance Motor Using a Coupled FEM & Preisach Model)

  • 권선범;이미정;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.893-895
    • /
    • 2004
  • This paper deals with an automatic design standard computation based on a rated watt for a synchronous reluctance motor(SynRM). The focus of this paper is the design relative to the output power on the basis of rotor shape of a SynRM in each rated watt. The copuled Finite Elements Analysis(FEA) & Preisach model have been used to evaluate nonlinear solutions. The proposed procedure allows to define the rotor gemetric dimensions according to the rotor dia and rated watt starting from an existing motor or a preliminary design.

  • PDF

SUMT를 이용한 동기형 릴럭턴스 전동기의 용량에 따른 회전자 최적설계 (Optimum design criteria based on the rated watt of a Synchronous Reluctance Motor using a coupled FEM & SUMT)

  • 권선범;박중민;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1095-1097
    • /
    • 2005
  • This paper deals with an automatic design standard computation based on a rated watt for a synchronous reluctance motor(SynRM). The focus of this paper is making the design relative to the output power on the basis of rotor shape of a SynRM in each rated watt using a coupled FEM & sequential unconstrained minimization technique(SUMT). The coupled finite elements analysis(FEA) & Preisach model have been used to evaluate nonlinear solutions. The proposed procedure allows to define the rotor geometric dimensions according to the rotor diameter and rated watt starting from an existing motor or a preliminary design.

  • PDF

부스트-플라이백 결합형 ZCS Quasi-Resonant 역률개선 컨버터 (Integrated Boost-Flyback ZCS Quasi-Resonant Power Factor Preregulator)

  • 이준영;문건우;김현수;윤명중
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.91-98
    • /
    • 1999
  • 본 논문에서는 역률개선용 단일 스위치 부스트 플라이백 결합형 ZCS quasi-resonant converter(QRC)를 제안한다. 제안된 컨버터는 입력전류를 불연속 모드로 동작시켜 역률을 개선하며 입력전류의 zero-crossing-point에서의 왜곡을 개선함으로써 고조파를 감소시켜 역률을 향상시켰으며 좋은 출력전압의 regulation 성능을 가지고 있다. 그리고 체계적인 설계를 위하여 설계식을 제안하였으며 제안된 설계식을 통하여 프로토타입 컨버터를 설계하였다. 실험결과 효율은 약 86%, 역률은 약 0.985이상을 얻었다. 따라서 본 컨버터는 스위칭 주파수가 수백 kHz이상이고 높은 regulation성능을 요구하는 낮은 전압의 소용량 컨버터에 적합하다.

  • PDF

과풍속 출력 제한형 소형 풍력 발전장치 개발 (Development of the Furling Control Type Small Wind Turbine System)

  • 최영철;김철호;이현채;서영택;한용운;송정일
    • 한국정밀공학회지
    • /
    • 제29권6호
    • /
    • pp.693-701
    • /
    • 2012
  • In this study, a small wind turbine airfoil specialized for national wind condition was designed in order to develop the furling control type HAWT. And then a flow analysis was carried out based on the blade drawing which was designed to characterize of the developed airfoil. The result of the flow analysis showed that the torque on the 3 blades was 180.23N.m. This is equivalent to an output power of 5.66kw and an output efficiency of 0.44. Then we produced and constructed a 3kW - furling control type HAWT by getting the system unit design technology such as the specialized furling control device. By operating this turbine, we could get 3kW of the rated power at a wind speed of 10.5m/s through the ability test. Cut-in wind speed was 2m/s, generator efficiency was 92% at the rated power output. Sound power level was 87.2dB(A). Also we observed that the output power was limited to 10.5m/s with furling system operation.

넓은 풍속에서의 풍력발전용 권선형 유도발전기의 정출력.고역률 운전 (Constant power. high power factor drive of DFIG for wind power generation in the wide wind speed)

  • 이우석;김광태;정순용;손제봉;배종문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.693-695
    • /
    • 2000
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFIG) has good adaptivity for that purpose. This paper deals with power and power factor control using the Grid connected DFIG in the wide speed regions, by controlling frequency and voltage fed to the rotor. Power flow of the DFIG and steady-state algebraic equations of the equivalent circuit are analyzed. For a normal operating region, in which the generator ratings were not exceeded, the rotor current was either less than or equal to the rated value. Accordingly, the optimal power factor can be selected relative to the permissible rated current at the rotor coil which controls the magnitude of the injected rotor voltage to the rotor according to a given rotor frequency.

  • PDF

Development of a Novel 30 kV Solid-state Switch for Damped Oscillating Voltage Testing System

  • Hou, Zhe;Li, Hongjie;Li, Jing;Ji, Shengchang;Huang, Chenxi
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.786-797
    • /
    • 2016
  • This paper describes the design and development of a novel semiconductor-based solid-state switch for damped oscillating voltage test system. The proposed switch is configured as two identical series-connected switch stacks, each of which comprising 10 series-connected IGBT function units. Each unit consists of one IGBT, a gate driver, and an auxiliary voltage sharing circuit. A single switch stack can block 20 kV-rated high voltage, and two stacks in series are proven applicable to 30 kV-rated high voltage. The turn-on speed of the switch is approximately 250 ns. A flyback topology-based power supply system with a front-end power factor correction is built for the drive circuit by loosely inductively coupling each unit with a ferrite core to the primary side of a power generator to obtain the advantages of galvanic isolation and compact size. After the simulation, measurement, and estimation of the parasitic effect on the gate driver, a prototype is assembled and tested under different operating regimes. Experimental results are presented to demonstrate the performance of the developed prototype.