• Title/Summary/Keyword: Rate of penetration

Search Result 873, Processing Time 0.033 seconds

Filtration Efficiency of Granular Activated Carbons to Polydisperse Ultrafine Particles through the Surface Adsoprtion (그래뉼 타입 활성탄 필터의 100 나노 미만 다분산 초미세먼지 표면흡착 제거 효율 연구)

  • Cho, Kyungil;Kang, Giwon;Shin, Jiyoon;Kim, Changhyuk
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.79-86
    • /
    • 2022
  • Many commercial air purifiers currently have deployed granular activated carbon (GAC) filters for removing volatile organic compounds in the indoor air. GACs are generally used to remove gaseous contaminants in the air through adsorption by the inner surfaces of pores. In addition, airborne particles can be also filtered by the surface adsorption of the GACs, which can improve the life-time of the particulate filters. In this study, the filtration efficiency of GACs to ultrafine particles through surface adsorption was investigated at different volume flow rates by deploying a continuous particle filtration system. The polydisperse sodium chloride (NaCl) particles were generated by a set of an atomizer and a diffusion dryer, and then mixed with particle-free air at different volume flow rates. The penetration of ultrafine particles and pressure drop for each experimental condition were measured to figure out the effect of the volume flow rate on the surface adsoprtion of the GACs to particles, ~ 2 mm. The particle filtration efficiency of the GACs decreased as the volume flow rate increased from 4 to 14 lpm. However, the 5 times thicker GAC filter layer decreased the penetration of ultraparticles than a preious study. The filtration efficiency of the single granule was also higher than the previous result in the literature with smaller granule filter materials.

Characteristics of Dual Transverse Injection in Supersonic Flow Fields I-Mixing Characteristics (초음속 유동장 내 이중 수직분사의 특성에 관한 연구 I-혼합특성)

  • Shin, Hun-Bum;Lee, Sang-Hyeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.6
    • /
    • pp.53-60
    • /
    • 2002
  • Based on the analyses of the single transverse injection in supersonic flow fields, the mixing characteristics of dual transverse injection of hydrogen in supersonic air flow are studied with computational methods. Three-dimensional Navier -Stokes and the k-$\omega$ SST turbulence model were used. A parametric study is conducted with the variation of the distance between two injectors. The flow patterns and the mixing characteristics of two injection flows are very different from each other, and the flow patterns and the mixing characteristics of the rear injection flow are strongly influenced by those of the first injection flow. The increase of the distance between two injectors up to a specific distance results in the increase of mixing rate and penetration of fuel. However, the increase of the distance over the specific distance results in the decrease of mixing rate and penetration of fuel. From the results it can be stated that there exists a distance between two injectors for optimum mixing characteristics.

Drying Characteristics of Squids According to Far Infrared and Heated Air Drying Conditions (원적외선과 열풍 건조조건에 따른 오징어의 건조특성)

  • Kang, Tae-Hwann;Hong, Hyun-Gi;Jeon, Hong-Young;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.109-115
    • /
    • 2011
  • Drying characteristics of squids under two dry conditions were investigated using far infrared and heated air. Dry temperatures of 40, 50 and $60^{\circ}C$ with air speed of 0.6, 0.8 and 1.2 m/s were used for evaluating far infrared squid drying. Heated air squid drying at 40 and $50^{\circ}C$ with air speed of 0.8 m/s was used as a control treatment. The two drying were evaluated in terms of drying rate, color, TBA value, aerobic bacteria, cutting shear, penetration strength, and energy consumption. The drying rate of far infrared drying was relatively faster than that of heated air drying. The drying time of far infrared drying was reduced as the drying temperature increased. The color difference of far infrared dried squids was from 18.81 to 22.85, and heated air dried squid had the color different from 23.94 to 24.09. Far infrared dried squid had relatively smaller TBA values that indicate a level of rancidity. The aerobic bacteria of heated air dried squid increased from $970{\times}10^3$ to $40,000{\times}10^3$ CFU/g before and after drying, respectively. Far infrared dried squid had relatively smaller increase (from $970{\times}10^3$ to $40,000{\times}10^3$ CFU/g). The cutting shear and penetration strength for far infrared dried squids was relatively lower. In addition, far infrared squid drying consumed relatively less energy compared to heated air drying.

Transmission Dose Measurement of Gamma-ray Using Tungsten Shield (텅스텐 차폐체의 감마선 투과선량 측정)

  • Han, Sang-Hyun;Koo, Bon-Yeoul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.124-129
    • /
    • 2018
  • This study was conducted to investigate the penetration dose and shielding rates of tungsten shields used in apron material by changing the type of source used in the nuclear medicine department, thickness of shielding material and distance between the source and detector. For the experiment, the source, shield, and detector were arranged in a straight line and measured with an inspector at a height of 100 cm. The highest shielding effect of tungsten was measured for $^{201}Tl$, while $^{123}I$ showed a higher shielding effect than $^{99m}Tc$. For the sources used in the experiment, the penetration dose decreased with distance and the shielding rate was measured with thicker thickness. However, the shielding rate of $^{13}1I$ and $^{18}F$ sources was found to be lower than when there was no shielding at 0.25 mmPb shield. Therefore, even if the radiation shielding effect of tungsten is high, considering the characteristics according to the type of source and the thickness of the shielding material, it may be helpful to reduce the exposure.

Development of the Experimental Apparatus to Measure a Pore Size of Micro-pore Fabrics Used for a Bedding to Block the House Dust Mite Allergen (집먼지 진드기 알레르겐 차단 침구에 사용되는 극세 공극 직물의 공극 측정을 위한 입자 투과 실험 장치의 개발)

  • Kim, Donhue
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.557-563
    • /
    • 2022
  • In order to measure the allergen penetration of micropore fabrics, it is necessary to develop a convenient and appropriate experimental method for measuring a pore size of micropore fabrics. In this study, a simple and economical experimental apparatus was developed for the analysis of the pore size of micropore fabrics by measuring the weight reduction rate. In addition, the allergen blocking properties was evaluated by measuring the pore sizes of various fabrics. According to this study, the size of the pores of the microporous fabric could be obtained by measuring the weight reduction rates. In addition, higher weight reduction rate was obtained as the suction pressure passing through the particle permeation device decreased and the suction time was increased. It is expected that the developed experimental method and apparatus can be utilized as an experimental standard for quality control methods to verify the effectiveness of micropore fabrics used for house dust mite blocking bedding.

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF

Preparation of Diabetic Diagnostic Membranes with Phenoxy-Carboxylatophenoxy Cosubstituted Polyphosphazenes (페녹시기와 카르복시레이토페녹시기가 함께 치환된 포스파젠 고분자를 이용한 당뇨병 진단막의 제조)

  • Kwon, Suk-Ky
    • Membrane Journal
    • /
    • v.27 no.2
    • /
    • pp.138-146
    • /
    • 2017
  • The new types of phenoxy-carboxylatophenoxy cosubstituted polyphosphazene were synthesized with various substitution rates. Diabetic diagnostic membranes were prepapared with these types of polyphosphazenes and final absorbances at 680 nm through these membranes were measured at various concentrations of glucose in blood. Basically, the end-point results of varying absorbance values according to time (K/S) had a linear relationship to the glucose concentration. The effects of substitution rates with hydrophilic carboxylatophenoxy groups and hydrophobic phenoxy groups on the glucose concentration measurements were examined. It was very difficult to measure glucose concentration in less than 10% of the hydrophilic substitution rates, because the glucose penetration rate was too slow. But dose-response slope (DRS) values between glucose concentration and K/S values increased as the hydrophilic substitution rates increased in more than 10% of the hydrophilic substitution rates. However, in more than 30% of the hydrophilic substitution rates, DRS value was too rapidly increased, because glucose penetration rate was too fast.

Analysis of Technical Trend for Drilling ROP Optimization with Artificial Intelligent (인공지능을 적용한 시추 굴진율 최적화 기술 동향 분석)

  • Jung, Ji-hun;Han, Dong-kwon;Kim, Sang-ho;Yoo, In-hang;Kwon, Sun-il
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.1
    • /
    • pp.66-75
    • /
    • 2020
  • Drilling operation is the most important and costly essential work in oil and gas exploration and development. Therefore, the studies about rate of penetration have been carried out continuously to improve drilling efficiency. In recent years, data-driven models have been developed by various researchers to overcome disadvantages of traditional mathematical models. For the data-driven models, selecting proper algorithms and parameters is very important. In addition, data-driven models should be retrained in real-time during continuous drilling operations in order to improve the model performance. In this paper, the latest studies are investigated to provide information about algorithms, drilling parameters and model retraining intervals that used in drilling optimization.

Growth Characteristics of Atractylodes japonica Koidz. in its Native Habitat (삽주의 자생지 환경과 생육 특성)

  • Park, Jeon-Min;Jang, Key-Hyun;Lee, Seong-Tae;Song, Gune-Woo;Kang, Jin-Ho
    • Korean Journal of Medicinal Crop Science
    • /
    • v.8 no.4
    • /
    • pp.327-333
    • /
    • 2000
  • This study was carried out to obtain the basic information for effective conservation and cultivation of Atractylodes japonica Koidz. The soil texture was sandy loam with low pH and high organic matter content compared to general cultivative land. Aerial part growth such as plant height, number of leaf, leaf length and leaf width was the highest in Tongyong indigenous species, but fresh rhizome weight was the highest in Pyongchang. Frequency of light penetration rate was high at $60{\sim}80%$ of full sun-light, but growth was better in high light penetration rate. The correlation between growth characteristics and habitat environment were investigated in 59 districts. Correation among growth characteristics in habitat, fresh rhizome weight was significant with plant height, number of leaf and stem diameter.

  • PDF

Assessment of Penetration Performance and Optimum Design of Shaped Charge Device for Underwater Steel Cutting (수중 강재절단을 위한 성형폭약 장치 최적설계 및 관입성능 평가)

  • Ko, Young-Hun;Kim, Seung-Jun;Kim, Jung-Gyu;Yang, Hyung-Sik;Kim, Hee-Do;Park, Hoon;Noh, You-Song;Suk, Chul-Gi
    • Explosives and Blasting
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • In this study, several underwater steel cutting tests and AUTODYN numerical analyses were conducted to evaluate the penetration performance of a shaped charge device. Parameter analyses for the contribution rate were conducted by using the robust design method. The parameters adopted in this study were chamber type, stand-off, and wire setting, each of which had three levels in the analysis. Analysis results showed that the contribution rate was most affected by the stand-off, followed by the chamber type and wire setting. Experiments of underwater steel cutting were conducted at water depth of 25m. As expected, the experiments and numerical simulation showed similar results for underwater steel cutting performance, and thus the feasibility of the shaped charge device for underwater steel cutting at deep water depth was verified.