• Title/Summary/Keyword: Rate of heat consumption

Search Result 297, Processing Time 0.024 seconds

Attachment of the Air Heat Exchanger for COP Improvement in the Heat Pump (열펌프 성능향상을 위한 공기 열교환기 부착효과)

  • 노정근;송현갑;박용규
    • Journal of Biosystems Engineering
    • /
    • v.27 no.3
    • /
    • pp.235-240
    • /
    • 2002
  • Performance of the heat pump with attaching an air heat exchanger was investigated in the heating condition when the air heat exchanger was worked in the ambient air temperature of -5 to 11$\^{C}$ and air flow rate of 542 to 747 ㎡/h. Performance tests for heating condition were conducted in an experimental room equipped with heat pump. The performance tests were performed in a ambient temperature of -4 ∼ 11$\^{C}$, and room temperature of 4∼22$\^{C}$ respectively. Measured data(temperature, capacity of heat transfer and consumption of electronic power) were analyzed to the efficiency of HEEVA(Heat Exchanger fur the Evaporator), overall heat transfer coefficient and COP of heat pump. The results of inlet temperature for evaporator increased that the temperature was 2 ∼6$\^{C}$, and inlet temperature for condenser decreased that the temperature was 3 ∼ 8$\^{C}$. The results of comparing efficiency of HEEVA for the ratio of heat exchange between hot air and cold air showed that efficiency were considered to 91% because of the ratio of 83∼98%. The results of comparing of COP for the heat pump increased that improvement COP was approximately 0.3∼7.5 than HEEVA had not been operated.

Numerical Analysis on the Performance of a Outdoor Air Cooled Heat exchanger for Cooling Tower (외기이용 하이브리드 냉각탑 성능해석)

  • Kim, Sung-Il;Lee, Wook-Hyun;Lee, Kye-Jung;Chun, Won-Pyo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2322-2327
    • /
    • 2008
  • This paper is to provide analysis model that can be used to investigate the improvement in energy efficiency for cooling tower by using fresh air. Numerical analysis of Air-cooled heat exchanger for single-phase flow with variations of outdoor air temperature has been performed. A complete set of correlations of the heat transfer in both refrigerant and air sides was employed for predicting the heat transfer rate. The numerical results derived from the correlations were verified with experimental results. The energy consumption for a hybrid cooling tower has been compared for variation of a outdoor air temperature. The results showed that the hybrid cooling tower in low outdoor temperature offers a significant improvement in energy efficiency. The thermal analysis aids significantly in the solution of the design problem of hybrid cooling tower.

  • PDF

Minimization of Energy Consumption for Amine Based CO2 Capture Process by Process Modification

  • Sultan, Haider;Bhatti, Umair H.;Cho, Jin Soo;Park, Sung Youl;Baek, Il Hyun;Nam, Sungchan
    • Journal of Energy Engineering
    • /
    • v.28 no.4
    • /
    • pp.13-18
    • /
    • 2019
  • The high energy penalty in amine-based post-combustion CO2 capture process is hampering its industrial scale application. An advanced process is designed by intensive heat integration within the conventional process to reduce the stripper duty. The study presents the technical feasibility for stripper duty reduction by intensive heat integration in CO2 capture process. A rigorous rate-based model has been used in Aspen Plus® to simulate conventional and advanced process for a 300 MW coal-based power plant. Several design and operational parameters like split ratio, stripper inter-heater location and flowrate were studied to find the optimum values. The results show that advanced configuration with heat integration can reduces the stripper heat by 14%.

The Effect of Vitamin E and Vitamin C on the Performance of Japanese Quails (Coturnix Coturnix Japonica) Reared under Heat Stress during Growth and Egg Production Period

  • Ipek, A.;Canbolat, O.;Karabulut, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.2
    • /
    • pp.252-256
    • /
    • 2007
  • This study was carried out to determine the effect of vitamin E and vitamin C on the performance of Japanese quails (Coturnix coturnix japonica) reared under heat stress during the growth and egg production period. A total of 810 seven-day-old Japanese quails were used in the trial. The birds received a diet with either three levels of vitamin E (DL-${\alpha}$Tocopheryl acetate) (60, 120 and 240 mg/kg of diet) and vitamin C (ROVIMIX STAY-C 35) (60, 120 and 240 mg/kg of diet). Live weight on day 35 and weight gain were the lowest in the group of chicks on a combination of 60 mg of vitamin E and 60 mg of vitamin C, whereas the highest live weight was demonstrated in chicks on a combination of 240 mg of vitamin E and 240 mg of vitamin C (p<0.01). The effects of treatments on cumulative feed consumption, feed conversion ratio, age at 5% lay, sexual maturity weight, rate of lay and mean egg weight values were found to be significant (p<0.01). The highest feed consumption, feed conversion ratio, age at 5% lay, sexual maturity weight, rate of lay and mean egg weight values were found in the group on a combination of 240 mg of vitamin E and 240 mg of vitamin C. The effect of treatments on the mortality ratio was found to be insignificant (p>0.01). The cost of supplementing diets with vitamin E and vitamin C is very low. Therefore such a combination of supplement can offer a potential protective management practice in preventing heat stress related losses in performance of Japanese quails.

TURBULENCE HEAT TRANSFER ENHANCEMENT TECHNIQUE FOR SQUARE DUCT WITH HIGH ASPECT RATIO (종횡비가 큰 사각 덕트내 난류 유동의 대류 열전달 증진 기술에 대한 연구)

  • Lee, Chan-Yong;Shin, Seung-Won;Chung, Ha-Seung;Park, Seung-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.305-307
    • /
    • 2010
  • In this study, we develop a method to achieve heat transfer enhancement inside a square duct with high aspect ratio without changing any inner structures. Especially, a method to lower the possible maximum temperature is suggested if constant heat flux is provided to single surface of square duct. Knowing the fact that heat transfer rate is inversely proportional to flow area, we proposed tapered channel concept which uses narrower gap toward the flow exit where the maximum temperature is expected. To maintain equivalent power consumption, inlet section has been enlarged. To verify the proposed concept, experimental tests have been performed.

  • PDF

Heat Transfer and Pressure Drop Characteristics of Cross-Flow Plastic Air Heater for a Cooling Tower (냉각탑용 직교류형 플라스틱 공기가열기의 열전달 및 압력손실)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6072-6081
    • /
    • 2013
  • In this study, experiments were performed on air heater samples with three different shapes (chevron, wave and dimple type) to reduce the plumes from cooling towers. The tests were conducted for a range of frontal air velocities of 1~3 m/s and water flow rate 0.19~0.33 kg/s. The results showed that the heat transfer rate increased with increasing air velocity or water flow rate. The air-side pressure drop also increased with increasing air velocity. At the same frontal air velocity, the highest heat transfer rate was obtained for the chevron sample (1.5~1.7 times compared to that of the plate sample), followed by the dimple, wave and plate samples. The heat transfer rate per unit power consumption was also 15% larger than that of the dimple sample. On the other hand, there was no noticeable difference between the other samples.

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.

Feasibility Study of High-Efficiency Ground Heat Exchanger using Double U-tube through a Real-Scale Experiment

  • Bae, Sangmu;Kim, Jaemin;Nam, Yujin
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.33-39
    • /
    • 2017
  • Purpose: The use of renewable energy system is essential for building energy independence and saving energy consumption in the building sector. Among renewable energy technologies, ground source heat pump(GSHP) system is more energy-efficient and environmental-friendly than other heat source systems due to utilize stable ground heat source. However, the GSHP system requires a high initial installation cost and installation space in limited urban area, so it is difficult to have superiority in the market of heat source system. Therefore, it is necessary to develop the installation method of low-cost and improve system performance. This paper aims to evaluate the performance of double u-tube ground heat exchanger(GHX) and verify system feasibility through real-scale experiment. Method: In this study, the real-scale experiment of vertical closed-type GSHP system was conducted using double u-tube GHX and high-efficiency grout. Through the verification experiment, heat source temperature, heat exchange rate(HER) and seasonal performance factor(SPF) were measured according to the long-term operation. In addition, the feasibility analysis was conducted comparing to the single u-tube system. Result: In the results of experiment, average HER was 136.27 W/m and average SPF was 5.41. Furthermore, compared to the single u-tube, the installation cost of the developed system could be reduced about 70% in the same heating load condition.

A Numerical Study for Design Optimization of Nozzle Injection Angle in Tenter Machine (텐터기 노즐 분사각의 최적설계를 위한 수치해석적 연구)

  • Chun, Du Hwan;Park, Si Woo;Kim, Jung Han
    • Textile Coloration and Finishing
    • /
    • v.25 no.2
    • /
    • pp.134-139
    • /
    • 2013
  • A tenter is very important to dry and heat-set fabrics in textile dyeing and finishing industry. However, the tenter machine typically utilizes more than 80% of all the power in dyeing system, and yet is one of the primary machine which affects quality of fabrics. Therefore, performance optimization of the tenter machine is required to reduce energy consumption and enhance quality of fabrics. To optimize the tenter machine, it is important to maintain the uniform flow rate, which can be obtained by optimizing a nozzle geometry. In this study, emboss hole angle was investigated as main parameter in flow rate uniformity and heat flux efficiency. The analysis results were compared with those acquired from bench-scale dryer test in the laboratory. The tenter machine performance simulated by Computational Fluid Dynamics(CFD) was optimized by controlling emboss hole angle.

The Effect of EGR on Exhaust Emissions in a Direct Injection Diesel Engine (직분식 소형 과급 디젤엔진에서 EGR이 배기배출물에 미치는 영향)

  • Jang, Se-Ho;Koh, Dae-Kwon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.188-194
    • /
    • 2005
  • The direct injection diesel engine is one of the most efficient thermal engines. For this reason DI diesel engines are widely used for heavy-duty applications. But the world is faced with very serious problems related to the air pollution due to the exhaust emissions of diesel engine. So, that is air pollution related to exhaust gas resulted from explosive combustion should be improved. Exhaust Gas Recirculation(EGR) is a proven method to reduce NOx emissions. In this study, the experiments were performed at various engine loads while the EGR rates were set from $0\%$ to $30\%.$ The emissions trade-off and combustion of diesel engine are investigated. The brake specific fuel consumption rate is very slightly fluctuated with EGR in the range of experimental conditions. The ignition delay increased with increasing EGR rate. The maximum value of premixed combustion for the rate of heat release is increased with increasing EGR rate. NOx emissions are decreased with increasing EGR rate at high load and high speed. It was found that the exhaust emissions with the EGR system resulted in a very large reduction in oxides of nitrogen at the expense of higher smoke emissions.