• Title/Summary/Keyword: Rate Test

Search Result 13,470, Processing Time 0.042 seconds

An Analysis on the Causal Relation Among SMP, Base-Load Share, LNG Import Price, and Exchange Rate (전력계통한계가격(SMP)과 기저발전비율, LNG도입가격, 환율 간 인과관계 분석)

  • Park, Min Hyug;Moon, Yang Taik;Park, Jung Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.97-105
    • /
    • 2014
  • This article examines the causality relationship among SMP, base-load share, LNG import price, and exchange rate in Korean power market during 2002~2012, using unit root test, cointegration test, and vector error correction model(VECM). The cointegration test shows that 4 variables without unit root have been in the long-run causality. As the results of ECM, SMP is analyzed to have been unilaterally caused from LNG import price and base-load share in the shot-run, while it has been unilaterally caused from LNG import price and exchange rate in the long-run. This article has the following policy implications: the adjustment of exchange rate to reduce he risk of LNG import price and the proper securement of base-load share for the long-run stability of SMP.

Day-of-the-Week Effect of Exchange Rate in Developing Countries

  • ANWAR, Cep Jandi;OKOT, Nicholas;SUHENDRA, Indra
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.2
    • /
    • pp.15-23
    • /
    • 2021
  • This study investigates the presence of the day-of-the-week anomaly in exchange rate for 30 developing countries with free floating exchange rate regimes using daily data from January 2, 2011 to December 31, 2019. First, we apply the GARCH panel to estimate the intraday effect for all the sampled countries. Second, we run poolability test to check whether the coefficients of the GARCH panel are the same for all countries sampled. The result of poolability test rejects the homogeneity assumption. This implies that our sample countries contain heterogeneity. Third, we apply mean-group estimation by averaging the coefficients for all individual GARCH estimations. Fourth, we divided our sample of developing countries into three groups based on capital restriction index for the reason that the effect of monetary policy on the exchange rate depends on the degree of capital account liberalization. The empirical evidence for the return equation suggests that Mondays are connected with lower volatility whereas Thursdays experiences higher return compared to Tuesdays. The lowest estimated coefficient for full sample, group 1 and group 2, is Friday, but for group 2 is Thursday. We find similar result for the volatility equations, which show that Monday returns are lower compared to Tuesday.

An Analysis of Combustion Characteristics of Residential Facilities through Real Fire Tests in a Small Residential Space (소규모 주거 공간 실물화재실험을 통한 적재 가연물의 연소특성 분석)

  • Yang, So Yeon;Moon, Min Ho;Won, Jeong Hun
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.73-79
    • /
    • 2022
  • In this study, real fire tests were performed on representative combustibles of residential facilities to analyze the fire behavior and combustion characteristics in a small residential space. The considered combustibles were a sofa, a combination of a desk and a chair, and a combination of a mattress and an electric mat. A compartment space fire test was performed using the room corner test equipment prescribed in the KS F ISO 9705 specification. Three real fire tests were conducted by placing the combustible material inside a small compartment with insulation and finishing materials and by igniting the combustible material. Results showed that the peak heat release rate and peak smoke production rate occurred in the combination of the mattress and electric mat. Furthermore, from the result of the fire rate analysis, it was estimated that the fire risk of the mattress and electric mat combination was the highest, followed by the sofa and thedesk and chair combination.

Development of Evaluation Technique of High Temperature Creep Characteristics by Small Punch-Creep Test Method (I) - Boiler Superheater Tube - (SP-Creep 시험에 의한 고온 크리프 특성 평가 기술 개발(I) - 보일러 과열기 튜브 -)

  • Baek, Seung-Se;Na, Seong-Hun;Na, Ui-Gyun;Yu, Hyo-Seon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.1995-2001
    • /
    • 2001
  • In this study, a small punch creep(SP-Creep) test using miniaturized specimen(10${\times}$10${\times}$0.5mm) is described to develop the new creep test method for high temperature structural materials. The SP-Creep test is applied to 2.25Cr-lMo(STBA24) steel which is widely used as boiler tube material. The test temperatures applied for the creep deformation of miniaturized specimens are between 550∼600$^{\circ}C$. The SP-Creep curves depend definitely on applied load and creep temperature, and show the three stages of creep behavior like in conventional uniaxial tensile creep curves. The load exponent of miniaturized specimen decreases with increasing test temperature, and its behavior is similar to stress exponent behavior of uniaxial creep test. The creep activation energy obtained from the relationship between SP-Creep rate and test temperature decreases as the applied load increases. A predicting equation or SP-Creep rate for 2.25Cr-lMo steel is suggested. and a good agreement between experimental and calculated data has been found.

Development of High Temperature Creep Properties Evaluation Method using Miniature Specimen (미소시험편을 이용한 고온 크리프 특성 평가법 개발)

  • Yu, Hyo-Sun;Baek, Seung-Se;Lee, Song-In;Ha, Jeong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.43-48
    • /
    • 2000
  • In this study, a small punch creep(SP-Creep) test using miniaturized specimen$(10{\times}10{\times}0.5mm)$ has been described for the development of the newly semi-destructive creep test method for high temperature structural components such as headers and tubes of boiler turbine casino and rotor and reactor vessel. The SP-Creep testing technique has been applied to 2.25Cr-1Mo(STBA24) steel used widely as boiler tube material and the creep test temperature are varied at $550^{\circ}C{\sim}600^{\circ}C$. The overall deformations of SP-Creep curves are definitely depended with applied load and creep test temperature and show the creep behaviors of three steps like conventional uniaxial creep curves. The steady state creep rate${\delta}_{ss}$ of SP-Creep curve for miniaturized specimen increases with increasing creep temperature, but the exponential value with creep loading is decreased. The activation energy$(Q_{spc})$ during SP-Creep deformation with various test temperatures shows 605.7kJ/mol that is g.eater than 467.4kJ/mol reported in uniaxial creep test. This may be caused by the difference of stress states during creep deformation In two creep test. But from the experimental results, e.g. SP-Creep curve behaviors, the steady state creep rate${\delta}_{ss}$ with creep temperature, and the exponential value(n) with creep loading, it can be summarized that the SP-Creep test may be a useful test method to evaluate the creep properties of the heat resisting material.

  • PDF

Association of Metabolic Syndrome with Exercise Capacity and Heart Rate Recovery after Treadmill Exercise Test

  • Shin, Kyung-A
    • Biomedical Science Letters
    • /
    • v.17 no.4
    • /
    • pp.305-311
    • /
    • 2011
  • Heart rate recovery (HRR) immediately after a treadmill exercise test is a function of vagal reactivation. A delayed heart rate recovery is associated with an increased risk for overall cardiovascular mortality. The purpose of this study is to find out if metabolic syndrome is associated with autonomic nerve function and exercise capacity in healthy adults. We measured the treadmill exercise capacity (METs) and heart rate recovery in 119 subjects through a medical checkup at $J$ General Hospital. The metabolic syndrome was defined according to the National Cholesterol Education Program Adult Treatment Panel III (NCEP-ATP III) criteria. The value for the HRR was defined as the difference between the heart rate obtained during the peak exercise and the heart rate obtained at first minute during the recovery period. The subjects with the metabolic syndrome had significantly lower exercise duration ($9.6{\pm}1.5$ vs $8.7{\pm}1.4$), METs ($11.6{\pm}1.7$ vs $10.4{\pm}2.5$), and HRR ($37.5{\pm}14.3$ vs $27.1{\pm}8.9$). The waist circumference in subjects with the metabolic syndrome was more strongly correlated with HRR ($r$=-.517, $P$ <.001) than in normal subjects. Furthermore, delayed HRR was associated with high resting heart rate and increased waist circumference ($P$=.032, $P$ <.001, respectively). In conclusion, delayed HRR during the first minute after a treadmill exercise test was associated with the metabolic syndrome risk factors. Delayed HRR was also associated with high resting heart rate and increased waist circumference.

Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance (터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구)

  • Sohn, Dong-Kee;Kim, Chun-Tak;Yoon, Min-Soo;Cha, Bong-Jun;Kim, Jin-Han;Yang, Soo-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF

Stress Corrosion Cracking Susceptibility Evaluation by Small Punch Test (소형펀치시험법에 의한 응력부식균열 감수성평가에 관한 연구)

  • 유효선;이송인;정세희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.8
    • /
    • pp.2033-2042
    • /
    • 1993
  • In conventional SCC susceptibility test, there are constant strain test, constant load test, slow strain rate test(SSRT) and K$_{ISCC}$ test. Among them, the SSRT method is much more aggressive in producing SCC than the other tests, so that the test time of it is considerably reduced. But this SSRT method has mostly been worked using the uniaxial tensile specimen untill now. Therefore, the SSRT method using the tensile specimen(Ten-SSRT) has much difficulty in SCC susceptibility evaluation of a localized region like weldment and the advantage material of high order. Recentely, the small punch(SP) test method using miniaturized small specimen is the very effective test method for fracture strength evaluation of a localized region like weldment and fusion reactor wall irradiated in the nuclear power plant. This paper investigated the possibility of SCC susceptibility evaluation by the SP-SSRT method using the miniaturized small specimen. Therefore, we obtained the result that the SP-SSRT had the possibility for the evaluations of SCC susceptibility for shorter time to corrosive environment compare to Ten-SSRT which was conventional method.

Comparison of LAL Test with Pyrogen Test (발열성 물질시험과 세균 내독소 시험의 비교 연구)

  • 이유경;강윤숙;백선영;김용관;신광훈;민홍기
    • YAKHAK HOEJI
    • /
    • v.43 no.5
    • /
    • pp.606-613
    • /
    • 1999
  • To survey the possibility of replacing the pyrogen test with Limulus Amebocyte Lysate(LAL) test and to find out a standard methods suitable to our blood products made in Korea, 100 samples of 20% human serum albumin were tested by commercial LAL test kits and results of those were compared with rabbit pyrogen test. The LAL test is used both dinetic-chromogenically and kinetic-turbidimetrically. Both methods equally showed broad detection range (5.0~0.005 EU/ml), excellent sensitivity ($\geq$ 0.005 EU/ml) and predominant recovery rate within valid dilution range, but kinetic-turbidimetric method seemed to be more reproducible than kinetic-chromogenic method(kinetic-chromogenic method : S.D. = 15.88, kinetic-turbidimetric method : S.D. = 8.12). After heating the sample at 75$^{\circ}C$ for 15 min, the results showed a little elevated recovery rate with both methods. After performing the test on 100 albumin samples with both kits, the results were analysed using the USP standard (1.33 EU/ml). 7% of samples in kinetic-chromogenic methods and 1% of samples in kinetic-turbidimetric method exceeded the limit of endotoxin levels regulated for blood products in USA. Because this phenomenon was not observed in both methods at the same time and both methods have high sensitivity ($\geq$0.005 EU/ml), these results seemed to depend on nonspecific reaction. Considering its sensitivity and reproducibility, we could assure that LAL test is proper to detecting pyrogenic with good sensitivity.

  • PDF

The Dyeing Properties and The Functionality of Fabrics Dyed with Chelidonium Majus Extract (백굴채 추출물을 이용한 염색직물의 염색성 및 기능성)

  • Park, Young-Hee
    • Fashion & Textile Research Journal
    • /
    • v.10 no.2
    • /
    • pp.242-248
    • /
    • 2008
  • This study was aimed to find whether the Chelidonium majus which grows naturally in Korean soil and has a various medical ingredient is valuable as a natural dyeing material and to examine the functionality of Chelidonium majus extract. As the test result of dyeing colorfastness, colorfastness to sunlight was 1st grade for all the dyed fabrics. The colorfastness to laundry for discoloration showed from 1st to 4th grade and that for discoloration showed from 4th to 5th grade through all the dyed fabrics. Colorfastness to perspiration, rubbing, and drycleaning showed from 4th to 5th grade through all the dyed fabrics. In the result of antibiosis test, the dyed cotton fabric showed the bacteria reduction rate of 99.0% for Staphylococcus aureus and Escherichia coli evenly when washed one, three, and five times, The dyed silk fabric, when washed one, three, and five times, showed the bacteria reduction rate of 99.0% for Staphylococcus aureus, but didn't showed the significant bacteria reduction. As the test result of sun protection test, in the case of the cotton fabric which was dyed but don't use mordant, after one-time washing, S.P.F.(Sun Protection Factor) showed 20.4, the interception rate of UV-A showed 94.3%, and that of UV-B showed 95.2%. After five-time washing, S.P.F. showed 14.3, the interception rate of UV-A showed 90.0%, and that of UV-B showed 93.2%. In the case of the silk fabric which was dyed but don't use mordant, after one time washing, S.P.F. showed 30.5, the interception rate of UV-A showed 95.9%, and that of UV-B showed 96.9%, after five-time washing, S.P.F. showed 31.0, the interception rate of UV-A showed 95.6%, and that of UV-B showed 96.7%.